A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of A&D UA-704, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of A&D UA-704 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of A&D UA-704. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of A&D UA-704 should contain:
- informations concerning technical data of A&D UA-704
- name of the manufacturer and a year of construction of the A&D UA-704 item
- rules of operation, control and maintenance of the A&D UA-704 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of A&D UA-704 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of A&D UA-704, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the A&D service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of A&D UA-704.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the A&D UA-704 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    T rilingual Instruction Guide – MODEL UA-704 Mini Manual Inflate Blood Pressure Monitor LA TEX FREE Please read this impor tant information before using your monitor . ☞ Please remember that only a medical practitioner is qualified to interpret your blood pr essure measurements. Use of this device should not replace r egular medical examination[...]

  • Page 2

    E- 1 WHA T DISPLA Y SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . E-2 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . E-3 HOW UA-704 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 BEFORE YOU ST ART . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-4 SELECTING THE CORRECT CUFF . . . . . . . . . . . . . [...]

  • Page 3

    m m Hg m mH g(/m in) UA-704 DIGITAL BLOOD PRESSURE MONIT OR MEASU RING PRESSE EXHAUST INFLATE IR R G U L AR H EART B EA T BATTERY LOW SYS. D IA.(PU L.) E- 3 E- 2 MONITOR COMPONENTS ? Display Symbol Recommended Action Remain still and refrain from talking; measur ement in progr ess. Press exhaust button to release air . Inflate cuff 30 to 40 mmHg ab[...]

  • Page 4

    E- 5 E-4 Using the correct cuf f size is important for an accurate reading. A cuf f that is too large will pr oduce a reading that is lower than the correct blood pr essure; a cuff that is too small yields a measurement that is higher . W ith your arm hanging at the side of your body , measure the cir cumference of your upper arm at the midpoint be[...]

  • Page 5

    E- 7 E- 6 ☞ IMPORT ANT: Measure pressure at the same time each day . 4. Press the ST AR T button 5. W atch for all display symbols to appear briefly , followed by a flashing “0”, indicating that monitor is ready for measurement. 6. If the mark is displayed, the cuff has some air trapped in it. Press the exhaust valve button until the mark is [...]

  • Page 6

    E- 9 E- 8 T AKING YOUR BLOOD PRESSURE 12. Remove cuff and make a note of your blood pr essure and pulse rate on the chart (see page E-13), indicating date and time of measurement. Additional logbook charts can be downloaded and printed for fr ee at www .lifesourceonline.com or www .autocontrol.com. W e advise that you recor d the date and time afte[...]

  • Page 7

    E- 1 1 E- 1 0 Assessing High Blood Pressure The following standards for assessing high blood pr essure (without regar d to age) have been established as a guideline. BP Classification Systolic (mmHg) Diastolic (mmHg) Normal <120 and <80 Prehyper tension 120-139 or 80-89 Stage 1 Hypertension 140-159 or 90-99 Stage 2 Hypertension ≥ 160 or ≥[...]

  • Page 8

    E- 1 2 ABOUT BLOOD PRESSURE ❤ Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pressur e readings taken in a doctor’ s office or hospital setting might be elevated as a result of appr ehension and anxiety . This response is commonly called “white coat hypertension.” One way to determine whether this[...]

  • Page 9

    TROUBLESHOOTING ✓ SPECIFICA TIONS ✓ Problem Display is blank, even when the power is turned on. The device will not measure. Readings are too high or too low . Other Probable cause Battery is drained. Battery terminals are not in the correct position. The cuff is not fastened properly . Y ou moved your arm or body during the measurement. The cu[...]

  • Page 10

    CONT ACT INFORMA TION A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www .LifeSourceOnline.com LifeSour ce is a trademark of A&D Medical. ©2003 A&D Medical. All rights reserved. Specifications subject to change without notice. I-MAN:704 Printed in China 02/04 IMPORT ANT! If Y ou Need Assistance with the Se[...]