Go to page of
Similar user manuals
-
Switch
ADTRAN Hub
20 pages 0.76 mb -
Network Card
ADTRAN IQ SERIES
2 pages 0.04 mb -
Network Card
ADTRAN 3010
2 pages 0.28 mb -
Network Router
ADTRAN NetVanta 3200
27 pages 11.45 mb -
Battery Charger
ADTRAN NIU3
6 pages 0.15 mb -
Switch
ADTRAN NetVanta 1224R
13 pages 4.79 mb -
Network Router
ADTRAN 1203860G1
90 pages 2.4 mb -
Network Card
ADTRAN MX2800
1 pages 0.45 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of ADTRAN NT1 T400, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of ADTRAN NT1 T400 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of ADTRAN NT1 T400. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of ADTRAN NT1 T400 should contain:
- informations concerning technical data of ADTRAN NT1 T400
- name of the manufacturer and a year of construction of the ADTRAN NT1 T400 item
- rules of operation, control and maintenance of the ADTRAN NT1 T400 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of ADTRAN NT1 T400 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of ADTRAN NT1 T400, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the ADTRAN service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of ADTRAN NT1 T400.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the ADTRAN NT1 T400 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
NT1 Type 400 NT1 T ype 400 Standalone 1212 016L 1 NT1 T yp e 400 Circuit Pack 1212010 USER MANUAL 61212016L1 -1B January 1999[...]
-
Page 2
This dev ice complies with Part 15 o f the FCC rules . Operation is subject to the following two co nditions: (1) This device may not cause harmful in- terference, and (2) this device must accept any interf erence received, in- cluding interference that may cause unde sired operation. Changes or modifications to this unit not express ly approved by[...]
-
Page 3
FCC regulations require that the following information be provided in this manual: 1. This equipm ent complies with Part 6 8 of the F CC rules. On the bottom of th e equipment ho using is a la bel that shows the FCC registration number an d Ringer Equivalence Number (R EN) for this equipment. If requested, provide this information to the telephone [...]
-
Page 4
ADTRAN YEAR 2000 (Y2K) READINE SS DIS CLOSURE ADTRAN has established a Y ear 2000 program to ensur e that our pr od- ucts and operations will corr ectly function in the new millennium. ADT- RAN warrants that all pr oducts meet Y ear 2000 specifications r egar dless or model or r evision. Information about ADTRAN’s Y ear 2000 compli- ance p r ogr [...]
-
Page 5
CUSTOMER INSTRUC TIONS 1. The mounting of the registered unit in th e final assembly must be made so that the registered unit is isolated from exposure to any hazardou s voltages wit hin the assembly. Adequa te separa- tion and restraint of cables an d cords must be provided. 2. The circu itry fr om the reg istered unit to th e telephon e line must[...]
-
Page 6
CANADIAN EMIS SIONS REQUIREMENTS This digital apparatus does not ex ceed the Class B limits for radio noise emis- sions from digital apparatus as s et out in the interference-causing equip ment stan- dard entitled "Di git al Apparatus," ICES-003 of the Departm ent of Communicat ions. Cet appareil numerique respecte les limites de bruits r[...]
-
Page 7
CANADIA N EQUIP MENT L IMITATI ONS Notice: The Canadian Industry and Science Canada label identifies certif ied equip- ment. This certification means that the equipm ent meets certain telecom munications network protecti v e, operational, and safety requirements. The Depa rtment does not guarantee the equipment will operate to the user’ s satisfa[...]
-
Page 8
61212016L1-1 NT1 T400 User Manual ix T able of Contents 1.0 GENERA L ................. ................... .................... ................... .... 1 1.01 Unit Overvi ew ................. .................... ................... ................. 1 1.02 Basic Rate Des cripti on ... ....... ...... ....... ...... ....... ...... ....... ...... ..[...]
-
Page 9
Table of Contents x NT1 T400 User Manual 61212016L1-1 FIGURES Figure 1. NT1 Type 400 Standalon e Rear Panel ........... ................. 2 Figure 2. NT1 Type 400 Switch Option Locations .......... ................. 3 Figure A -1.NT1 T400 Cir cuit Pack Conn ector Pin Assignment s .. .. 10 Figure B -1.Short Pass ive Bus Co nfiguration ...... .......[...]
-
Page 10
61212016L1-1 NT1 T400 Us er Manual 1 1.0 GENERA L 1.01 Unit Overvi ew The ADTRAN NT1 Type 400 provides a basic rate interface be- tween the customer’s ISDN Terminal Equipment ( TE) and the ISDN Network. Two interfaces are provided for this purpose: con- nection to the ISDN n etwork is m ade by the “U ” interface and connection to the customer[...]
