Go to page of
Similar user manuals
-
Sphygmomanometer
A&D Medical UA-631
72 pages -
Sphygmomanometer
A&D Medical TM-2430
36 pages -
Sphygmomanometer
A&D Medical UA-767
13 pages -
Sphygmomanometer
A&D Medical UA-789
27 pages -
Sphygmomanometer
A&D Medical UA-853
26 pages -
Sphygmomanometer
A&D Medical UB-512
23 pages -
Sphygmomanometer
A&D Medical UA-704
64 pages -
Sphygmomanometer
A&D Medical UA-767PBT
14 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of A&D Medical UA-705, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of A&D Medical UA-705 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of A&D Medical UA-705. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of A&D Medical UA-705 should contain:
- informations concerning technical data of A&D Medical UA-705
- name of the manufacturer and a year of construction of the A&D Medical UA-705 item
- rules of operation, control and maintenance of the A&D Medical UA-705 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of A&D Medical UA-705 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of A&D Medical UA-705, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the A&D Medical service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of A&D Medical UA-705.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the A&D Medical UA-705 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
A DV ANCED M ANUAL I NFLA TE Blood Pr essur e Monitor T rilingual Instruction Guide – MODEL UA-705 English • Français • Español UA705 6/3/05 12:46 PM Page 1[...]
-
Page 2
Please read this important information before using your monitor . ☞ Please remember that only a medical practitioner is qualified to inter- pret your blood pressur e measurements. Use of this device should not replace regular medical examinations. ☞ Have your physician review your pr ocedure for using this device. He or she will want to verify[...]
-
Page 3
Fast. Easy . Accurate. Congratulations on pur chasing a state-of-the-art LifeSour ce ® blood pr essur e monitor—one of the most technologically advanced monitors available today . Designed for ease of use and accuracy , this monitor will facilitate your daily blood pr es- sur e r egimen. Physicians agr ee that daily self-monitoring of blood pr e[...]
-
Page 4
WHA T DISPLA Y SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . E-2 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . E-3 HOW UA-705 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 BEFORE YOU ST ART . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 SELECTING THE CORRECT CUFF SIZE . . . . . . . . . . . . . [...]
-
Page 5
In Canada - Auto Control Medical (T oll-Free): 1-800-461-0991 E-2 WHA T DISPLA Y SYMBOLS MEAN ? Display Symbol Recommended Action Measurement is in progr ess, remain as still as possible. T ake measurement again and con- sult with your physician. Replace all batteries with new ones when the symbol blinks. Alkaline batteries recommended. T r y the m[...]
-
Page 6
LifeSource Health Line (T oll-Free): 1-888-726-9966 E-3 MONITOR COMPONENTS ? ? ARM CUFF PROPER FIT RANGE INDEX MARK AIR HOSE DISPLA Y ST ART BUTTON AIR SOCKET AIR CONNECTOR PLUG EXHAUST RUBBER BULB BA TTERY COVER AA BA TTERY BA TTERY COMP ARTMENT UA705 6/3/05 12:47 PM Page 7[...]
-
Page 7
In Canada - Auto Control Medical (T oll-Free): 1-800-461-0991 E-4 Y ou must install 1 type AA (1.5 volt) batter y and attach the cuff to the monitor before using it (alkaline batteries recommended). T o install battery (or replace it if the "Low Battery" symbol appears on display), proceed as follows: 1. Remove battery cover by gently pus[...]
-
Page 8
LifeSource Health Line (T oll-Free): 1-888-726-9966 E-5 USE SMALL CUFF USE LARGE CUFF PROPER FIT RANGE INDEX I N D E X Ea SELECTING THE CORRECT CUFF SIZE ARM SIZE RECOMMENDED CUFF SIZE REPLACEMENT CUFF MODEL# 9.4” - 14.2” (24-36cm) 14.2” - 17.7” (36-45cm) Medium Cuff Large Cuff UA-280 UA-281 ! Using the correct cuf f size is important for a[...]
-
Page 9
In Canada - Auto Control Medical (T oll-Free): 1-800-461-0991 E-6 Tips for Blood Pressure Monitoring: ☞ Relax for about 5 minutes before measurement. ☞ Do not smoke or ingest caffeine at least 30 minutes prior to measurement. ☞ Remove constricting clothing and place cuff on bar e arm. ☞ Unless your physician recommends otherwise, use left a[...]
-
Page 10
5. Press the ST AR T button. Y our average blood pressur e reading will appear with the number of measurements stored in memory (i.e. A25 = total of 25 measurements stored in memory) and a flashing symbol, indicating that monitor is ready for measurement. NOTE: If th e symbol is displayed, the cuff has some air trapped in it. Press the exhaust valv[...]
