The rules should oblige the seller to give the purchaser an operating instrucion of AB Soft TDW-33, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of AB Soft TDW-33 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of AB Soft TDW-33. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of AB Soft TDW-33 should contain:
- informations concerning technical data of AB Soft TDW-33
- name of the manufacturer and a year of construction of the AB Soft TDW-33 item
- rules of operation, control and maintenance of the AB Soft TDW-33 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of AB Soft TDW-33 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of AB Soft TDW-33, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the AB Soft service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of AB Soft TDW-33.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the AB Soft TDW-33 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
TDW-33 DIN-r ail T ele V .90 modem www .w estermo .com REV .A 6619-2202 2008.05 Mälar tryck AB, Eskilstuna, Sweden © W estermo T eleindustri AB User Guide 6619-2202[...]
-
Page 2
2 6619-2202 Legal information The contents of this document are provided “as is”. Except as required by applicable law , no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability a[...]
-
Page 3
3 6619-2202 Safety Befor e installation: This modem is for restricted access area use only . Read this manual completely and gather all information on the unit. Make sure that you understand it fully . Check that your application does not exceed the?[...]
-
Page 4
4 6619-2202 Agency appr o vals and standards compliance T ype Appr o val / Compliance EMC EN 61000-6-2, Immunity industrial environm EN 55024, Immunity IT equipment EN 61000-6-3, Emission residential envir onments FCC part 15 Class B EN 50121-4, Railwa y signalling and te[...]
-
Page 5
5 6619-2202 If trouble is experienced with this equipment TD W -33, for repair or warranty information, please contact W estermo Data Communication,Inc. 11200 W estheimer ,Suit 900. Houston,TX,,77042. Phone number : 713-240-0367. If the equipment is causing?[...]
-
Page 6
6 6619-2201 Declaration of Conformity W este rmo Teleindu stri AB Declara tion o f conf ormit y Org.nr/ Postadress/Po stal addres s Tel. Tele fax Pos tgi ro Bankgiro Corp. ide ntity number Register ed office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 The manuf[...]
-
Page 7
7 6619-2201 T ype tests and envir onmental conditions Electromagnetic Compatibility Phenomena T est Description T est levels ESD EN 61000-4-2 Enclosure contact ± 6 kV Enclosure air ± 8 kV RF field AM modulated IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 kHz), 80 – 2000 MHz[...]
-
Page 8
8 6619-2202 Description The TD W -33 is designed to function reliably within industrial environments and in areas of high level interference. The modem has an RS-232 interface suppor ting terminal data rates up to 115 kbit/s. The TD W -33 is a V .90 m[...]
-
Page 9
9 6619-2202 Interface specifications ** T o minim ise the risk of int erf er ence, a shie lded cable is r ecom mend ed when the cabl e is locat ed insi de 3 m boun dary to the rai ls and con nect ed to this port. The cable shield should be pro perl y conn ecte[...]
-
Page 10
P osition RJ-11C Direction* Description Product marking PSTN a Not Connected b Not Connected c In/Out PSTN T ransmit/ Receive d In/Out PSTN T ransmit/ Receive e Not Connected f Not Connected P osition Scre w terminal* Direction* Description – Not Connected Data Carrier Direct (DCD) No. 2 Out Rec[...]
-
Page 11
11 6619-2202 LED Indicators LED Status Description TD T ransmit data OFF No data ON / FLASH The modem receiving data on the DTE interface RD Receive data OFF No data ON / FLASH The modem transmitting data on the DTE interface R TS Request to send OFF R TS signal i[...]
-
Page 12
12 6619-2202 Cooling This unit uses convection cooling. T o a void obstructing the air - flow around the unit, use the following spacing rules. Minimum spacing 25 mm (1.0 inch) above /below and 10 mm (0.4 inches) left /right the unit. Spacing is re[...]
-
Page 13
13 6619-2202 Windo ws configuration tool TD-T ool The TD-T ool is a PC – application program with a graphical interface for easy configuration of the complex functions found on the encolsed CD or at the W estermo website. Please ref er to TD-T ool for[...]
-
Page 14
14 6619-2202 PSTN Network Application examples … TD W -33 connected to TD W -33 with DTR signal call DTR DSR DCD Rela y External application 10 kohm Ma y be required in harsh environments. Configure the units A T&F Set the unit to factory default A T&W Store default[...]
-
Page 15
15 6619-2202 … Fr equently used settings for PLC-systems Most PLC-systems and other industrial applications where modems are used requir e the same changes to the standard settings. The most commonly encountered problems concern speed, parity and contro[...]
-
Page 16
16 6619-2202 … TD W -33 – Secure Call-back The TD W -33 is connected to a PLC which one want to restrict access to. The TD W -33 can support access control through the Secure Callback function. In this example pass- wor d and callback to a?[...]
-
Page 17
17 6619-2202 Configure the TD-36 Set up the connection A T&F Set the unit to factory default A T+IPR=9600 DTE baudrate 9600 A T+ICF=3,4 Character framing 8 data, 1 stop, parity none A TS0=1 Auto answer after first ring A T&W Store default settings The dialling?[...]
-
Page 18
18 6619-2202 … TD W -33 – Silent answering on predefined number The TD W -33 is connected to a power meter which is remotely monitored. The TD W -33 shares the PSTN line with normal telephones which is preferr ed not to give a ring signal w[...]
-
Page 19
[...]
-
Page 20
REV .A 6619-2202 2008.05 Mälar tryck AB, Eskilstuna, Sweden W estermo T eleindustri AB • SE-640 40 Stora Sundby , Sweden Phone +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo .se W estermo W eb site: www .w estermo .com W estermo T eleindu[...]