Go to page of
Similar user manuals
-
Intercom System
Aiphone C-123LW
4 pages 0.7 mb -
Intercom System
Aiphone JF-2HD
16 pages 4.75 mb -
Intercom System
Aiphone MA-1A
6 pages 0.28 mb -
Intercom System
Aiphone DE-UR
4 pages 0.21 mb -
Intercom System
Aiphone IBG-2AD
4 pages 0.26 mb -
Intercom System
Aiphone GF-3F
8 pages 0.54 mb -
Intercom System
Aiphone YAW-RB
8 pages 0.4 mb -
Intercom System
Aiphone KC-1GRD
4 pages 1.25 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Aiphone IS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Aiphone IS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Aiphone IS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Aiphone IS should contain:
- informations concerning technical data of Aiphone IS
- name of the manufacturer and a year of construction of the Aiphone IS item
- rules of operation, control and maintenance of the Aiphone IS item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Aiphone IS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Aiphone IS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Aiphone service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Aiphone IS.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Aiphone IS item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation, and keep it in a safe place for future reference. Also read the SETTING MANUAL and OPERA TION MANUAL on the bundled CD-ROM. When the installation is completed, con fi gure the system by following the SETTING MANUAL. Oth[...]
-
Page 2
2 CONTENTS PRECAUTIONS ................................ 3 W ARNING ....................................... 3 CAUTION ........................................ 3 GENERAL PRECAUTIONS ............ 3 Notes on using this system .......... 4 Notices ............................................ 4 SYSTEM CONFIGURA TIONS .......... 4 Entire system ..........[...]
-
Page 3
3 PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to W ater General Precautions W ARNING Negligence could result in death or serious injury . 1. Do not dismantle or alter the unit. Fire or electric shock could result. 2. Keep the unit away from water or any other liquid. Fire or electric shock c[...]
-
Page 4
4 SYSTEM CONFIGURA TIONS The IS system is a commercial and security video intercom system especially designed for applications in facilities such as of fi ce buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications systems, the IS system can be used as a video door entry [...]
-
Page 5
5 System con fi guration examples ■ Standard (IP) system The following is an example of standard (IP) system for controlling security and communication for facilities. A site must be con fi gured with an IP-based system. • A standard (IP) system can consist of local systems and IP units. • A local system (Hard wired network system) without [...]
-
Page 6
6 CONNECTIONS System connection diagram The following is an example of standard (IP) system connection diagram. Refer to page 9 to 26 for details about each unit connection. * IP IS-IPC *1 IS-CCU IS-RCU IS-SCU IS-RS IS-RS IS-RS IS-MV IS-DV/IS-DVF /IS-SS IS-DV/IS-DVF /IS-SS IS-MV PT PT IS-SS IS-PU-UL IS-PU-S IS-PU-UL IS-PU-S IS-PU-UL IS-PU-S IS-PU-U[...]
-
Page 7
7 IP IP IS-IPC* 1 IS-RCU IS-RS IS-IPMV IS-IPDV /IS-IPDVF IP PT IS-SS IP PS-2420/D/UL/S* 2 PS-2420/D/UL/S* 2 IS-PU-UL IS-PU-S IS-PU-UL IS-PU-S PoE PoE AC transformer Maximum number of each unit connectable to a "local system" and a site of "standard (IP) system" Category Model name T ype Max. number Local system Standard (IP) sys[...]
-
Page 8
8 Cables Cables and connectors are not included with the products. Refer to page 9 to 26 for details about each unit connection. Notes on cables Pair4 Pair3 12345678 12345678 Pair2 Pair1 T568A Pair4 Pair2 Pair3 Pair1 T568B How to connect or disconnect stranded wires. 8mm (3/8") Notes on CA T5e/6 cables Do not bend the cables to an extent where[...]
-
Page 9
9 UNIT DET AILS Control unit common information The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (IS- * RCU) and IP control unit (IS-IPC). ■ Accessories ・ Mounting bracket × 2 ・ Installation manual (a booklet) *1 × 1 ・ Screw (for wall-mounting) × 4 ・ CD-ROM (In[...]
