Go to page of
Similar user manuals
-
Network Card
ACTiSYS ACT-IR220LN
10 pages 0.33 mb -
Network Card
ACTiSYS ACT-IR100MP
18 pages 0.61 mb -
Network Card
ACTiSYS IR100SLM
20 pages 0.34 mb -
Network Card
ACTiSYS ACT-IR8250SW
21 pages 0.79 mb -
Network Card
ACTiSYS IR2000UL
20 pages 0.7 mb -
Network Card
ACTiSYS ACT-IR210L
14 pages 0.78 mb -
Network Card
ACTiSYS ACT-IR320L
6 pages 0.35 mb -
Network Card
ACTiSYS IrDA PC Adapter ACT-IR220L+/220L/200L
37 pages 4.29 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of ACTiSYS ACT IR100SLM, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ACTiSYS ACT IR100SLM one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of ACTiSYS ACT IR100SLM. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of ACTiSYS ACT IR100SLM should contain:
- informations concerning technical data of ACTiSYS ACT IR100SLM
- name of the manufacturer and a year of construction of the ACTiSYS ACT IR100SLM item
- rules of operation, control and maintenance of the ACTiSYS ACT IR100SLM item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ACTiSYS ACT IR100SLM alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ACTiSYS ACT IR100SLM, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ACTiSYS service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ACTiSYS ACT IR100SLM.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the ACTiSYS ACT IR100SLM item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
The W ir eless Connectivi ty Expert 4851 1 W arm Springs Blvd., Su ite 206, Frem ont CA 9453 9 T el : (510) 490-802 4 Fax: (510) 62 3-7268 We b s i t e : http://www .actisys.com/ E-mail: irda- info@act isys.co m ACT-IR100SL and ACT-IR100SL-M User’s Manual (IrDA Intelligent RS232 Adapters) © Copyright 2000- 2002 ACT iSYS Corporation, All Rights R[...]
-
Page 2
- 1 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 FCC & VCCI Compliance Statement This device c omplies with p art 15 of the FCC Rules. O peration is subj ect to the follo wing t wo conditio ns: (1)T his device m a y not caus e harmf ul inter ferenc e, and (2) this de vice m ust ac cept an y interf erence received, incl[...]
-
Page 3
- 2 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 T ABLE OF CONTENTS PRECAU TIONS........................................................................................................... 3 1. Featarus.................................................................................................................. 4 2. Ove[...]
-
Page 4
- 3 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 PRECA UTIONS T o ensure trouble-free operation, please observe the following precautions: Optical communications are easily af fected by external light sources, weak batteries, transfer distance, transfer angle, etc. Any of these conditions may cause a data transfer failure,[...]
-
Page 5
- 4 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 1. Features Support IrDA standard including: - Ir LAP - IrLM P - T iny TP - I r C O MM - IrOBEX transport Other standards: - IrLP T IrDA baud rate supported: - 9.6kbps - 19.2kbps - 38.4kbps - 57.6kbps - 1 15.2kbps IrDA Primary/Secondary Mode supported: - IR100SL : Secondary [...]
-
Page 6
- 5 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 Host interface baud rate supported: - 1.2kbps - 2.4kbps - 4.8kbps - 9.6kbps - 19.2kbps - 38.4kbps - 57.6kbps - 1 15.2kbps[...]
-
Page 7
- 6 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 75L V47 37 IR8200IC IR220V ACF TXDO /RXDI / MODE / RESET /RXD0 /TXD 0 Optic al T ransceiver /TX D1 /RXD1 /RT S1 /CTS1 /DSR1 /DTR1 /CD1 /RI1 /RTS0 /DTR0 /RXDO /TXD I EEPRO M RTS CTS DSR DTR CD RI TXD RXD SEL0 SEL1 SEL2 : : /RT S1 /CTS1 /DSR1 /DTR1 /CD1 /RI1 /TXD /RXD 2. Overv[...]
-
Page 8
- 7 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 3. A pplicat ions 3.1 Embedded IrDA protocol stack The mandatory IrDA protocol layers, Ir LAP (comply with TEST frame capability requir ement) and IrLMP (including IAS) are handled by ACT-IR100S-L/LM, In addition, Ti nyTP , IrCOMM, IrLPT , IrOBEX transport are all included. [...]
