Advantech EKI-12741F manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Advantech EKI-12741F, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Advantech EKI-12741F one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Advantech EKI-12741F. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Advantech EKI-12741F should contain:
- informations concerning technical data of Advantech EKI-12741F
- name of the manufacturer and a year of construction of the Advantech EKI-12741F item
- rules of operation, control and maintenance of the Advantech EKI-12741F item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Advantech EKI-12741F alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Advantech EKI-12741F, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Advantech service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Advantech EKI-12741F.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Advantech EKI-12741F item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EKI-2741F 10/100/1000Bas e-T to SFP (mini-GBIC) Type Fiber Optic Media Converter EKI-2741SX 10/100/1000Bas e-T to 1000Base-SX SC Type Fiber Optic Media Converter EKI-2741LX 10/100/1000Bas e-T to 1000Base-LX SC Type Fiber Optic Media Converter User Manual[...]

  • Page 2

    EKI-2741F-SX-LX User Manual ii Copyright The documentation and the software i ncluded wi th this product are copyrighted 2007 by Advantech Co., Ltd. All rights ar e reserved. Advantech Co., Ltd. reserves the right to mak e improvements in the pro ducts describe d in this ma nual at any time without noti ce. No part of this manual may be reproduced,[...]

  • Page 3

    iii Product Warranty (2 years) Advantech warrants to you, the or igina l purchaser, that each of its products will be fre e from defects in materials and workmanshi p for two years from the date of purchase. This warranty does not apply to any prod ucts which have been repai red or altered by persons other than repair personnel autho rized by Adv a[...]

  • Page 4

    EKI-2741F-SX-LX User Manual iv Declaration of Conformity CE This product has passed the CE test for envir onmental spe cifications. Test conditions for passing included the equipment being operated within an indust rial enclosure. In order to protect the product from being damaged by ESD (Elect rostati c Dischar ge ) and EMI leakage, we strongly re[...]

  • Page 5

    v Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC out let before clea ning. Use a damp cloth. Do not use liquid or spray detergents for clean ing. 4. For plug-in equipment, the power outlet sock et must be located near the equipment and mu[...]

  • Page 6

    EKI-2741F-SX-LX User Manual vi Safety Precaution - Static Electricity Follow these simple precautions to protect your self from harm and the produ cts from damage. 1. To avoid electrical shock, always di sconnec t the power from your PC chassis before you work on it. Don't touch any components on the CPU card or other cards whil e the PC is on[...]

  • Page 7

    vii Contents Contents Chapter 1 Overview ........................................... 2 1.1 Introduction ......................................................... 2 1.1.1 Fast Fiber Converters Module ................... 2 1.1.2 Dual Power Input ....................................... 2 1.1.3 Flexible Mounting ...................................... 2[...]

  • Page 8

    EKI-2741F-SX-LX User Manual viii[...]

  • Page 9

    1 Chapter1 Overview Sections include: z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER[...]

  • Page 10

    EKI-2741F-SX-LX User Manual 2 Chapter 1 Overview 1.1 Introduction The EKI-2741 is designed to convert Gi gabit Ethernet networks to Gigabit fiber networks by transparently converting Ethern e t signals to optic sig nals. The advantages of fiber optics are wide bandwidth, EMI immunity and long-distan ce transmission capability. Therefore, EKI-2741 i[...]

  • Page 11

    3 Chapter1 1.2 Features • Provides 1 x SFP (mini-GBIC) type connector (EKI-2741F) • Provides 1 x 1000Base-SX or 1000Base-LX SC type connector (E KI-2741SX/LX) • Provides 1 x 10/100/1000Mbps Ethernet ports with RJ-45 connector • Supports full/half duplex flow control • Supports MDI/MDI-X auto-crossover • Supports surge (EFT) protection 3[...]

  • Page 12

    EKI-2741F-SX-LX User Manual 4 1.3 Specification Communications Standard IEEE 802.3, 802.3ab, 802.3u, 802.3x, 802.3z LAN 10/100/1000Base-TX, 1000Base -SX, 1000Base-LX Transmission Distance Multi-Mode Fiber: 550m (EKI-2741SX) Single-Mode Fiber: 10km (EKI-2741LX ) or SFP (mini-GBIC) Fiber: Up to 110km (EKI-2741F) Ethernet: Up to 100 meters (STP or UTP[...]

  • Page 13

    5 Chapter1 Environment Operating Temperature -10 ~ 60 ℃ (14~140 ℉ ) Wide temp. model: -40 ~ 75 ℃ (-40 ~ 167℉) Storage Temperature -40 ~ 85 ℃ (-40 ~ 185 ℉ ) Operating Humidity 5 ~ 95% (non-conde nsing) Storage Humidity 0 ~ 95% (non-condensi ng) Certifications Safety UL, 60950-1, CAN/CSA-C22.2 No.60950 EMC U.S.A.: FCC Part 15 CISPR 22 EU:[...]

