3M 78-0013-4441-1-D manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of 3M 78-0013-4441-1-D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of 3M 78-0013-4441-1-D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of 3M 78-0013-4441-1-D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of 3M 78-0013-4441-1-D should contain:
- informations concerning technical data of 3M 78-0013-4441-1-D
- name of the manufacturer and a year of construction of the 3M 78-0013-4441-1-D item
- rules of operation, control and maintenance of the 3M 78-0013-4441-1-D item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of 3M 78-0013-4441-1-D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of 3M 78-0013-4441-1-D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the 3M service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of 3M 78-0013-4441-1-D.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the 3M 78-0013-4441-1-D item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    3M ™ One Pass Mini FiberPathw ay Installation Instructions December 2012 78-0013-4441-1-D 3 The Network of Networks.[...]

  • Page 2

    2 78-0013-4441-1-D 3M ™ One Pass Mini F iber Pathway Contents 1.0 System Overvie w ............................................................................................................................ 3 2.0 Components and Accessories ......................................................................................................... 3[...]

  • Page 3

    78-0013-4441-1-D 3 3M ™ One Pass Mini F iber Pathway 1.0 System Over view The One Pass Mini Fiber P athway is designed for use in FTTP (Fiber-to-the-Premise) netw orks within brownfield or greenfield Multi Dwelling Units (MDUs). The One Pass Mini Fiber Pathway is a surf ace-mount, adhesive-back ed drop cable and pathway solution designed for indo[...]

  • Page 4

    4 78-0013-4441-1-D 3M ™ One Pass Mini F iber Pathway 3.2 ILU installation tools are wear items, and should be replaced on a bi-annual basis, or approximately ev ery 500 installed units. Sooner as required. 3.3 Additional Recommended T ools (Not Included) A B D E F C G H a) Drill b) Stapler c) Splicer’ s Knife d) Fiber Snips e) ScotchBlue ™ Pa[...]

  • Page 5

    78-0013-4441-1-D 5 3M ™ One Pass Mini F iber Pathway 4.3 Hang weight from strip. Release tab T ab hole 4.4 Remov e successful test strips by pulling on release tab T est W eight Hang Time Result > 60 seconds P ASS – Install < 60 second F AIL – Do not install The path the duct will follow MUST be clean and dry . • Clean all surfaces al[...]

  • Page 6

    6 78-0013-4441-1-D 3M ™ One Pass Mini F iber Pathway • Do not remov e duct from box. Route end through handle as shown and pay of f duct. 6.0 Exposing Fiber For T ermination Expose 2-4' (610-1220 mm) of fiber fr om the end of the duct before terminating using the following method: 6.1 Snip the flange on either side of the duct, being caref[...]

  • Page 7

    78-0013-4441-1-D 7 3M ™ One Pass Mini F iber Pathway 7.3 After exposing appropriate length of f iber for termination, attach duct by aligning the end of the duct with the recessed area in the base. Remov e the liner and press firmly into place. DO NOT ROUTE the 900 µm fiber into the outlet box until installation of the duct and termination of th[...]

  • Page 8

    8 78-0013-4441-1-D 3M ™ One Pass Mini F iber Pathway 10.0 Planar Cor ner Installation 10.1 Peel adhesi ve liners and attach support in duct path. Marking grooves Mark flange at groove Leave 12" (300 mm) of liner intact 10.2 T rim the duct flange using the 3M ™ One Pass Mini Duct Flange Remov al T ool. Example direction of travel Align mar[...]

  • Page 9

    78-0013-4441-1-D 9 3M ™ One Pass Mini F iber Pathway 11.0 Mechanical Anchor Installation 11.1 Remov e liner, align groo ve with duct and press firmly into place. The anchor may be secured with a T -25 staple if desired. T -25 Staple here (optional) • Use the adhesi ve-backed anchor where ver additional adhesion is required, such as: high stress[...]

  • Page 10

    10 78-0013-4441-1-D 3M ™ One Pass Mini F iber Pathway 14.0 Connector T ermination and Final Steps 14.1 T erminate the f iber using a 3M ™ No Polish Connector or 3M ™ Crimplok+ Connector . Anchor furcation tubing Feed through from living unit 3M ™ One Pass Point-of-Entry Box (Hallway Side) 14.2 In buildings where the One P ass Fiber Pathway [...]

  • Page 11

    78-0013-4441-1-D 11 3M ™ One Pass Mini F iber Pathway 15.0 Fiber Repair 15.1 Ensure that the root cause for service interruption is damaged 900 µm. 15.2 W orking away from the W all Outlet, mak e small window cuts using the W indow Cut T ool at e very other corner or turn. Note: Additional window cuts at other corners may be made if needed. Wind[...]

  • Page 12

    3M and ScotchBlue are trademarks of 3M Company . Important Notice All statements, technical information, and recommendations related to 3M’ s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intend[...]