-
Page 9
- 8 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 I r L M P a n d I A S IrLAP IrLPT or IrCOM M 3- wire r aw IrCOMM 9-wire TinyTP OBEX T rans p ort Tiny TP HOST IrPHY encoder-decoder ( ACT-IR220V A CF ) UART1 UART0 Buffers IrDA T ransceive r RS232 converter ( 75L V737A ) ACT- IR100S-L ACT-IR8200IC -L[...]
-
Page 10
- 9 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4. Operation Setting, EEPROM, and other optional hardware 4.1 Serial EEPROM There are some special functions i f t he external serial EEPROM installed. The optional serial EEPROM allow users to set ”Host Speed” and “Hardware Flow Control and Connection Control”. The [...]
-
Page 11
- 10 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.2 Baud Rate Setting Jumpers SEL0-2 and serial EPROM setting s are used to set the hos t interface RXD and TXD data rate. Note that this is independent of the IrDA connection data rat e. Data format is always 8 data bits, no parity , and 1 stop bit. Note that this is compa[...]
-
Page 12
- 11 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.3 Ignore DSR SEL3 open (SEL3=1) m eans i g n o r e t he ph y sical DSR inpu t, p r e t end t h a t DSR is on. This logical DSR is always used for connection control. The physical DTR is used f or connection indicat ion. SEL3 has no ef fect on DTR. W h e n SEL3 close (SEL3[...]
-
Page 13
- 12 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.5 EEPROM Function Disable Jumper SEL7 is use to enable or disable EEPROM f unct ion. If this function disable, IR100S-L/ L M will use SEL0~SEL4 setting only . If this function enable, IR100S-L/LM will use EEPROM setting and jumpers SEL0~SEL4 a re ignored. Note: 1. SEL5 ~ [...]
-
Page 14
- 13 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.6 On Line Change Host Speed and Hard w are Flow Control/Connection Control The ACT-IR100S-L/LM allowed user to change Host Speed or Hardware Flow Control/Connection Control in run tim e. IRSET can change setting and w rite new value into the EEPROM via IR. COMSET can chan[...]
-
Page 15
- 14 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 4.7 RS-232C DTE DB-9P Connector Pin No. Name Descriptions I/O 1 CD Data Carr ier Det ect I 2 RXD Receiver Data I 3 TXD Transmitter Data O 4 DTR Data T erm inal Ready O 5 GND Signal Ground GND 6 DSR Data Set Ready I 7 R TS Request to Send O 8 CTS Clear to Send I 9 RI Ring In[...]
-
Page 16
- 15 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 5. How to Connect IR100S-L/LM with host Device IR100S-L/LM uses a standard RS232 D TE port to connect with the host. If the host dev ice is a Modem like device and has a RS232 DCE port, then use a "straight cable". That is, connect the signals with the same name f[...]
-
Page 17
- 16 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 IR100S-L TXD RXD RTS CTS DSR DTR CD RI GND DTE RXD TXD CTS RTS DT R DS R CD RI GND If the host device is a PC like device and has a RS232 DTE port too, then you need to use a "Null Modem" connection betw een the t wo. That is, in/out signal pairs need to be crosse[...]
-
Page 18
- 17 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 OTHER ACT iSYS IrDA PRODUCTS I (A CT-1 ): IrDA Primary Statio n Pro toco l Stack !" IrLAP, IrLMP, IAS and o ptional T iny TP, IrCOM M, IrM C, IrTr an-P, etc.. !" For PDA, d igita l cam era, handhel d data t erm inal, pal mtop c omputer, sm ar t phone. !" Very[...]
-
Page 19
- 18 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 THE FOLLOWING W ARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHT S THAT VARY FROM STATE TO STATE. LIMITED W ARRA NT Y ACTiSYS Corporation warrants to the first consumer purchaser , for a period of 1 y ear from the date of purchase, that this wirele[...]
-
Page 20
- 19 - ACT-IR100SL and IR100SL-M User’s Manual V ersion 1.20 May 27, 2002 Copyright 199 5-2001 ACT iSYS Corp. 4851 1 W arm Springs Blvd, Suite 206, Fr em ont, CA 94539, USA T el:+1-510-490-8024 Fax:+1-510- 623-7268 Internet: irda-info@act isys.com W eb Site: http://www .actisys.com Corporation[...]