3M 34 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of 3M 34, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of 3M 34 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of 3M 34. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of 3M 34 should contain:
- informations concerning technical data of 3M 34
- name of the manufacturer and a year of construction of the 3M 34 item
- rules of operation, control and maintenance of the 3M 34 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of 3M 34 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of 3M 34, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the 3M service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of 3M 34.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the 3M 34 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    QUEST emp o 34 and QUEST emp o 36 User Manual ©3 M 20 1 3. A ll Ri ght s Res er ved 3M P ersonal Safety Division 3M ™ QUEST emp° ™ Heat Stress Monitors Market Leader F rom the Robus t C onst ruc tion F rom the[...]

  • Page 2

    i T able of Content s Table of Cont ents Introductio n ........................................................................................................................ 1 QUESTempº Model s .......................................................................................................... 1 Getting Starte d ...........................[...]

  • Page 3

    Run ................................................................................................................................... 11 Display ed Items ................................................................................................................ 11 Sta y Tim e ..................................................................[...]

  • Page 4

    Customer s erv ice .............................................................................................................. 32 Contacting 3M I nstrumenta tion ......................................................................................... 32 Internatio nal cu sto mers .................................................................[...]

  • Page 5

    1 In troduction Up and Running overv i ew Introduct ion The QUEST empº 34/36 models ar e porta ble heat str ess m onitors that are designed to be rugged, ea sy - to use instrum ents to quickly and accurat ely as sess the po tential for individual heat str ess based on env ironment al condit ions. QUESTem pº Models The QU ESTempº 34 and QU ESTemp[...]

  • Page 6

    2 Gettin g Started Up and Running overv i ew Getti ng Started Up and Runni ng ov erview 2. Place th e QU ESTemp º 34 & 36 in the work area in a safe location approxim ately 3 .5 f eet of f the gro und. 3. Power On the QUES Temp º 34 & 36 and check t he battery . • If the battery volta ge displ ayed duri ng the power - on sequ ence is le[...]

  • Page 7

    Getting Started Keypad Operat i on 3 Keypad Oper at i on The unit o perates using a key pad w ith 4 keys. T he I/O Ente r key responds when the key is r elease d while a ll other keys res pond w hen the ke y is press ed. I/O Enter key The unit t urns on w ith a si ngle key press. The unit turns o ff by holding the k ey down w hile a countd own of 3[...]

  • Page 8

    Placement for Monitoring/ Testing Turning On/Off and Basic Operation 4 T urni ng On/O f f and Basic O perati on To quickly get you started with the Q UEST emp º 34 & 36 model , the f ollow ing sectio n explains h ow to tur n on th e instrume nt, ru n, and stop y our se ssion. 1. Press the I/O Enter key t o t urn on . Foll ow ing the model and [...]

  • Page 9

    Sensors Natural Wet Bulb Thermometer 5 Sensors Natural Wet Bulb Thermometer The natural wet bul b thermometer gives an indication of the effects of humidity on an individual. Relati ve humidity and wind speed are taken into account by measuring the amount of evaporati ve cooling t aking place at a thermometer c overed with a moi stened wick. Check [...]

  • Page 10

    Tri - sensor Cal culatio n and R emote Cab le Tri - sensor W eighted Average 6 Tri - sensor C al culation and Remote Cable The top s ensor bar (sensor 1) may be r emoved from the instr ument an d used through a r emote c able. S helter the instru ment and remote the sensor bar if t he measured env ironme nt is ex pecting h eavy r ain or if t empera[...]

  • Page 11

    Tri - sensor Cal culatio n and R emote Cab le Wet Bulb Globe Temperature 7 Measur e ments The QUESTem p ° 34 & 36 data log ging a rea he at stres s mon itor dir ectly s en s es t h e four para me te r s : am b ie nt or dry bu l b t emp er at ure ( DB ), na t u ra l w et b ul b t e mp er at ure (W B) , gl obe te mper at ur e (G), a nd re lativ [...]

