ACDelco PN 09301 A manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ACDelco PN 09301 A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ACDelco PN 09301 A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ACDelco PN 09301 A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ACDelco PN 09301 A should contain:
- informations concerning technical data of ACDelco PN 09301 A
- name of the manufacturer and a year of construction of the ACDelco PN 09301 A item
- rules of operation, control and maintenance of the ACDelco PN 09301 A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ACDelco PN 09301 A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ACDelco PN 09301 A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ACDelco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ACDelco PN 09301 A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ACDelco PN 09301 A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Manual Page 1 Pressure Washers and Accessories KING BRUTE ( PN 09301 A ) Operators Manual and Parts Lists Delco Pressure Washers LIT-KING-DEL Re v1 1 1- 07[...]

  • Page 2

    L I M I T E D W A R R A N T Y At DELCO ® CLEANING SYSTEMS, we distribute top quality industrial / commercial / personal pressure washers that are designed for heavy-duty use, maximum reliability, durability, and long life. Our pressure washers are built for all duty applications and steady use due to higher quality levels. The manufacturer of this[...]

  • Page 3

    L I M I T E D W A R R A N T Y ( c o n t ) Parts / Co m ponents Warranty Period and Deta il s High Pressure Pumps Five (5 ) year limited manufactuer warranty on pu m p workmanship and defects in material. Lifetime on forged brass manifold. Warranty does not apply to failures on ot her pump parts due to: • Freight da m age • Freeze damage • Dam[...]

  • Page 4

    Manual Page 4 IMPORTANT SAFETY PRECAUTIONS IMPORTANT: Please read the following instructions before installing and operating this equipment. DANGER THIS EQUIPMENT CAN BE HAZA RDOUS TO OPERATOR SAFETY AND ONLY AUTHORIZED PERSONNEL WHO HAVE READ AND UNDE RSTAND T HE INSTALLATION AND OPERATION MANUAL SHOULD BE PERMITTED TO OPERATE T HIS EQUIPMENT. DO [...]

  • Page 5

    Manual Page 5 14. Always cool down coil. DO NOT’S DO NOT - UNDER ANY CIRCUMSTANCES - POINT THE HIGH PRESSURE NOZZLE AT YOURSELF, OTHER PEOPLE, OR ANIMALS! 1. DO NOT use an undersized discharge nozzle. 2. DO NOT disconnect the pressure hoses or wand while the equipment is HOT, PRESSURIZED or RUNNING. 3. DO NOT operate this equipment without suffic[...]

  • Page 6

    Manual Page 6 INSTALLATION 1. LOCATION Avoid operating units in small areas or near ex haust fans. A dequate oxygen is needed for combustion or dangerous carbon monoxide will result. Stationary units should be installed in accordance with local plumbing and heating codes. 2. FUEL SUPPLY Oil Fired Units: Fill fuel tank with clean kerosene, No. 1 hom[...]

  • Page 7

    Manual Page 7 OPERATING THE MACHINE PRE-OPERATING INSTRUCTIONS 1. Connect the swivel end of the discharge hose to the cleaning gun. 2. Attach the hose to the machine outlet. 3. Check the fuel level in the fuel tank. Add fuel if r equired. It is best to keep fuel tank full during nonworking conditions. 4. Attach an ordinary garden hose to the float [...]

  • Page 8

    Manual Page 8 SHUT DOWN INSTRUCTIONS 1. If the burner is on turn control switch to position 1(pump). 2. Run water through the pump until cool water flows from the cleaning gun. Failure to do this cou ld result in increased coil scaling. 3. Turn the control switch to off. 4. Turn off the water supply. 5. If the machine will be exposed to freezing te[...]

  • Page 9

    Manual Page 9 MAINTENANCE OF COMPONENTS PUMPS 1. Refer to pump section in this manual for your model of equipment. 2. Change pump oil after the first 25 hours of use. Subsequent changes should be every 250 hours or 3 months, whichever comes first. A. Disconnect power supply. B. Remove drain plug on pump and drain oil. C. If the oil has water in it,[...]

  • Page 10

    Manual Page 10 6. FUEL PUMP: To bleed air out of fuel pump, open air bleed valve on side of fuel pump. Turn machine and burner ON. When fuel looks clear (NOT FOAMING), close air bleeding valve. Air is out of fuel lines and fuel pump. A. To check fuel pressure, plumb a 200 PSI gauge into the port marked gauge. DO NOT USE BLEED VALVE PORT TO CHECK FU[...]

