Go to page of
Similar user manuals
-
Switch
3Com DUA1711-1AAA01
8 pages 0.79 mb -
Switch
3Com C17304
84 pages 5.7 mb -
Switch
3Com 100 TX
64 pages 1.04 mb -
Switch
3Com 800
8 pages 0.77 mb -
Switch
3Com SuperStack 3 4900 SX
54 pages 2.34 mb -
Switch
3Com 3C16897 8-slot DC Chassis
80 pages 2.13 mb -
Switch
3Com 3CR17662-91
104 pages 2.8 mb -
Switch
3Com Baseline 2848-SFP Plus
5 pages 0.04 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of 3Com 8800, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of 3Com 8800 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of 3Com 8800. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of 3Com 8800 should contain:
- informations concerning technical data of 3Com 8800
- name of the manufacturer and a year of construction of the 3Com 8800 item
- rules of operation, control and maintenance of the 3Com 8800 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of 3Com 8800 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of 3Com 8800, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the 3Com service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of 3Com 8800.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the 3Com 8800 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
3Com ® Switch 8800 Power Over Ether net Installation Guide www.3Com.com Part Number: 10015270 Rev. AA Published: July 2006[...]
-
Page 2
3Com Corporation 350 Campus Drive Marlbor ough, MA USA 01752-3064 Copyright © 2006, 3Com Corporati on. All rights reserv ed. No part of this documentation may be r eproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Corpo ration. 3Com Co[...]
-
Page 3
C ONTENTS 3 C ONTENTS 1 I NTRODUCTION Switch 8800 PoE Power Rack 5 Features 5 Architectur e and Configurations 5 2 S YSTEM D ESCRIPTION Overview 9 Power Supply Modules 9 PoE Power Rack 9 Power Supply Mo dule Visual indicators 10 System Controller 10 Distribution Panel 12 3 S AFETY Safety Statements 13 W arning Statements and Safety Symbols 13 Preca[...]
-
Page 4
4 C ONTENTS[...]
-
Page 5
1 I NTR ODUCTION Switch 8800 PoE Power Rack The 3Com Switch 8800 PoE power rack is a modular , stand-alo ne Power over Ether net (PoE) power sour ce. The PoE Power Rack provides a total of 4500 W atts of DC power with 2+1 power redundancy for PoE powered devi ces connected to the Switch 8800 chas sis. Features The PoE Power Rack has the following f[...]
-
Page 6
6 C HAPTER 1: I NTRODUCTION Figure 1 The PoE Power Rack Figure 2 The PoE Power Rack (Rear View) Refer to F igur e 3 for the fron t view of a f ully equippe d PoE power rack. It consist s of: ■ System controller with 2 LEDs and 3 co nnectors ■ Distribution panel with DC output sockets and three AC input sockets ■ Power supply modules (3 module[...]
-
Page 7
Architecture and Conf igurations 7 Figure 3 The PoE Power Rack Configur ed with Three Power Supply Modules (Fr ont VIew)[...]
-
Page 8
8 C HAPTER 1: I NTRODUCTION[...]
-
Page 9
2 S YSTEM D ESCRIPTION Overview Figur e 4 shows the schematic diagra m of the PoE Power Rack power system, showing the interconnections and signal flow through the power supply modules and inter nal components. Figure 4 Schematic Diagram of the PoE Power Rack Power Supply Modules DC power is supplied to the power bus by the power supply modules. Th[...]
-
Page 10
10 C HAPTER 2: S YSTEM D ESCRIPTION Power Supply Module Visual indicators The front panel of the power supply module has three LEDs (Figur e 5). Their descriptions, colors, and functions ar e sho wn in Ta b l e 2. System Controller The PoE Power Rack has a system contr oller at the front of the chassis. Refer to Figur e 6 . Figure 6 Fr ont Panel of[...]
-
Page 11
System Controller 11 ■ Monitor system operation status - An AC sensor card inside the PoE Power Rack samples the AC input voltage. The sampled signal is sent to the controller for processing. If the AC input voltage is lower than the pre-set al arm level, the controller r eports an AC input under -voltage alarm. Likewise, if the input voltage is [...]
-
Page 12
12 C HAPTER 2: S YSTEM D ESCRIPTION Distribution Panel The distribution p anel consists of DC out put sockets and three AC input sockets. Refer to Figure 7. Figure 7 Distribution Panel The three EN60320 C20 AC input sockets on the front panel of the device ar e rated at 20A@250V AC. Each socket supplies power to one power supply modu le. Ther e is [...]
-
Page 13
3 S AFETY Safety Statements Please read and follow a ll sa fety instructions and warnings before servicing the PoE Power Rack. Refer to the individual module product manuals fo r additional safety statements specific to the modules. ■ The device must be in a restricted access area (dedicated equipment rooms, equipment closets, etc.) where the app[...]
-
Page 14
14 C HAPTER 3: S AFETY electrical equipment and who understand the hazards that can arise when working on this equipment. ■ The PoE Power Rack can be powered by multiple AC inputs, ensure that the appropriate cir cuit protection device for each AC input being serviced is disconnected before changing or servicing a Power Suppl y Module. If servici[...]
-
Page 15
4 I NSTALLATION AND TESTING Introduction This section outlines the sequence for inst alling the PoE Power Rack, including plug-in modules. T est procedures for verifying th e integrity of the installation are also included. Guidelines The device must be installed to allow sufficient front and r ear access. All cables must be routed thr o ugh insula[...]
-
Page 16
16 C HAPTER 4: I NSTALLATION AND TESTING Install the PoE DIMM Module If you are installing the opt ional PoE DIMM module, use the following instructions. T echnical Specifications The technical specific ations of PoE DIMM (Dual In-lin e Memory Module) ar e listed in Ta b l e 5. Install the PoE DI MM Module Wear a n ESD-protective wrist strap wh en [...]
-
Page 17
Installation Sequence 17 3 The following items are included in the unit packaging: PoE Power Rack, power supply module, dummy faceplates and cabl es. Remove al l this material and place aside. Mounting screws ar e NOT supplied with th e PoE Power Rack. Moun ting screws may be obtained from t he equi pment rack/cabinet supplier . 4 It is your option[...]
-
Page 18
18 C HAPTER 4: I NSTALLATION AND TESTING Install Power Supply Modules Power Supply Modules are installed by slid ing into the power rack, pu shing until the power supply module is fully inserted , and closing the handle on the power supply module. Refer to Figure 10 . 1 V erify that the AC power switches on the AC distribution panel are in the &quo[...]
-
Page 19
Installation Sequence 19 Connecting to AC utility/ AC groun ding AC power input is accessed from the front of the unit. AC power cord connection is made using power cords with IEC 60320 C- 19 connector plugs. The AC pow er plugs are labeled Input 1, Input 2, and Input 3, which corr espond to the power supply modules numbered fr om le ft to right. R[...]
-
Page 20
20 C HAPTER 4: I NSTALLATION AND TESTING[...]
-
Page 21
5 E NGINEERING , M AINTENANCE AND T R OUBLESHOOTING Maintenance and T roubleshooting This section pr ovides fiel d maintenance info rmation a nd tr oubleshooting procedures for the PoE Power Rack an d power supply mo dules. Review the safety information in section 3 of this manual before performing maintena nce procedur es All procedures described [...]
-
Page 22
22 C HAPTER 5: E NGINEERING , M AINTENANCE AND T ROUB LESHOOTING ALM or None -- Controller failure Replace the controller T able 6 T roubleshooting Guide Controller alarm status Power supply module display Possible pr oblems Possible so lution[...]