  • Page 12

    Tri - sensor Cal culatio n and R emote Cab le Heat Index/Humidex 8 H eat Index/H umidex The H eat Ind ex is d et er mi n ed u si ng t he d ry b ulb t e m per at ur e a nd re la tiv e hu m id it y . Based upon ch arts avai lable f rom the U.S . Nationa l Weat her Servic e, Heat Index repre se nt s h ow an av e ra ge p erso n fe els r e la tiv e t o [...]

  • Page 13

    Operat ing QUES Tempº 34 & 36 View 9 Operati ng QUEST emp º 34 & 36 Use the U p Arrow and D o wn A rrow k e ys to move the marker in t he dis play in front of the desire d mode. Pressi ng the I/O Ent er k e y will sel ect the mode . V iew Displays the measu red data but doe s not log i t. If more th an one set of sens or s is plugged into[...]

  • Page 14

    Operating QUESTempº 34 & 36 Print 10 • Flow : On, Of f . • Index : n one, ACGI H, Navy, E PRI and se lec t either: WBGT i ( indoor), WBGT o ( outdoor ) for Index s ettin g. Index Setting s Explanation TLV and action limit These index settin gs only ap ply to the ACGIH I ndex. E PRI and Nav y w ill ignore this setting. Clothing Corr ection [...]

  • Page 15

    Display ed Items Run 11 Run The run mo de begins a ses sion in me mory and log s the d ata. 1. Begin a s ession by pressing t he R un/Stop key from the view mode ( or measur eme nt view ). An aster isk in th e lower right corner ind icates th e run mode.  To toggle through t he view s, press t he up or down arrow . F igure 1 -8 : Run mode indica[...]

  • Page 16

    Display ed Items Run 12 Screen 2: GLOBE Figure 1 - 10: G lobe scre en Screen 3: WB GTi ( Indoors ) WBGTo (O utdoors ) Figure 1 - 11 : WBG Ti & WBGTo screen Screen 4: RH (Relat ive Hum idity) H.I. or HU ( Heat Index or H umidex ) Figure 1 - 12 : RH and H.I/HU scre en Screen 5: A ir Flow (If tur ned O N vi a setup with Q UES T emp º 36 onl y ) F[...]

  • Page 17

    Data Logging St a y Time 13 S tay Time The screen(s) di spl ay ing stay time data a pp ear differ ent f or each of t he poss ible indices (av ailabl e with Q UES T emp º 36 model only). If ACGIH is selected, t he re commended working minutes pe r hour are show n for each of the w orklo ad categor ies Light (L ), M oderate (M ), H eavy (H ), and Ve[...]

  • Page 18

    Prin ting Serial 14 P rinting The recorded data can be sent to a computer thr o ugh the ser i al RS - 232 port or to a parallel print er. Ser ial tran smi ssion requir es 3M cable #54 - 7 15. Parall el transmissi on requir es 3M cable #56 - 875. W it h the ca ble plu gged in to the RS - 232 auxiliary port , select P rint from the menu and pr ess t [...]

  • Page 19

    Printi ng 15 Figur e 1 -20 : Sample printout (p age 2 ) Session: 3 Page 2 Sensor: 1 Degrees Fahrenhei t Stay Times: ACGIH, Acclimated, WBGTi, clo correction = 1.0 C TIME WBGTi WBGTo WET DRY GLOBE RH HI FLOW L M H VH ----- ----- ----- ----- ----- ----- --- --- ----- --- --- --- --- 11:08 68.7 67.9 59.4 82.4 90.7 13 0 0.5 60 60 60 60 11:09 69.0 68.1 [...]

  • Page 20

    Air F low f unction alit y 16 A ir F low functionalit y (Availabl e using 3M ’s Air Probe on QUES Tempº 3 6 mod el .) Air flow is mea sured i n meters per second ov er a ra nge of 0 t o 20m/s in 0.1m/s inc remen ts. T he sensor sh ould be p laced or held perpe ndic ular in th e air str eam. Unlike many anemo meters, t he omni - d irection al sen[...]

