Aiphone GTW-LC manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Aiphone GTW-LC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Aiphone GTW-LC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Aiphone GTW-LC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Aiphone GTW-LC should contain:
- informations concerning technical data of Aiphone GTW-LC
- name of the manufacturer and a year of construction of the Aiphone GTW-LC item
- rules of operation, control and maintenance of the Aiphone GTW-LC item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Aiphone GTW-LC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Aiphone GTW-LC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Aiphone service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Aiphone GTW-LC.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Aiphone GTW-LC item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SER VICE MANUAL INST ALLA TION & OPERA TION MANUAL 0311 A OI GTW-LC GT System Lift contr ol adaptor GTW -LC[...]

  • Page 2

    - 2 - General Pr ohibitions Pr ohibition to Dismantle the Unit Pr o h ib i ti o n o n S ub j ec t in g t h e U ni t t o W a t er General Precautions W ARNING (Negligence could result in death or serious injury .) 1. Do not dismantle or alter the unit. Fire or electric shock could result. 2. The unit must be installed and wired by a qualified techn[...]

  • Page 3

    - 3 - 1 SYSTEM CONFIGURA TION 1-1 1-1 System Configuration a. GT expanded system (For details, see the GT Series Installation & Op- eration Manual.) Make sure to use GT -BCX, GT -D A(-L), GT -NS(-V), GT -DM(V). [1] Expanded Bus control unit GT -BCX [2] Distribution terminal (junction): Not included [3] Lift control adaptor GTW -LC Relay contac[...]

  • Page 4

    - 4 - 2 CONTENTS 3 NAMES Contents Lift control adaptor GTW -LC (mounting bracket is included) Names [1] Bus line terminal [2] ID setting switch [3] Relay output terminal [4] Lock release lev er GTW -LC [1] [4] [3] [2] [3][...]

  • Page 5

    - 5 - 4 MOUNTING Mounting [1] Din rail [2] Lock release lev er Mount GTW -LC to the Din rail. * T o remove GTW -LC, pull the lock release lever do wn. GTW -LC cannot be mounted directly to the wall surface. GTW -LC [1] [2] [1][...]

  • Page 6

    - 6 - 5 WIRING 1P NP 1P NP 1P NP [5] [4] GT-BC R1 4 2 3 1 R2 [2] DP R1 R2 + – R1 R2 GT -BCX R Y20 R Y1 GTW-LC #8 Max. 8 R1 R2 GT -BCX R Y20 R Y1 GTW-LC #1 to Lift controller #9 to #16 (max. 8) 1P NP 1P NP 1P NP 1P NP 1P NP 1P NP 1P NP GTW-LC [3] [3] GT-BCX [1] R1 R2 GTW-LC GT Expanded System a + – ON 123 4 ON 123 4 ON 123 4 ON 123 4 #1 #2 #3 #4[...]

  • Page 7

    - 7 - Wiring a. GT expanded system (For details, see the GT Series Installation & Op- eration Manual.) [1] Expanded Bus control unit GT -BCX [2] Distribution terminal (junction): Not included [3] Lift control adaptor GTW -LC Maximum 16 adaptors (up to 8 adaptors per trunk) • ID: ID setting switch (factory setting is #1) Make sure to set corre[...]

  • Page 8

    - 8 - 6 SETTING UP 6-1 Setup tool * Completing settings with the setup tool is required. 1. Install the setup tool in the PC (W indows 7/VIST A/XP ®) beforehand, and then enter the resident information. * For details on the setup tool, refer to the GT Series Installation & Op- eration Manual. Sav e programmed data and resident information data[...]

  • Page 9

    - 9 - 6-2 6-3 Lift Control 1 [1] GTW -LC ID [2] Select “ ON ” or “ OFF ” for the GTW -LC connection. [3] Select “ N.O. ” or “ N.C. ” for the Output T ype. [4] Set the T imer . The time setting range is “ 1 to 600 ” sec. (one second increments) • Clicking the upper spin button will increase the time setting, and clicking the lo[...]

  • Page 10

    - 10 - 6-5 Combine Data The data entered in the GT -BCX can be combined with the data entered in the GT -NS(V), GT -MK or GT -DM(V), and this data can be saved as master data. * Import the data entered into the GT -NS(V), GT -MK, GT -DM(V) and GT -BCX before this process. 1. Select and open the corresponding data with “ Open ” in the “ File ?[...]

  • Page 11

    - 11 - 8 TECHNICAL PRECA UTIONS 9 SPECIFICA TIONS T echnical precautions • Operating temperature: 0 ° C to + 40 ° C ( + 32 ° F to + 104 ° F) • Repair requests: When units do not operate properly , contact a qualified technician for service. Specifications • Power supply: Supplied by GT -BC • Relay contacts: 20 AC/DC 24 V , 500mA, N.O.[...]

  • Page 12

    - 12 - Aiphone warrants its products to be free from defects of material and workmanship under nor - mal use and service for a period of two years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defectiv e and under w arranty . Aiphone[...]