-
Page 10
10 Central control unit ( IS-CCU ) ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Central control unit (IS-CCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 800mA Ambient temperature 0 - 40°C (+32°F - +104°F) T alk channels ・ Video channels Local sy[...]
-
Page 11
11 ■ Connections 1CX1 1CX2 M1 M2 1MX1 1MX2 1MX3 2MX1 2MX2 2MX3 M3 M4 D1 D2 IP1 LAN IP2 IP3 D3 D4 2CX1 2CX2 3CX1 3CX2 4CX1 4CX2 P1 P2 P3 P4 L1 L2 L3 L4 L5 L6 L7 L8 S1 E S2 E S3 E S4 E IS-RCU MASTER ST ATION IS-SCU IS-IPC DC48V DOOR/SUB ST ATION VIDEO/AUDIO P A OUTPUT (600 Ω ) CONT ACT INPUT CHIME INPUT (600 Ω ) ETHERNET VIDEO OUTPUT CONT ACT OUT[...]
-
Page 12
12 Add-on control unit ( IS-SCU ) ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Add-on control unit (IS-SCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 1.2A Ambient temperature 0 - 40°C (+32°F - +104°F) T alk channels ・ Video channels Local syste[...]
-
Page 13
13 ■ Connections M1 M2 M3 M4 M5 M6 M7 M8 D1 D2 MX1 MX3 ID 1 2 MX2 D3 D4 D5 D6 D7 D8 P1 P2 P3 P4 L1 L2 L3 L4 MASTER ST ATION IS-CCU DC48V VIDEO/AUDIO DOOR/SUB ST ATION P A OUTPUT (600 Ω ) VIDEO OUTPUT CONT ACT OUTPUT (AC/DC24V 0.5A) V1 V2 CA T5e/6 300m (980') CA T5e/6 300m (980') 15m(50') 200m (650') CA T5e/6 150m (490') [...]
-
Page 14
14 Room sub control unit ( IS-RCU ) ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Room sub control unit (IS-RCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 1.8A Ambient temperature 0 - 40°C (+32°F - +104°F) T alk channels Local system: 2 talk chann[...]
-
Page 15
15 ■ Connections C1 C2 CX1/IP1 ID 1 2 3 4 CX2/IP2 C3 C4 C5 C6 C7 C8 C9 C10 C1 1 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 C26 C27 C28 C29 C30 P1 P2 P3 P4 L1 L2 L3 L4 IS-CCU/ IS-IPC DC48V AUDIO DOOR/SUB ST ATION P A OUTPUT (600 Ω ) CONT ACT OUTPUT (AC/DC24V 0.5A) CA T5e/6 300m (980') 15m (50') 200m (650') CA T5e/6 150[...]
-
Page 16
16 IP control unit ( IS-IPC ) IP : This unit is needed to connect a local system to a standard (IP) system. ■ Part names NO TE: The illustration of the unit may differ from the actual one. ■ Speci fi cations IP control unit (IS-IPC) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 105mA Ambient temperature 0[...]
-
Page 17
17 ■ Connections IP1 IP2 IP3 LAN IS-RCU IS-CCU DC48V ETHERNET CO TELEPHONE 10m (33') 10m (33') 15m (50') 2C IP1 IP2 IP3 φ 0.8-1.2mm (20-16 AWG) IP1 IP2 IP3 IS-RCU IS-CCU CA T5e/6 (x3) 10BASE-T 100BASE-TX 100m (330') CX1/IP1 CX2/IP2 CA T5e/6 (x2) P *3 *1: When connecting a central control unit (IS-CCU) to this unit, connect it[...]
-
Page 18
18 Color monitor master station (IS-MV) For the part names and their functions, see the OPERA TION MANUAL. * ■ Accessories ・ Mounting bracket × 1 ・ Name card × 1 ・ Desktop stand × 1 ・ Screw (15mm (5/8"), for wall-mounting) × 4 ・ Tie-wrap × 1 ・ Screw (25mm (1"), for gang box) × 4 ・ Name plate × 1 ・ Screw (10mm (7/1[...]
