Go to page of
Similar user manuals
-
Blood Glucose Meter
Agilent Technologies U9072A cdma-2000
1403 pages 21.32 mb -
Blood Glucose Meter
Agilent Technologies AN 372-1
14 pages 0.26 mb -
Blood Glucose Meter
Agilent Technologies EN 60555
106 pages 0.53 mb -
Blood Glucose Meter
Agilent Technologies AN 372-2
8 pages 0.63 mb -
Blood Glucose Meter
Agilent Technologies EN 61000-3-2
106 pages 0.53 mb -
Blood Glucose Meter
Agilent Technologies EN 61000-3-3
106 pages 0.53 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Agilent Technologies AN 372-2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Agilent Technologies AN 372-2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Agilent Technologies AN 372-2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Agilent Technologies AN 372-2 should contain:
- informations concerning technical data of Agilent Technologies AN 372-2
- name of the manufacturer and a year of construction of the Agilent Technologies AN 372-2 item
- rules of operation, control and maintenance of the Agilent Technologies AN 372-2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Agilent Technologies AN 372-2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Agilent Technologies AN 372-2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Agilent Technologies service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Agilent Technologies AN 372-2.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Agilent Technologies AN 372-2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Agilent AN 372-2 Battery T esting Application Note An electronic load can be used to discharge batteries of various chemistries to determine actual capacity , capacity retention, and internal impedance.[...]
-
Page 2
2 Increasing demand for por table DC po wer has risen from impro vements in batt ery and mot or design technol- ogy. More than ev er before, portable DC powered products have become available in man y diverse applications. Rechargeable batt eries appear in all types of products from anal ytical electronic equipment to pow er tools and t o ys. In so[...]
-
Page 3
3 Sev en standard t est procedures 1 are used t o verify cer tain electrical char- acteristics of secondar y batt eries: 1. Rated capacity 2. Capacity retention 3. Effective internal resistance 4. Discharge rate effect on capacity at –20°C 5. Discharge rate effect on capacity at 23°C 6. Life cycle performance 7. Extended overcharge Other miscel[...]
-
Page 4
4 Capacity varies with the rate of dis- charge as sho wn in Figure 3. Testing for how discharge rate af f ects capacity is discussed later in more detail. Generally , low er discharge rates o ver longer periods of time yield higher values of tot al capacity. It is im por- tant to realize that since discharge rate affects how the value of C is deter[...]
-
Page 5
5 Effective Internal Impedance Batter y impedance is dependent on temperature, its st ate of charge, and the load frequency. The effectiv e internal im pedance is low er f or a full y charged batter y than it is f or a dis- charged one. Having a lo w inter nal resistance is v er y im por tant when the batter y must support a high current for a shor[...]
-
Page 6
6 Miscellaneous T ests In addition to t he tests already men- tioned, there are also other miscella- neous tests per f ormed on nick el- cadmium batteries. These t ests usually invol ve high rate charge and/or discharge. High rate discharge and charge of nickel-cadmium batteries is possible with t oda y’s ne w and better designed cells having adv[...]
-
Page 7
7 From the various tests described so far , w e can see some common requirements for test equipment. All the tests require a discharge cycle using a constant current. A const ant discharge cur rent cannot be att ained with a simple resist or because the batter y voltage changes as current is drawn from it. An active device is required, such as an e[...]
-
Page 8
Agilent T echnologies Electronic Loads are ideally suited for batter y test applications. Their man y f eatures ma k e t he test system easy to config- ure and pro vide safe, reliable, and repeatable operation. The A gilent 6060A Electronic Load and 6050A Electronic Load mainframe hav e the required constant-current modes as well as constant-resist[...]