  • Page 21

    Operational Ch eck Operating sequence 17 O perating sequence 1. Turn F low O n in the s etup menu of the QU EST emp ° 36. 2. Plug the Air P robe int o the por t labeled Flow on the si de of t he QUES Temp ° 3 6. 3. Turn on the Air Probe ON and mak e sure th e green lamp i s lit. • In the V iew or Run mode s , air flow is disp layed o n the fift[...]

  • Page 22

    Power options 9- Volt Alkaline B att ery Replacement 18 P ower opt i ons There are 3 op tio ns for pow er in g t he Q U ES T e m p º 3 6 : a 9 - v olt al kal in e batte ry , a NiM H (Nick e l M eta l H y dri de ) r ech arge able 6 - cel l ba t t ery pac k, and an A C a dapt er. A d o or on the ba ck of the u nit al low s the us er acc ess to th e [...]

  • Page 23

    Power options NiMH Battery Pack 19 NiMH Battery Pack  WARNING: Recharg e batt eries only i n a non - hazardou s env iron ment. The NiM H rechargeabl e batter y pack is charged in the i ns tru ment us ing 3M ’s AC 120V AC to 9V DC ad apter (p art #015 - 91 0 ) or 220V AC t o 9V DC adapter (par t #015 - 680) . A dischar ged ba ttery pack requir [...]

  • Page 24

    Appendix A: Specifications 20 Appendix A: S peci ficati ons Measurements Globe temp erature , dry bulb t empera ture , w et bulb t emperat ure, % re lativ e humi dity , WBGTin, WBGTout, WBGT weig hted avera ge (if 3 sensor s ets), and H eat In dex / Humidex . Temperatur es given i n Cel sius or Fahr enheit. Data Logging Records an d prints all meas[...]

  • Page 25

    Appendix A: Speci fications 21 Remote Sensor Bars 2 x 15pin D -s ub jacks ar e loca ted on the side of the unit for p lugging in 1 or 2 additional sensor b ars by using rem ote cab les up to 20 0 feet (61m). The top sensor bar can a lso be remo te with a cable. Power Options 9V alkaline , 7.2V N iMH rechargeabl e pack (ch arged in the u nit), or AC[...]

  • Page 26

    Product markings and special condition s 22 P roduct mar kings and special condi tions KEMA 04AT EX1072 X <Ex> II 2 G E Ex ia IIC T3 Complian ce with Es sential H ealth and S afety Require ments has been as sured by complianc e with: EN 50014 : 1997 and EN 500 20 : 200 2 The year of manufact ure is d etermin ed by t he third charact er in th [...]

  • Page 27

    Appendix B: Heat Exposure Tables 23 Appendix B: Heat Exposure Tabl es ACG IH Screening Cr iteri a for Heat S tress Ex posure. WBGT values in ° C. NOTE: accordi ng to the ACGIH ’s guide lines, the temper ature v alues r epresent a work and re st proces s which is explained in the stan d ar ds. Please ref er to th e ACGIH TLVs and BEI s for sp ec [...]

  • Page 28

    Appendix B: Heat Exposure Tables 24 ACGIH Clothing C orrect ions The follow ing clothin g corr ections are in de grees Cel sius. W hen a clot hing corr ection i s entered in to the s etup port ion of the Q UEST emp ° 36 , the val ue is ad ded to th e W BG T only for looking up the stay times. T he W BG T v alue display ed by the unit does not ref [...]