-
Page 11
In Canada - Auto Control Medical (T oll-Free): 1-800-461-0991 E-8 T AKING YOUR BLOOD PRESSURE 8. When the correct pressurization has been r eached, the automatic exhaust mechanism will gradually reduce the pressur e in the cuff. Sit quietly during measurement. The ❤ symbol will blink with your pulse beat. NOTE: Exhaust rate cannot be adjusted dur[...]
-
Page 12
LifeSource Health Line (T oll-Free): 1-888-726-9966 E-9 The UA-705 Blood Pressure Monitor pr ovides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. The Irr egular Heartbeat symbol will appear in the display window in the event an Irregular Heartbeat has occurred during measur ement. An irregular heartbeat is def[...]
-
Page 13
In Canada - Auto Control Medical (T oll-Free): 1-800-461-0991 E-1 0 ABOUT A VERAGE READING ABOUT PRESSURE RA TING INDICA TOR™ The Pressure Rating Indicator ™ is a feature which pr o- vides a snapshot of your blood pressure classification based on your measurements. This will let you quickly know what your blood pressure r eadings mean. Each seg[...]
-
Page 14
LifeSource Health Line (T oll-Free): 1-888-726-9966 E-11 ABOUT MEMOR Y The UA-705 automatically stores up to 30 blood pressur e and pulse measure- ments in its memory . Measurements stored in memory are assigned an index number in the order of the newest to the oldest. The oldest r eading displays as "n01". T o retrieve readings, follow t[...]
-
Page 15
In Canada - Auto Control Medical (T oll-Free): 1-800-461-0991 E-1 2 What Is Blood Pressure? Blood pressure is the for ce exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pr essure occurs when the heart expands. Blood pressure is measur ed in millimeters of mercury (mmHg). What Affects [...]
-
Page 16
LifeSource Health Line (T oll-Free): 1-888-726-9966 E-13 ABOUT BLOOD PRESSURE Assessing High Blood Pressure for Adults The following standards for assessing high blood pr essure (without regar d to age or gender) have been established as a guideline. Please note that other risk factors (e.g. diabetes, obesity , smoking, etc.) need to be taken into [...]
-
Page 17
In Canada - Auto Control Medical (T oll-Free): 1-800-461-0991 E-1 4 ABOUT BLOOD PRESSURE What Is Hypertension? Hypertension (high blood pressure) is the diagnosis given when r eadings consistently rise above normal. It is well known that hypertension can lead to stroke, heart attack or other illness if left untr eated. Referred to as a “ silent k[...]
-
Page 18
LifeSource Health Line (T oll-Free): 1-888-726-9966 E-15 ABOUT BLOOD PRESSURE Answers to Why Y our Readings Are Different Between Home and at the Doctor’ s Office Why are my readings differ ent between home and at a doctor’ s office? Y our blood pressure readings taken in a doctor ’ s of fice or hospital setting may be elevated as a result of[...]
-
Page 19
In Canada - Auto Control Medical (T oll-Free): 1-800-461-0991 E-1 6 ABOUT BLOOD PRESSURE Establishing Baseline Measurements The most important method to get an accurate blood pressure measur ement is consistency . T o get the most benefit out of your monitor , it is important to establish a “ baseline measurement. ” This helps build a foundatio[...]
-
Page 20
LifeSource Health Line (T oll-Free): 1-888-726-9966 E-17 TROUBLESHOOTING Problem Nothing appears in the display , after pressing the ST AR T button. The cuff does not deflate properly The unit does not measure. Readings are too high or too low . The value is differ- ent from that meas- ured at a clinic or doctor ’ s office. Probable cause Battery[...]
-
Page 21
In Canada - Auto Control Medical (T oll-Free): 1-800-461-0991 SPECIFICA TIONS Model . . . . . . . . . . . . . . . . . . . . . UA-705 T ype . . . . . . . . . . . . . . . . . . . . . . Oscillometric Display . . . . . . . . . . . . . . . . . . . Digital character height; Pressure (15.0 mm)/pulse (10.0 mm) display simultaneously Memory . . . . . . . . [...]
-
Page 22
E-19 CONT ACT INFORMA TION Our products ar e designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and treatment options. Our full pr oduct line includes: Digital Blood Pressure Monitors Manual Blood Pressure Kits Blood Pressure Cuffs Stethoscopes Personal Health Scales Neb[...]
-
Page 23
A division of A&D Engineering, Inc. 1756 Automation Parkway San Jose, CA 95131 www .LifeSourceOnline.com P r essu r e Rating Indicator is a trademark and LifeSou r ce is a r egiste r ed trademark of A&D Medical. Pr essure Rating Indicator is patent pending. ©2007 A&D Medical. All rights r ese r ved. Specifications subject to change wit[...]