3M 2250E manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of 3M 2250E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of 3M 2250E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of 3M 2250E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of 3M 2250E should contain:
- informations concerning technical data of 3M 2250E
- name of the manufacturer and a year of construction of the 3M 2250E item
- rules of operation, control and maintenance of the 3M 2250E item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of 3M 2250E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of 3M 2250E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the 3M service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of 3M 2250E.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the 3M 2250E item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    September 1999 78-8097-6500-7-B Dynatel ™ 2250E/2273E Adv anced Cable and F ault Locator Operators Manual[...]

  • Page 2

    TABLE OF CONTENTS Introduction ............................................................................... 2 Installing or Replacing the Batteries ........................................ 2 Initial Receiver Conf iguration .................................................. 3 Receiver Ba ttery T est ...............................................[...]

  • Page 3

    INTRODUCTION The 3M ™ Dynatel 2250E/2273E Advanced Cable and F ault Locator consists of a T ransmitter and a Receiver for locating b uried cables or Activ e Duct Pr obes (sondes). It also measures and pinpoints sheath faults in buried cables (2273E only) and conductor f aults in aerial cables. The transmitter provides four frequencies to accommod[...]

  • Page 4

    INITIAL RECEIVER CONFIGURA TION Display depth units (inches, feet and inches, or centimeters) may be changed while holding and pressing . For each press, one of three units will display . T o change the passiv e Power frequency , press and hold then press to toggle between 50 or 60 Hz as displayed in the lo w er left corner of the display . T o cha[...]

  • Page 5

    TRANSMITTER BA TTER Y TEST T o test the Ba tteries, press and hold . Listen to the tone and watch the display . • solid tone and 'OK' indicates batteries good; • beeping tone and 'LO' indicates batteries low; • no tone and '- -' indicates replace batteries. Note: The battery test indicates battery condition for n[...]

  • Page 6

    LOCA TING A BURIED CABLE T ransmitter Setup Note: K ey descriptions can be found inside the T ransmitter lid. Perform a battery test and then connect the T r ansmitter using one of the three methods below to put tr acing signal on a cable . Page 5 Danger! V oltage higher than 240 volts will damage equipment and cause personal injury and death. Make[...]

  • Page 7

    DIRECT CONNECT METHOD Make sure the T ransmitter is off. Plug the Direct Connect Cable into the front panel jack. Connect the Black clip to the ground rod. Place the ground rod in the earth perpendicular to the suspected cable path. If necessary , extend the black lead with the Ground Extension Cable. Ne xt, remov e the ground bonding and attac h t[...]

  • Page 8

    Press to select Trace mode. Press ag ain to select one or all of the four frequencies. The display will alternate between displaying the selected frequency and the output signal current. It is best to choose the low est frequency for direct connect with far-end g round and a high frequency for direct connect with no far -end ground. Press to select[...]

  • Page 9

    DYNA-COUPLER METHOD Cable Path Page 8 Connect the Dyna-Coupler to the T ransmitter front panel jac k using the coupler cable. Clamp the Dyna-Coupler around the cable belo w any bonds just before cable enters the earth. The jaws of the coupler m ust fully close. Press to turn T ransmitter on. Press again to select 8 kHz, 33 kHz or 133 kHz. Select hi[...]

  • Page 10

    INDUCTION METHOD Place the transmitter on the ground ov er the target cable with the lid hinge in line with the cable path. Press to turn the T ransmitter on. Press again to select either 33 kHz or 133 kHz. For gr eater tracing range, select high output le vel by pressing . Note: If the Receiver is less than 15 meters fr om the T ransmitter , it ca[...]

  • Page 11

    LOCA TING A BURIED CABLE Receiv er Setup Note: K ey descriptions can be found on the side of the Receiver . Press to turn the Receiver on. Press to select the 50/60 Hz po wer frequency (see Selecting P assive P ow er F requencies, pa ge 12) or LF for passiv e locating; otherwise, select the same frequency as the Transmitter . Note: The Receiver is [...]

  • Page 12

    About T race Modes Peak: In this mode, as the antenna crosses the cable, the Receiv er speaker v olume incr eases to a maximum and the bar graph f ills fr om both sides tow ard the middle. As the antenna mov es off the cable path, the speaker v olume decreases and the bar gr aph opens. Peak with High-Expanded: While in Peak mode, press to select Hi[...]

