ADTRAN FT1 manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of ADTRAN FT1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ADTRAN FT1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of ADTRAN FT1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of ADTRAN FT1 should contain:
- informations concerning technical data of ADTRAN FT1
- name of the manufacturer and a year of construction of the ADTRAN FT1 item
- rules of operation, control and maintenance of the ADTRAN FT1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ADTRAN FT1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ADTRAN FT1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ADTRAN service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ADTRAN FT1.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the ADTRAN FT1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Section 61245211L1-5, Issue 1 61245211L1-5A 1 PRACTICES SINGLE-WIDE FT1 REPEA TER INST ALLA TION/MAINTENANCE Contents 1. General ................................................................................ 1 2. Installation ........................................................................... 3 3. Installation of FT1 Repeaters in ADTRAN A[...]

  • Page 2

    2 Section 61245211L1-5, Issue 1 61245211L1-5A The ADTRAN Single-Wide FT1 Repeater provides three faceplate LEDs which indicate signal quality, error conditions, and loopback status. See Table A for a description of the LED indicators. Operating power is derived from an ADTRAN FT1 DP, independent of line impedance or wire gauge. The repeater uses so[...]

  • Page 3

    Section 61245211L1-5, Issue 1 61245211L1-5A 3 2. INSTALLATION CAUTION This equipment contains static-sensitive components. Be sure to follow proper electrostatic discharge procedures before handling or installing the equipment. The Single-Wide FT1 Repeater circuit pack is shipped in a separate carton and must be installed in an environmental appara[...]

  • Page 4

    4 Section 61245211L1-5, Issue 1 61245211L1-5A 4. MAINTENANCE The ADTRAN Single-Wide FT1 Repeater requires no routine maintenance. In case of equipment malfunction, perform an in-band loopback from the central office (CO), as described in Appendix A of this practice. If a malfunction is confirmed, replace the Single-Wide FT1 Repeater. FT1 Repeater L[...]

  • Page 5

    Section 61245211L1-5, Issue 1 61245211L1-5A 5 Table C. Loop Insertion Loss Data Frequency Maximum Loss (Hz) (dB) 3000 ...................... 12.0 10,000 ...................... 15.0 50,000 ...................... 25.5 100,000 ...................... 30.0 150,000 ...................... 32.75 200,000 ...................... 35.25 5. CSA DEPLOYMENT GUIDEL[...]

  • Page 6

    6 Section 61245211L1-5, Issue 1 61245211L1-5A Loop Interface Modulation Type .................................. 2B1Q Mode ..................................................... Full Duplex, Echo Cancelling Number of Pairs ................................... One Bit Rate ................................................. 784 kbps per pair Baud Rate ..[...]

  • Page 7

    A-1 Section 61245211L1-5, Issue 1 61245211L1-5A APPENDIX A FT1 LOOPBACKS 1. GENERAL This Appendix is an overall reference to the loopback capabilities of the ADTRAN Fractional T1 system. Included in the Appendix is a description of the FT1 loopbacks and the methods for activating the FT1 loopbacks. 2. FT1 LOOPBACKS Figure A-1 shows the application [...]

  • Page 8

    A-2 Section 61245211L1-5, Issue 1 61245211L1-5A There is one loopback available to the FT1 Repeater. The FT1 Repeater Network loopback is a digital loopback toward the CO as shown in Figure A-4. The loopback is initiated by the DDS latching loopback code for NEI Position 1 (N1000001). The NEI Position 1 latching loopback is detected in the primary [...]

  • Page 9

    A-3 Section 61245211L1-5, Issue 1 61245211L1-5A 3. LOOPBACK ACTIVATION AND DEACTIVATION This section describes loopback activation and deactivation methods for the ADTRAN Fractional T1 system. Loopback activation and deactivation is controlled with the push-button located on the front panel, through craft interface, or latching loopback codes. A pu[...]

  • Page 10

    A-4 Section 61245211L1-5, Issue 1 61245211L1-5A 4. LOOP-UP STATE In the loop-up state, the active FT1 loopback will provide a continuous loop for the FT1 bandwidth. The data flow is continuously monitored for the loop deactivation commands to deactivate the loopbacks. Also, a loopback timeout is checked. If the loopback timeout is enabled, any loop[...]