  • Page 29

    Appendix B: Heat Exposure Tables 25 WBGT(F) I II III IV V VI 92.0 4:50 4:10 3:30 2:55 2:15 1:30 93.0 4:25 3:50 3:15 2:40 2:00 1:25 94.0 4:05 3:35 3:00 2:25 1:50 1:15 95.0 3:45 3:15 2:45 2:15 1:45 1:10 96.0 3:25 3:00 2:30 2:05 1:35 1:05 97.0 3:10 2:45 2:20 1:55 1:25 1:00 98.0 2:55 2:35 2:10 1:45 1:20 0:55 99.0 2:40 2:20 2:00 1:40 1:15 0:50 100.0 2:3[...]

  • Page 30

    Appendix B: Heat Exposure Tables 26 E lectri cal power research instit ute ( EPRI) The reco mmended w orking ho urs are s hown base d on a max imum of four ho urs. A ti me of 4:01 in dicates gr eater than 4 hour s . W BGT° C Light Moderate Heavy 28 4:01 4:01 3:00 29 4:01 4:00 2:00 30 4:01 3:00 1:30 31 4:01 2:00 1:15 32 4:00 1:30 1:00 33 3:30 1:15 [...]

  • Page 31

    Appendix C: Acces sories A ir Probe Accessori es 27 A ppendix C : Acce ssories Sens or arr ay wit h 2 in ch glo be 56- 795 Sens or arr ay wit h 6 in ch glo be 56 - 780 6 Foot s hiel ded re mo te se nsor cabl e 53 - 924 25 Foot shie lded rem ote s enso r cable 53 - 925 100 Fo ot shi elde d re mote sens or cab le 53 - 926 200 Fo ot shi elde d re mote[...]

  • Page 32

    Appendix D: Detec tion Mana gement Sof tware DM S DMS Qui ck ove rvie w 28 Appendix D: Detection Ma nagement S oftware DM S The QU ESTem p ° 34/36 has the flex ibilit y to comm unicate, downlo ad data, create rep orts, and s ave cus tomized setu ps using th e 3M TM D etection Managem ent Software DMS. DMS Quick overvi ew The f ocus of this section[...]

  • Page 33

    Appendix D: Detec tion Mana gement S oftware DM S Downloading y our sessions in DM S 29 3. Power on t he QUEST empº 3 6 b y pressing an d holding th e I/O Enter k e y. 4. Open DM S and c lick on button. 5. Selec t Heat Stress and then selec t the Model Type b y clickin g on QT ⁰ 34 or QT ⁰ 36. (See 1 and 2). ( You are no w ready to s etup or d[...]

  • Page 34

    Appendix D: Detec tion Mana gement S oftware DM S Viewing/Analy z ing and Quick Reporting in DMS 30 Viewing/ Analyzing and Quick R eporting in DMS In the Data F inder pa ge, your heat str ess data is stor ed by in strument family an d then by model. Ther e are tw o option s in th e data fi nder pag e which i nclude analy zing and printing a quick r[...]

  • Page 35

    Append ix D: Detec tion Mana gement S oftware DM S Reporting and Printing 31 Report ing and Printing If y ou are in the Data f inder page, yo u have the option to selec t button and this will give you a report ins tantaneo usly usi ng a s tandard tem plate of graph s and char ts (also ca lled panels .). • Viewing reports: if you are in the data l[...]

  • Page 36

    32 Appendix D Customer s er vice Contacti ng 3M Inst rumentation Should your 3M equip ment ne ed to be re turned f or repa ir or f or rec alibrati on, plea se contact the servic e depart ment at th e follow ing num ber or ac cess the on line for m via t he website. F or techn ical iss ues, please cont act Tec hnical Supp ort. Service Dep artment an[...]

  • Page 37

    Personal Safety Division 3M Detection Solutions 1060 Corporate Center Drive Oconomowoc, WI 53066 ISO 9001 Registered Company ISO 17025 Accredited Calibration Lab Customer Service: 262-567-9157 T oll Free: 800-245-0779 www .3m.com/detection 3M is a t radem ark of 3 M C ompany used u nder lice nse in C anada . Plea se re cycle. Pr inted in U S A . ©[...]