Go to page of
Similar user manuals
-
Switch
Agilent Technologies 8712ET
185 pages 1.45 mb -
Switch
Agilent Technologies U2751A
67 pages 2.8 mb -
Switch
Agilent Technologies B2201A
234 pages 1.24 mb -
Switch
Agilent Technologies E1364A
60 pages 1.07 mb -
Switch
Agilent Technologies U2121A-101
41 pages 1.05 mb -
Switch
Agilent Technologies 5185-5991
2 pages 0.26 mb -
Switch
Agilent Technologies 01664-97005
164 pages 1.97 mb -
Switch
Agilent Technologies 75000 SERIES B
244 pages 4.38 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Agilent Technologies 3499A/B/C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Agilent Technologies 3499A/B/C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Agilent Technologies 3499A/B/C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Agilent Technologies 3499A/B/C should contain:
- informations concerning technical data of Agilent Technologies 3499A/B/C
- name of the manufacturer and a year of construction of the Agilent Technologies 3499A/B/C item
- rules of operation, control and maintenance of the Agilent Technologies 3499A/B/C item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Agilent Technologies 3499A/B/C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Agilent Technologies 3499A/B/C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Agilent Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Agilent Technologies 3499A/B/C.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Agilent Technologies 3499A/B/C item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
How your 3499A/B/C T est System Benefits From Upgrading to the New 34980A Switch/Measure/Control System Application Note This application not e will describe differences and advant ages of t he new 34980A as compared to the 3499A/B/C. The 34980A Switch/Measure System masters switching, measurement, and control features by offering a superior select[...]
-
Page 2
2 List of 34980A Measurement Capabilities • T emperature measured with Thermocouples, RTDs and Thermistors • DC and AC volts • 2- and 4-wire Resistance • Frequency and Period • DC and AC current • 4 alarms for High/Low or both limits for each channel • Digital I/O • Analog outputs (DAC) The 34980A mainframe also includes f our 2-wir[...]
-
Page 3
3 Modules The 34980A implements a superior selection of switch topologies. The 34980A swit ch topologies are similar t o 3499A/B/C switch modules and include multiplex ers, matrixes, high-po w er , general purpose, and RF/micro wav e switches. Ho wev er , the 34980A modules hav e utilized the new est swit ch technology which enables a higher densit[...]
-
Page 4
4 Module T ype 34980A 3499A/B/C Multiplexer 34921A 40 Ch armature 300V 1A N2260A 40 Ch armature 200V 1A 34922A 70 Ch armature 300V 1A N2266A 40 Ch reed 200V .5A 34923A 40 Ch reed 200V .5A N2270A 10 Ch 1000V 1A 34924A 70 Ch reed 80V .5 44470A 10 Ch armature 250V 2A 34925A 40 Ch FET +/-80V .5A 44470D 20 Ch armature 250V 2A General Purpose 34937A 28 C[...]
-
Page 5
5 User Interface The 34980A of fers the most modern instr ument I/O options for inter facing a controller PC wit h the switch system: GPIB, USB and L AN. All three Input/Output inter face connections come standard with the 34980A mainframe. If you choose t o modify or upgrade your test system I/O, the 34980A is system ready. Y ou can also easily co[...]
-
Page 6
6 W eb Page Interface The 34980A comes wit h a built-in detailed instr ument w eb page that allo ws you t o remot ely connect and communicate with the mainframe and installed modules. Y ou establish a L AN connection, eit her directly between t he 34980A and PC, or from the 34980A to an existing Local Area Netw ork. The instrument W eb page resides[...]
-
Page 7
7 T able 4. Command comparisons 34980A 3499A/B/C Close channel 10 on the module in slot 3 ROUT e:CLOS (@3010) [ROUT e:]CLOS (@310) Scan channels 0 through 40 on the module in slot 1 ROUT e:SCAN (@1001:1040) [ROUT e:]SCAN (@100:140) and channel(s) rat her than only three digits as the 3499A/B/C uses. Also, for t he 3499A/B/C t he [ROUT e] in the com[...]
-
Page 8
8 Scan Feature The scan feature is a sequence of alternating swit ch closures and measurements. This feature is pro vided by bot h the 34980A and a 3499A/B/C combined wit h a DMM or ot her measurement instrument. The 34980A increases the measurement scan abilities and offers more than twice the number of scanned channels within one scan list compar[...]
-
Page 9
9 Monitor Feature The 34980A monit or feature allo ws you t o monit or readings acquired by the switch/measure system. Y ou can also monitor readings acquired wit h t he 34980A internal DMM. T o monitor a measurement from the front panel, simply select the channel and press eit her t he Measure [DMM] or [Channel] button to see a continually updated[...]
-
Page 10
10 Switch and Measurement Connections Most often, t est syst ems must be f lexible enough to be easily mov ed to a new location or modified for different devices under test. Having a remo vable wiring ter minal block or a pre-wired cable is optimal in t hese situations. The module’s terminal and/or cable can sim ply be remov ed and replaced with [...]
