A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ACTiSYS ACT-IR100SD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ACTiSYS ACT-IR100SD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ACTiSYS ACT-IR100SD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ACTiSYS ACT-IR100SD should contain:
- informations concerning technical data of ACTiSYS ACT-IR100SD
- name of the manufacturer and a year of construction of the ACTiSYS ACT-IR100SD item
- rules of operation, control and maintenance of the ACTiSYS ACT-IR100SD item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ACTiSYS ACT-IR100SD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ACTiSYS ACT-IR100SD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ACTiSYS service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ACTiSYS ACT-IR100SD.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ACTiSYS ACT-IR100SD item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    The W ireless Connectivity Expert 4851 1 W arm Springs Blvd., Suite 206, Fr emont CA 94539 Te l : +1-510-490-8024 F a x : +1-510-623-7268 We b s i t e : http://www .actisys.com/ E-mail: irda-info@actisys.com ACT -IR100SD OBEX Server IrReady Intelligent Adapter User ’ s Manual October 30, 2006 V er . 1.0 © Copyright 2000-2006 ACTiSYS Corporation [...]

  • Page 2

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 7. ACT -IR100SD DONGLE DIMENSIONS .............................................................. 17 V ersion 1.0 T ABLE OF CONTENTS REVISION H ISTOR Y ............................................................................................... 3 PRECAUTIONS ............[...]

  • Page 3

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual REVISION HIST OR Y Revision History Revision Date Comment 1.0 10/30/2006 Draft Preliminary Design S pecification.  Copyright 2000-2006 ACT iSYS Corp. Page 3 of 17 Oct 30, 2006 V ersion 1.0[...]

  • Page 4

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual PRECAUTIONS T o ensure trouble-free operation, please observe the following precautions: Optical communications are easily affected by exte rnal light sources, weak batteries, transfer distance, transfer angle, etc. Any of these conditions may cause a data transfer failure[...]

  • Page 5

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 1. FEA TURES  A complete IrDA Protocol stack in a dongle.  Supports both IrDA Primary and Secondary mode, changeable via PC utility .  No driver program is needed.  Supports mandatory IrDA layer: IrPHY , IrLAP , IrLMP and IAS.  Supports upper layers T inyTP [...]

  • Page 6

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 2. OVERVIEW The ACT -IR100SD is a high-integration IrDA Intelligent dongle. It provides a seria l interface to a host device that intends to have Infrared communication capability . The host device can be any equipment or device that needs to communicate with IrDA enabled [...]

  • Page 7

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 3. ARCHITECTURE OF ACT -IR100SD The mandatory IrDA protocol layers, IrLAP and IrLMP (including IAS) are handled by ACT -I R100SD, In addition, T i nyTP , IrCOMM, IrLPT and OBEX transport are also included. The incoming/outgoing IrDA user data p ayload are buffered and then[...]

  • Page 8

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual  Copyright 2000-2006 ACT iSYS Corp. Page 8 of 17 Oct 30, 2006 4. HOST INTERF ACE The host interface of ACT -IR100SD is a full-duplex asynchronous RS232 DB9M connector . The following table is the signals of D B9M connector . It can be treated as DTE. The data bytes are [...]

  • Page 9

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 4.1 Host Interface Signals ACT -IR100SD host interface consists of three output signals and five input signals. All these signals are low active. That is, they are at 0V when active and at VCC level when inactive. When an inverting RS232 level converter is used, the corres[...]

  • Page 10

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual  Copyright 2000-2006 ACT iSYS Corp. Page 10 of 17 Oct 30, 2006 V ersion 1.0 5. OPERA TING IN ACT -IR100SD 5.1 How T o Connect IR100SD With Host Device: IR100SD uses a standard RS232 DTE port to connect with the host. If the host device is a Modem like device and has a R[...]

  • Page 11

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.1 The first page is to set the host baud rate and the hardware flow control. Please Note: Ignore CTS: If host device has no hardware flow control signals, only Tx, Rx and GND, then you have to set this bit to 1. IR100SD will pass the coming dat a to host and doesn’t [...]

  • Page 12

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.2 The second page is to set time interval of discovery , the slot number of discovery and the mode of IR100SD. 1) IR100SD supports both Primary and Secondary . It allows customer to change it. 2) Discovery time should be 3 seconds in general. If you want the discovery [...]

  • Page 13

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.2.3 The third page is to set the IrDA protocols when IR100SD is in Primary .  Copyright 2000-2006 ACT iSYS Corp. Page 13 of 17 Oct 30, 2006 V ersion 1.0[...]

  • Page 14

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual 5.3 OBEX PUT/GET Description The OBEX specification consist s of two major part s: a protocol and an application framework. This is also illustrated graphically below . The "application framework" is represented in ellipses inside the "wide word of applicati[...]

  • Page 15

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual The following figure shows how cellphone or PDA delivers an object (maybe a phone book record, a picture or a formatted data) to user’s host. W hen IR100SD-OBEX-Server receives OBEX PUT command, it will act like a PUT ser ver and reply proper response. Then it will trim [...]

  • Page 16

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual Frame length means total frame size, including byte 0,1, 2, and 3. For example, if dat a frame is 300 bytes, length should be 304. 6. THE DEF AUL T SETTING OF ACT -IR100SD The default setting of ACT -IR100SD is configured as the following: Parameters Setting Host baud rate[...]

  • Page 17

    The W ireless Connectivity Expert ACT -IR100SD OBEX Server User ’ s Manual  Copyright 2000-2006 ACT iSYS Corp. Page 17 of 17 Oct 30, 2006 7. ACT -IR100SD DONGLE DIMENSIONS 8. CHARACTERISTICS AND SPECIFICA TION Parameter Min. T ypical Max. Unit s DC supply v oltage 6.0 7.5 12 V Supply v oltage, VSS 0 V Operating temperature range, TA 0 60 ℃ D[...]