  • Page 14

    EKI-2741F-SX-LX User Manual 6 1.4 Packing List • 1 x EKI-2741F or EKI-2741SX or EKI -2741LX Industrial Ethernet Switch • 1 x eAutomation Industrial Communication CD-ROM with software, and User m anual • 2 x Wall Mounting Bracket and Screws • 1 x DIN-rail Mounting Bracket and Screws • 1 x EKI-2741F/SX/LX Startup Manual • 1 x DC Jack Cabl[...]

  • Page 15

    7 Chapter2 Installation Sections include: z LED Indicators z Dimensions z Mounting z Network Connection z Power Connection CHAPTER[...]

  • Page 16

    EKI-2741F-SX-LX User Manual 8 Chapter 2 Installation In this chapter, you will be given an over view of the EKI-2741F/SX/LX hardware installation procedures. 2.1 LED Indicators There are few LEDs display the power stat us and network statu s located on the front panel of EKI-2741F/SX/LX, each of them has its o wn specific meanin g as the table belo[...]

  • Page 17

    9 Chapter2 2.2 DIP-Switch The DIP-Switch is used to config ure operation mode for LFP ( Link Fault Pass- Through ) and operation mode for UT P/Fiber port. The default value of DIP-switch i s OFF . Table 2.2: EKI-2741series DIP-Swit ch Definition S/W No Status Description ON Enables Port/Power Alarm 1 OFF Disable Port/Power Alarm ON Enables LFP 2 OF[...]

  • Page 18

    EKI-2741F-SX-LX User Manual 10 2.3 Dimensions (units: mm) Figure 2.1: Front View of EKI-2741 series[...]

  • Page 19

    11 Ch apter2 Figure 2.2: Side View of EKI-2741 series[...]

  • Page 20

    EKI-2741F-SX-LX User Manual 12 Figure 2.3: Rear View of EKI-2741 series[...]

  • Page 21

    13 Ch apter2 The terminal block of power & relay is located o n the top side. Please refer to page 16 for pin assignment. Figure 2.4: Top View of EKI-2741 series[...]

  • Page 22

    EKI-2741F-SX-LX User Manual 14 2.4 Mounting The EKI-2741F/SX/LX support two mounting methods: DIN-rail & Wall. 2.4.1 Wall mounting EKI-2741F/SX/LX can be wall-mounted by using the included mou nting kit. Then, hang on the EKI-2741F/SX/LX to the nails on the wall. First, use the screws inclu ded in the package to co mbine the EKI-2741F/SX/ LX an[...]

  • Page 23

    15 Ch apter2 2.4.2 DIN-rail Mounting You can also mount EKI-2741F/SX/LX on a standard DIN-rail by below steps. The DIN-rail kit is screwed on the industrial sw itch when out of factory. If the DIN-rail kit is not screwed on the industrial switch, please screw the DIN-rail kit on the switch first. First, hang the EKI-2741F/SX/LX to the DIN-rail with[...]

  • Page 24

    EKI-2741F-SX-LX User Manual 16 Then, let the device down straight to slide over the rail smoothly. See Figure 2.7 Figure 2.7: Installation to DIN-rail Step 2[...]

  • Page 25

    17 Ch apter2 2.5 Network Connection • Twisted-pair segment can use unshielded tw isted pair (UTP) or shi elded twisted pair (STP) cabling. The cable between the lin k pa rtner (switch, hub, workstation, etc.) and the converter, mu st be less than 100 meters (328 ft.) long and comply with the IEEE 802.3ab 1000Base-T standard for Categ ory 5e or ab[...]

  • Page 26

    EKI-2741F-SX-LX User Manual 18 Second, insert the fiber cable of LC conn ector into the transceiver. Figure 2.10: LC connector to the transceiver To remove the LC connector from the trans ceiver, please follow the step s shown below: First, press the upper side of the LC con nector fr om the transceiver and pull it out to release. Figure 2.11: Remo[...]

  • Page 27

    19 Ch apter2 Second, push down the metal loop and pull the transceiver out by the plastic part. Figure 2.12: Pull out from the SFP module[...]

  • Page 28

    EKI-2741F-SX-LX User Manual 20 2.6 Power Connection The EKI-2741F/SX/LX support dual +12 ~ 48 V DC power inputs a nd power-fail relay output. Figure 2.13: Pin Assignment of the Power Connecto r You can connect an alarm i ndicator, buzzer or other signalin g equipment through the relay output. The relay opens if power input 1 or 2 fails ( “Open ?[...]

  • Page 29

    21 Ch apter2 Troubleshooting CHAPTER[...]

  • Page 30

    EKI-2741F-SX-LX User Manual 22 Chapter 3 Troubleshooting 1. Power Input Verify that is using the right power cord/ada pter (+12~48 V DC ), please don’t use the power adaptor with DC o utput voltage higher than 48V, or it will burn this converter down. 2. Cable Select the proper UTP/Fiber cable to construct your network. The single-mode converter [...]

  • Page 31

    23 Ch apter2 Pin Assignment & Wiring APPENDIX[...]

  • Page 32

    EKI-2741F-SX-LX User Manual 24 Appendix A Pin Assignment & Wiring It is suggested to adopt ELA/TIA as the wiring of the RJ-45. Figure A.1: RJ-45 Pin Assignment Figure A.2: EIA/TIA-568B Figure A.2: EIA/TIA-568A[...]