-
Page 11
. 2 NT1 T400 User Manual 61212016L1-1 1.02 Basi c Rate Description ISDN Basic Rate Service consi sts of two “B” cha nnels at 64 kbps and a single “D” cha nnel at 16 kbps. Basic Rate Ser vice (2B+D Ser- vice) provides a total of 144 kbps to the customer for the transpo rt of voice, circuit switched data, and packet switched data. Each “B?[...]
-
Page 12
61212016L1-1 NT1 T400 Us er Manual 3 2.0 INSTA LLAT ION After unpacking the unit, im mediately inspect it f or possible sh ip- ping damage. If da mage is d iscovered, file a claim imme diately with the carrier, then contact ADTRAN Customer and Product Service (CAPS) Department at the number listed in the back of the manu al. 2.01 S etting the Optio[...]
-
Page 13
. 4 NT1 T400 User Manual 61212016L1-1 2.02 Powering Up th e NT1 Typ e 400 Standalone To power-up the NT1 Type 400 Sta ndalone for the first time, per- form the follow ing procedures in o rder: 1. Plug the power cord into a grounded, 120 VAC, 60 Hz recepta- cle. 2. Verify that the ERROR indicators are illuminated. After about 15 secon ds, the READY [...]
-
Page 14
61212016L1-1 NT1 T400 Us er Manual 5 READY indicators and the TE’s ability to place and receive calls, depending on the specific TE in use. If the REA DY indicators fail to illuminate or if you are unable to place or receive calls, see Sec- tion 3.0 Troubleshooting on pag e 5 . 3.0 TROUBLESHOOTING If you enco un ter problems du ring in stallati o[...]
-
Page 15
. 6 NT1 T400 User Manual 61212016L1-1 4.0 MA INTEN ANCE The ADTRAN NT1 Type 400 requires no routine maintenance to operate. In ca se of equipment ma lfunction, refer to S ections 5.0 and 6. 0 below, and / or remove the unit and replace it with another unit optioned in an identical ma nner. 5.0 REMOTE TESTING Network test features incl ude a loopba [...]
-
Page 16
61212016L1-1 NT1 T400 Us er Manual 7 7.0 SPE CIFICATI ONS LOOP INTERF ACE: Line: 2-Wire (TIP and RING ) Oper ating Mode : Full -duplex Data Rate: 160 kbps total; 144 kbps available to custom er Signal Format: 2B1Q Output Amplitude: 2.5 V , zero-to-peak Tx Source Impedance: As per ANSI T1.601 Rx Source Impe dance: As per ANSI T1.601 Receiver Se nsit[...]
-
Page 17
. 8 NT1 T400 User Manual 61212016L1-1[...]
-
Page 18
61212016L1-1 NT1 T400 Us er Manual 9 APPENDI X A NT1 TYPE 400 CIRCUIT PACK RACK INSTAL LATIO N The ADT RAN NT1 Type 400 Circu it Pack, Pa rt No. 121201 0, can be purchase d as a sepa rate u nit for i nstall ation in a Type 400 NCTE ra ck. This config uration pro- vides a ce ntral locat ion for the NT1 in a cus tomer's wiring c loset, and fac i[...]
-
Page 19
. 10 NT1 T400 User Manual 61212016L1-1 Figure A- 1: NT1 T400 Circu it Pack Connector P in Assignmen ts S/T T ransmit (Customers 1 & 2 in parallel) U T ransmit/Receive S/T T ransmit (Customers 1 & 2 in parallel 55 53 51 49 47 45 43 41 39 37 35 33 31 29 1 3 5 7 9 11 27 25 23 21 19 17 15 13 56 54 52 50 48 46 44 42 40 38 36 34 32 30 2 4 6 8 10 [...]
-
Page 20
. 61212016L1-1 NT1 T400 Us er Manual 11 APPEND IX B S/T BUS C ON FIGURAT IONS SHORT PASSIVE BUS The short passive bus configuration allows the conn ection of up to e ight TEs at any point on the bus. The bus l ength i s limited to 600 feet, as illus trated i n Figure B-1 . To sel ect this bus c onfigurat ion, set switc h 1-2 to the Shor t pos ition[...]
-
Page 21
. 12 NT1 T400 User Manual 61212016L1-1[...]
-
Page 22
T echnical Support and W arranty Information Presales Inquir ies and Appli cations Support Please contact your local distributor , ADTRAN Applications Engineer- ing, or ADTRAN Sa les: Applications Engineering (800) 615-1 176 Sale s ( 8 00) 827 -08 07 Post-Sale Support Please contact your local distri butor first. If your local distributor cannot he[...]