-
Page 11
11 Summary Although the 3499A/B/C Switch/Control system has been a great addition to many test systems, the new 34980A now offers an even better module selection plus measurement capability , standard PC connections f or communication, and is easy to connect to modules. The wide of fering of plug-in modules f or t he 34980A enables you to select a [...]
-
Page 12
12 Appendix A – Command Reference/Comparison 34980A Commands ABORt CALCulate :A VERage:AVERage? :A VERage:CLEar :A VERage:COUNt? :A VERage: MAXimum? :A VERage:MAXimum:TIME? :A VERage:MINimum? :A VERage:MINimum:TIME? :A VERage:PTPeak? :LIMit:LOW er :LIMit:LOW er? :LIMit:LOW er:ST A T e :LIMit:LOW er:ST A T e? :LIMit:UPPer :LIMit:UPPer? :LIMit:UPPe[...]
-
Page 13
13 :CURRent:AC :CURRent[:DC] :DIGital:ST A T e :DIGital:WIDTh :FREQuency :FRESistance :PERiod :RESistance :TEMPerature :TOT alize [:VOL T age]:AC [:VOL T age][:DC] CONFigure? DA T A :LAST? :POINts:EVENt:THReshold :POINts:EVENt:THReshold? :POINts? :REMove? DIAGnostic :DMM:CYCLes:CLEar :DMM:CYCles? :RELay CYCles:CLEar :RELay:CYCLes? DISPlay [:ST A T [...]
-
Page 14
14 :CURRent:AC? :CURRent[:DC]? :DIGital[:<width>]? :DIGital[:BYTE]:BIT? :FREQuency? FRESistance? :PERiod? :RESistance? :TEMPerature? :TOT alize? [:VOL T age]:AC? [:VOL T age][:DC]? MEMory :ST A T e:CA T alog? :ST A T e:DELete :ST A T e:NAME :ST A T e:NAME? :ST A T e:RECall:AUTO :ST A T e:RECall:AUTO? :ST A T e:RECall:SELect :ST A T e:RECall:S[...]
-
Page 15
15 :SCAN :SCAN:ADD :SCAN:REMove :SCAN:SIZE? SAMPle :COUNt :COUNt? SENSe :CURRent:AC :BANDwidth :BANDwidth? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :CURRent[:DC] :APERture:ENABled? :APERture :NPLC :NPLC? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :RESolution :RESolution? :ZERO:AUTO :DIGital:DA T A[:<width>]? :DIGital:DA T A[BYTE]:BIT? :FREQuency [...]
-
Page 16
16 :RANGe:AUTO? :RESolution :RESolution? :ZERO:AUTO :FUNCtion :FUNCtion? :PERiod:APERture :PERiod:VOL T age:RANGe :VOL T age:RANGe? :VOL T age:RANGe:AUTO :VOL T age:RANGe:AUTO? :PERiod:ZERO:AUTO :RESistance:APERture :APERture? :ALPERture:ENABled? :NPLC :NPLC? :OCOMpensated :OCOMpensated? :RANGe :RANGe? :RANGe:AUTO :RANGe:AUTO? :RESolution :RESoluti[...]
-
Page 17
17 [:DC]:NPLC? [:DC]:RANGe [:DC]:RANGe? [:DC]:RANGe:AUTO [:DC]:RANGe:AUTO? [:DC]:RESolution [:DC]RESolution [:DC]:ZERO:AUTO [:DC]:ZERO:AUTO? SOURce :CURRent[:LEV el] :CURRent[:LEV el]? :DIGital:DA T A[:<width>] :DIGital:DA T A[BYTE]:BIT :DIGital:ST A T e? :FUNCtion:CLOCk:EXT ernal:DIVisor :CLOCk[INT ernal]:PERiod :CLOCk:SOURce :CURRent:GAIN :[...]
-
Page 18
18 :ALARm:ENABle? :ALARm[:EVENt]? :MODule:ENABle :MODule:EVENt? :MODule:SLOT[n]:CONDition? :MODule:SLOT[n]:ENABle :MODule:SLOT[n][:EVENt]? :OPERation:CONDition? :OPERation:ENABle :OPERation:ENABle? :OPERation[:EVENt]? :PRESet :QUEStionable:CONDition? :QUEStionable:ENABle :QUEStionable:ENABle? :QUEStionable[:EVENt]? SYST em :ABUS:INT erlock:SIMulate[...]
-
Page 19
19 :TIME? :TIME:SCAN? :VERSion? TRACe:CA T alog? [:DA T A] [:DA T A]:DAC [:DA T A]:FUNCtion :DELete:ALL :DELete[:NAME] :FREE? :POINts? TRIGger :COUnt :COUNt? :DELay :DELay? :DELay:AUTO :DELay:AUTO? :SOURce :SOURce? :TIMer :TIMer? UNIT :TEMPerature :TEMPerature? IEEE-488.2 Common Commands *CLS *ESE *ESE? *ESR? *IDN? *OPC *OPC? *PSC *PSC? *RCL *RST *[...]
-
Page 20
Agilent T echnologies ’ T est and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can[...]