Acu-Rite 02005TBDI manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Acu-Rite 02005TBDI, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Acu-Rite 02005TBDI one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Acu-Rite 02005TBDI. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Acu-Rite 02005TBDI should contain:
- informations concerning technical data of Acu-Rite 02005TBDI
- name of the manufacturer and a year of construction of the Acu-Rite 02005TBDI item
- rules of operation, control and maintenance of the Acu-Rite 02005TBDI item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Acu-Rite 02005TBDI alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Acu-Rite 02005TBDI, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Acu-Rite service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Acu-Rite 02005TBDI.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Acu-Rite 02005TBDI item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Instruction Manual SAVE THIS MANU AL FOR FUTURE REFERENCE. Questions? Contact Cust omer Suppor t at ( 8 77) 22 1 - 1 25 2 or visit www . AcuRite .com. Weat her St ation model 02005TBDI CONTENTS Unpac king Instr uctions ........... 2 P ackage Contents .................. 2 Product R egistration ............... 2 Features & Benets: Sensor .....[...]

  • Page 2

    2 Congratulations on y our new A cuRite product. T o ensure t he best possible product perf ormance, please read t his manual in its entirety and retain it for future ref erence. Unpac king Ins tructions Remo v e the protective lm t hat is applied to the LCD screen prior to using this product. Locate the t ab and peel of f to remov e. Pac kage C[...]

  • Page 3

    3 24 25 26 27 28 29 30 31 32 33 1 2 3 4 5 6 7 13 14 15 8 16 17 18 Features & Benets Display Unit Fr ont Display Unit Bac k 34 35 36 12 19 20 21 23 9 10 11 9 22[...]

  • Page 4

    4 DISPL AY UNIT FRONT 1 . Day of t he Week 2. Current Outdoor Temperature Arrow icon indicates the direction t he temperature is trending. 3. Outdoor Sensor Signal Strengt h 4. High/Low Outdoor Humidity Records Highest and low est humidity records based on record vie wing mode (#9). 5. High/Low Outdoor T emperature Records Highest and low est tempe[...]

  • Page 5

    5 SETUP Set the A-B-C Switc h The A -B-C switc h is located inside the batt er y compar tment. It can be set to A , B or C. Ho w ev er , you must select the same letter c hoices for bot h the sensor and the displa y unit in order for the units to sync hronize. Install or Replace Batteries AcuRite recommends high quality alkaline or lithium batter i[...]

  • Page 6

    6 Display Unit Se tup Set the A-B-C Switc h Locat e the A -B-C switch inside the batt er y compar tment. Set the A -B-C switch to A , B or C. Y ou must select the same le tter c hoices for bot h the displa y unit and the sensor in order for t he units to sync hronize. Install or Replace Batteries 1 . Remo v e the batter y compar tment cover . 2. In[...]

  • Page 7

    7 A B C D E F G Setup: Geog raphic Region Select your geogr aphic region according to the map (pictured r ight) by pr essing the “geo” button, located on t he bac k of the unit in the batt er y compar tment. The letters for eac h corresponding GEO region are sho wn on the display screen. Geographic region must be set in order for Precision Fore[...]

  • Page 8

    8 Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding envir onmental conditions. Proper placement of bot h the display unit and outdoor sensor are cr itical to the accuracy and perf ormance of t his product. Display Unit Placement Place display unit in a dr y area free of dir t and dust. Display stands upright f or tabletop [...]

  • Page 9

    9 Using t he Weather S tation Precision Weat her Forecas ting AcuRite’s Precision Forecasting pr ovides y our personal forecast of morning, noon & night (4 hour , 4 to 8 hour and 8 to 1 2 hour) weat her conditions. The patent-pending tec hnology combines regional weather patter ns with dat a measured b y a sensor in your y ard. It gener ates [...]

  • Page 10

    10 Troubleshooting No outdoor sensor reception no bars If the wireless signal indicator shows no bars: • Relocate t he display unit and/or the outdoor sensor . The units must be within 330 f t (1 00 m) of each ot her . • Make sure both units are placed at least 3 fee t (.9 m) away from electronics that may inter f ere with t he wireless communi[...]

  • Page 11

    11 Troubleshooting Inaccurate for ecast • W eather Forecast icons predict conditions for the future, not current conditions. • Forecast will be blank for rst 4 hours af ter batter y installation. • Make sure y our GEO region is correct. If y ou live close to a region border , tr y t esting both regions to see whic h generates the most appr[...]

  • Page 12

    12 Replace Intelli-T ime ® Cloc k Batter y Intelli-T ime tec hnology is pow ered b y a pre-installed coin-cell batter y t hat stores the time and dat e settings. The batter y has a shelf lif e of sev eral y ears. T o replace t he Intelli-T ime batter y: 1 . Locate t he coin cell batter y inside t he batter y compar tment of display unit. Unscrew a[...]

  • Page 13

    13 Specications TEMPERA TURE RANGE Outdoor: -40 º F to 1 58 º F; -40 º C to 70 º C Indoor: 32 º F to 1 22 º F; 0 º C to 50 º C HUMIDITY RANGE Outdoor: 1% to 99% RH Indoor: 1% to 99% RH WIRELESS RANGE 330 f t / 1 00 m depending on home constr uction materials OPERA TING FREQUENCY 433 MHz POWER Dis pla y: 3 x AA alkaline batteries Sensor: [...]

  • Page 14

    14 At AcuRite, we proudly uphold our commitment to quality tec hnology . Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. W e recommend t hat you visit us at www .AcuRite.com for [...]

  • Page 15

    15[...]

  • Page 16

    16 ©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy- rights are the property of their respective owners. AcuRite uses patented technology . Visit www .AcuRite.com/patents for details. Printed in China 02005TBDI INST 100 7 1 4 It’ s mor[...]