  • Page 11

    Manual Page 11 DE-SOOTING COIL Poor grades of fuel oil or inadequate combustion air will cau se heavy soot build up on the outside surface of the heating coil. This will insulate the coil and rest rict air flow through the coil, further aggravating the soot build up. To clean off soot, add Red Devil Soot Remover, using manufactures mixing instructi[...]

  • Page 12

    Manual Page 12 DIAGNOSIS AND MAINTENANCE PROBLEM PROBABLE CAUSE SOLUTION Low Pressure Worn nozzle Replace nozzle of proper size. Belt slippage. Tighten or replace; use correct belt. Air leak in inlet plumbing. Use PTFE liquid or tape. Pressure gauge inoperative or not registering accurately. Check pressure with new gauge and replace as needed. Reli[...]

  • Page 13

    Manual Page 13 Notes:[...]

  • Page 14

    Repair Kits Pos Code Description Qty . 44 67 40 69 41 42 70 2 1 3 4 5 4 3 1 2 6 7 8 9 13 12 11 10 14 15 16 17 18 19 20 21 22 23 24 25 27 33 28 27 34 35 36 37 38 28 32 31 30 27 28 71 72 73 74 57 3 (6) 4 (6) 6 (3) 16 30 (3) 42 10 7 (3) 32 (3) 33 (3) 25 (3) 24 (3) 23 (3) 22 (3) 21 (3) Valv e Kit # PP A1554 Qty 6 of each part included per kit Piston Ki[...]

  • Page 15

    PP A0015 Unloader Code Description Qty . Special Parts / Kits Repair Kits Pos Code Description Qty . Pos Code Description Qty . 15 19 14 17 12 6 11 13 16 18 20 21 22 23 24 1 2 3 4 5 7 8 10 9 Repair Kits O-Rings 12 (2) 14 (1) 15 (1) 18 (1) 20 (1) 23 (1) 14 11 12 (2) 13 Unloader 15 16 18 19 1 PP A1560 Cap 1 2 PP A1561 Screw 1 3 PP A1562 Nut 1 4 PP A1[...]

  • Page 16

    Manual Page 1 6 BURNER (Beckett 12V) COMPONENT LOCATOR & PARTS LIST Ref.No. Part No. Qty. Description 1 29601A 1 Air Shutter 2 29602A 1 Air Band 3 29603A 1 Escutcheo n Plate 4 29604A 1 Gasket, Squar e Plate 5 29605A 1 Air Tube Flange Assembly 6 193871 1 Flange Gasket 7 45027A 1 Motor 8 962139 1 Mounting Screws 1/4" - 20NC x 5/8 9 29606A 1 [...]

  • Page 17

    Manual Page 1 7 ELECTRICAL SCHEMATIC (12VDC)[...]

  • Page 18

    Manual Page 1 8 GUNVALVE AND HOSE ASSEMBLY COMPONENT LOCATOR[...]

  • Page 19

    Manual Page 1 9 GUNVALVE AND HOSE ASSEMBLY COMPONENT LOCATOR PARTS LIST Ref. No. Qty . Part No. Description 1 1 QC-251-22 O-Ring / O-Anillo 2 1 QC-250-51 Female Socket, ¼ / Ancla Hembra, ¼ 3 1 GE-600-36 Extension T ube, 3 ft / Tubo de Extensión, 3 ft 4 1 GC-590- 40 Spray Gun / Pistola Aerografica 5 2 QC-381-22 O-Ring / O-Anillo 6 1 192278 Quick [...]

  • Page 20

    Manual Page 20 GC 590-40 GUNVALVE COMPONENT LOCATOR[...]

  • Page 21

    Manual Page 2 1 GC 590-40 GUNVALVE COMPONENT LOCATOR PARTS LIST Ref. No. Qty. Part No. Description 1 1 GC-765-14 Housing (Right) / Carcasa (Derecho) 2 1 8001660 Housing (Left) / Carcasa (Izquierdo) 3 1 GC-765-75 Trigger / Gatillo 4 1 GC-764-44 Pin / Pasador 5 1 8002258 Valve Body / Cuerpo de la Valvula 6* 1 GC-765-22 T rigger Cam / Leva de Gatillo [...]

  • Page 22

    1111 E. Lake Francis Dr. • Siloam Springs, AR 72761 • 1-800-B UY-DELCO[...]