Go to page of
Similar user manuals
-
Intercom System
Aiphone IC-DL3
4 pages 0.35 mb -
Intercom System
Aiphone MA-1A
6 pages 0.28 mb -
Intercom System
Aiphone JF-1MD
8 pages 1.53 mb -
Intercom System
Aiphone TAR-3
4 pages 0.17 mb -
Intercom System
Aiphone 514426 A 0611YZ
18 pages 1.34 mb -
Intercom System
Aiphone TD-6H/B
12 pages 0.7 mb -
Intercom System
Aiphone VC-58MT
8 pages 0.64 mb -
Intercom System
Aiphone NEM-20/C
16 pages 0.79 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Aiphone LEF-3L, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Aiphone LEF-3L one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Aiphone LEF-3L. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Aiphone LEF-3L should contain:
- informations concerning technical data of Aiphone LEF-3L
- name of the manufacturer and a year of construction of the Aiphone LEF-3L item
- rules of operation, control and maintenance of the Aiphone LEF-3L item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Aiphone LEF-3L alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Aiphone LEF-3L, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Aiphone service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Aiphone LEF-3L.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Aiphone LEF-3L item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
– 1 – - SUPPLEMENT TO LEF INSTRUCTIONS - The LEF-3L is a compact, wall or desk mount master station able to selectively release a door or call up a camera. Used with any LE-(except LEF-3,5 and 10) or LS-series (North America only) remote station, communication can be established with each station by selecting the channel on the master station. [...]
-
Page 2
– 2 – Wire Refer ence Chart (North America only) Standard Communication With selective door release and/ or camera call-up Model # # of Conductors Wire # (22A WG) Wire # (18A WG) # of Conductors Wire # (22A WG) LEF-3L 9 822210 x 12 822212 LE-A 3 822203 821803 x x LE-D 3 822203 821803 x x LE-D A 3 822203 821803 x x 1 NAMES & FEA TURES FEA [...]
-
Page 3
– 3 – 2 SYSTEM OUTLINE & COMPONENTS ■ System outline Individual Components for LEF-3L System: * : North America only *LS-NVP/C Va ndal and weather resistant sub station, white powder coated (optional SBX-NVP surface box) *LE-SS Stainless Steel 2-Gang sub station *LE-SSR Stainless Steel 2-Gang sub station with red mushr o[...]
-
Page 4
– 4 – 2 SYSTEM OUTLINE & COMPONENTS (Cont.) LE-D/LE-DA TERMINAL DEFINITIONS: 1 Station number E Common communication − Negative *LS-NVP/C TERMINAL DEFINITIONS: Red Station number Black Common communication Green Negative *LE-SS(R)/LE-SS-1G COLOR CODE: Red Station number Black Common communication Green Negative * [...]
-
Page 5
– 5 – Wire: · Shielded wire is str ongly recommended. Use the proper gauge for the distance being run. · Wiring between masters must be a multi-conductor cable. If more than one cable is used to connect masters, the "E", "C", and number terminal wires must be in the same jacketed cable. If necessary , run multiple "E&[...]
-
Page 6
– 6 – 2 SYSTEM OUTLINE & COMPONENTS (Cont.) ■ Call tone adjustment 3-position volume switch, located under Operation plate. Adjusts call tone volume to low (far left), medium, high (far right). ■ Selector switch for Call T one in Occupied Mode LEF surface mount master stations are set in the "B" position fr om the factory . Th[...]
-
Page 7
– 7 – 3 MOUNTING LEF-3L intercom SINGLE-GANG BOX 83.5mm, 3-5/16" 2 screws supplied Chassis Loosen Operation plate Directory card ★ 2 ★ 1 UP 83.5mm, 3-5/16" SINFGLE-GANG BOX Mounting bracket 2 screws supplied (LE-A) Unplug while installing OFF OCCUPIED VOL. VOICE TALK AIPHONE LEF-3L 12 3 Station- selector (3) Station Call-in LE[...]
-
Page 8
– 8 – 4 WIRING DIAGRAMS - Most Common Applications 1 x LEF-3L, 3 x Door Stations WIth Selective Door Release 2 x LEF-3L, 2 x Door Stations With Master to Master communication shown on channel 3 With Selective Door Release 2 x LEF-3L, 1 x Door Station With Master to Master Communication Door Station wired on each station's own number termin[...]
-
Page 9
– 9 – 4 WIRING DIAGRAMS - Multiple Masters for Door Answering LEF-3L System with External Signaling (RY -AC) One door station with the ability to activate a separate doorbell Shown with external signaling and door release relays LEF-3L System with External Signaling (RY -AC) Selective external signaling relay outputs for each door station call-[...]
-
Page 10
– 10 – 5 OPERA TIONS & SPECIFICA TIONS OPERA TIONS: ■ Calling a master or sub: 1. Depress a station selector button 1 ~ 3. 2. Press the T ALK button to speak, and release to listen to the reply . 3. T o conclude, depress OFF button. ■ Receiving a call from a sub station: 1. Sub station calls in with tone and LED, which stays lit for 20 [...]
-
Page 11
– 11 – WIRING DIST ANCE: Dimensions (HxWxD): 180H x 143W x 53.5D (mm). 7-1/16" x 5-5/8" x 2-1/8" RY -P A Contact Rating: 1A, 110V AC or 24V DC RESTRICTIONS · Only one power supply can be used on one system. · Up to 4 masters can be connected on the multiple masters confi guration, or up to 3 masters on the intermix confi gura[...]
-
Page 12
– 12 – 6 TROUBLESHOOTING GUIDE (Cont.) ENTRY # PROBLEM POSSIBLE CAUSE SOLUTION 5 No master -to-master communication. C terminals mis-wired between masters. Communication between masters is carried on the # wire of the calling master to the C terminal of the receiving master . Verify that the C terminal of the master that is being called is actu[...]