-
Page 19
19 When mounting on a desktop stand 30 r 45 r 60 r ■ Connections M V V A A VIDEO OUTPUT AUDIO OUTPUT M1 M4 CA T5e/6 Coax 2C M1 M8 CA T5e/6 P NP NTSC NO TES: Do not use the unoccupied terminals and ports for other purposes. • In order to prev ent miswiring, label both ends of each cable with the unit and terminal names to which they are to be co[...]
-
Page 20
20 V andal-resistant video door station (IS-DV , IS-DVF), V andal-resistant audio door station (IS-SS) ■ Accessories ・ Screw (for wall-mounting) × 4 (IS-DV only) ・ Special screwdriver × 1 ・ Anchor × 4 (IS-DV only) ・ Back box × 1 (IS-DVF and IS-SS only) ・ T ransparent name plate × 2 (IS-DV and IS-DVF only) ・ China RoHS paper × 1 [...]
-
Page 21
21 ■ Mounting IS-DV (surface-mount) ABCDEFG IS-DVF ( fl ush-mount), IS-SS ( fl ush-mount) e.g.) IS-DVF Special screwdriver (included) Loosen T ighten V andal-resistant front panel 81 mm (3-1/4'') 194 mm (7-1 1/16'') W ater escape holes Do not block the holes. Ø 6 mm (Ø 1/4") 35 mm (1-3/8") Anchor x 4 (included) S[...]
-
Page 22
22 ■ Connections (IS-DV and IS-DVF) D NO COM NC PT 300m (980') D1 D4 CA T5e/6 300m (980') D1 D8 CA T5e/6 φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') *1: Output speci fi cations Output method N/O or N/C dry closure contact V oltage between terminals 24V AC, 0[...]
-
Page 23
23 ■ Connections (IS-SS) D NC COM NO PT 300m (980') D1 D4 CA T5e/6 300m (980') D1 D8 CA T5e/6 300m (980') C1 C30 CA T5e/6 φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') *1: Output speci fi cations Output method N/O or N/C dry closure contact V oltage betwe[...]
-
Page 24
24 Room sub station (IS-RS) ■ Accessories ・ Mounting bracket × 1 ・ Screw (for gang box) × 2 ・ Screw (for wall-mounting) × 2 ・ China RoHS paper × 1 ・ Tie-wrap × 1 ■ Mounting <Back wiring> <Surface wiring> When a 1-gang box is not mounted, the cable and wires can be routed to the top of the unit. Cut a cable inlet on th[...]
-
Page 25
25 ■ Connections C SP SP S SE NO COM P AGING CONT ACT IN CONT ACT OUT 150m (490') D1 D4 CA T5e/6 150m (490') D1 D8 CA T5e/6 150m (490') C1 C30 CA T5e/6 2C 2C P NP 2C φ 0.65-1.2mm (22-16 AWG) 15m (50') φ 0.65-1.2mm (22-16 AWG) 15m (50') φ 0.65-1.2mm (22-16 AWG) 15m (50') *1: Output speci fi cations Output method N[...]
-
Page 26
26 Power supply unit (IS-PU-UL and IS-PU-S) ■ Accessories ・ AC cord × 1 (included in the package of this power supply unit) ・ Precaution & mounting instruction sheet (paper) × 1 ・ China RoHS paper × 1 (IS-PU-S only) ■ Mounting ■ AC cord requirements T ype: Must comply with requirements set out by the Safety Approval/Certi fi cat[...]
-
Page 27
27 TECHNICAL DA T A AND PRECAUTIONS T echnical data Operating temperature: • Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC), Master station (IS-MV), Room sub station (IS-RS), Power supply unit (IS-PU-UL, IS-PU-S) 0 - 40°C (+32°F - +104°F) Door station (IS-DV , IS-DVF , IS-SS) -10 - 60°C (+14°F - +140°F) Dimensions: • Control unit (IS-CCU, [...]
-
Page 28
AIPHONE CO., LTD., NAGOYA, JAPAN AIPHONE CORPORATION, BELLEVUE, WA, USA AIPHONE S.A.S., LISSES-EVRY, FRANCE http://www.aiphone.net/ W ARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two years after delivery to the ultimate user and will repair free of charge or r[...]