  • Page 13

    Selecting P assive P ower F requencies See section Initial Receiv er Configuration (page 3) to set the pow er frequenc y to 50 Hz or 60 Hz. The Recei ver can be tuned to locate 3 dif ferent harmonics of the chosen power frequenc y . H50 Hz or H60 Hz (high harmonic): Best for general locating of passiv e power . L50 Hz or L60 Hz (low har monic): W o[...]

  • Page 14

    Using Current Indications During Locating Both the Transmitter and Recei ver will indicate cable current. These current indications will help to select a trace frequency , identify the correct cable and trouble shoot the set up. When using the direct connect method, the Transmitter output current number is displayed. A "LO" display , or n[...]

  • Page 15

    LOCA TING SHEA TH FA UL TS (2273E ONL Y) T r ansmitter Setup Remove both the near -end and far-end shield bonds from the test section. Perform a battery test then with the T ransmitter off, connect the Black clip to the ground rod. Place the ground rod behind the Transmitter , away from the faulted section, and in line with the cable path. If neces[...]

  • Page 16

    T o verify the fault location, insert the fr ame’ s red leg directly on the spot identified abo ve. Piv ot the frame in a circle around red leg re-inserting the green leg in ground e very few de grees of the circle. The bar graph should always be on the left (red) indicating that the fault is directly below r ed leg. After a fault is found and pi[...]

  • Page 17

    LOCA TING AN ACTIVE DUCT PROBE (ADP) Press to turn the Receiver on. Press to select the 33 kHz frequency . Press to select the Peak mode . If you find tha t the received signal is too weak in this mode, try the Special Peak mode. T o select Special Peak mode: from Peak mode, press and hold , then press to toggle between Peak and Special Peak modes.[...]

  • Page 18

    LOCA TING EMS MARKERS EMS markers may be detected and located using either the Dynatel™ 2205 or 2206 EMS Marker Locating Accessory . T o attach the accessory , slide the Recei ver horizontally into EMS Marker Locating Accessory mounting slot. Make sure the locking button holds the Recei ver securely in the slot. T o separ ate the units, press the[...]

  • Page 19

    TONING AERIAL FA UL TS T r ansmitter Setup Perform a battery test; then with the T ransmitter off, plug the direct connect cable into the front panel jack. If fault is a shorted pair , connect Red clip to tip and the Black clip to ring. If the fault is a cross (two pair in volved), connect the Red clip to crossed conductor of one pair and the Black[...]

  • Page 20

    CABLE OR PAIR IDENTIFICA TION T ransmitter Setup T ransmitter setup is the same to identify cables or pairs; howe ver , Recei ver setups are dif ferent. Perform a battery test; then with the transmitter off, connect the Dyna-Coupler to the T ransmitter front panel jack using the coupler cable. Note: Cable Identification r equires two Dyna-Coupler s[...]

  • Page 21

    PAIR IDENTIFICA TION Receiv er Setup Press to turn the Receiver on. Press to select T one mode . Connect the inducti ve probe to Recei ver accessory jack using probe cable. Press to select the highest toning frequency (133 kHz). Insert Probe into the b undle of pairs (or gr oup, if kno wn) and press . Next, di vide the pairs into two bundles and in[...]

  • Page 22

    OPTIONAL ACCESSORIES 1196 6 inch Dyna-Coupler (includes Pouch) 2200 Series Carrying Bag 2205 EMS Marker Locating Accessor y (single frequencies) 2206 EMS Marker Locating Accessor y (all frequencies) 3005 1 inch Dyna-Coupler 3011 Inductiv e Probe 3019 3 inch Dyna-Coupler Kit (includes 9011 Coupler Cable and Pouch) 3229 ADP (sonde) 9011 Coupler Cable[...]

  • Page 23

    TECHNICAL INFORMA TION T r ansmitter Frequencies: T race mode: 577 Hz, 8 kHz, 33 kHz, 133 kHz Sheath Fault mode: 10 and 20 Hz for faults and (2273E only) 577 Hz & 33 kHz for tracing T one mode: 577 Hz & 133 kHz pulsed at 8 Hz Induction mode: 33 kHz and 133 kHz Output Po wer: 3 watts maximum or 5 watts w/e xternal DC sour ce Battery Life: 50[...]

  • Page 24

    T elecom Systems Division 6801 Riv er Place Blvd. Austin, T e xas 78726-9000 Litho in USA 3M 1999 This product is in accordance with the requirements of the European directi ve 89/336/EEC Dynatel ™ is a registered trademark of 3M. Duracell ™ is a registered trademark of Duracell Inc . Important Notice All statements, technical information, and [...]