Air King AIK26YL manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Air King AIK26YL, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Air King AIK26YL one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Air King AIK26YL. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Air King AIK26YL should contain:
- informations concerning technical data of Air King AIK26YL
- name of the manufacturer and a year of construction of the Air King AIK26YL item
- rules of operation, control and maintenance of the Air King AIK26YL item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Air King AIK26YL alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Air King AIK26YL, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Air King service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Air King AIK26YL.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Air King AIK26YL item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    READ AND SA VE THESE INSTRUCTIONS READ CAREFULL Y BEFORE A TTEMPTING TO ASSEMBLE, INST ALL, OPERA TE OR MAINT AIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMA TION. F AILURE TO COMPL Y WITH INSTRUCTIONS COULD RESUL T IN PERSONAL INJURY AND/OR PROPER TY DAMAGE! RET AIN INSTRUCTIONS FOR FUTURE REFERENCE. GENERAL [...]

  • Page 2

    INST ALLA TION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing for Fan Installation 1. When selecting fan mounting location, the following criteria should be considered: a) Mounting to minimize noise generated by fan operation: Mounting the fan as far as possible from the inta[...]

  • Page 3

    www .airkinglimited.com 5S7635037 New 10-06 3 of 16 NOTE: If drywall or ceiling material will be thicker than 5/8" the height of the housing will need to be adjusted to compensate and the locator tabs will need to be bent even with the housing to allow the grill collar to be flush with the finished ceiling material. 2a. Keyhole Installation: U[...]

  • Page 4

    www .airkinglimited.com 5S7635037 New 10-06 4 of 16 SECTION 6 Ducting CAUTION: ALL DUCTING MUST COMPL Y WITH LOCAL AND NA TIONAL BUILDING CODES. NOTE: Insulated ducting is required for bathroom exhaust applications, where ducting passes through unconditioned space or where noise is a factor . Failure to use insulation could result in excessive cond[...]

  • Page 5

    www .airkinglimited.com 5S7635037 New 10-06 5 of 16 CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NA TIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INST ALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. 1. Remove the screws securing the terminal box cover plate[...]

  • Page 6

    www .airkinglimited.com 5S7635037 New 10-06 6 of 16 Figure 17 Lamp Grill Housing Ceiling/W all T roubleshooting Guide T rouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. 1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker . 1b. Wiring is not connected properly . 1b. T urn off p[...]

  • Page 7

    LIMITED WARRANTY All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/or material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods are guaranteed for five years from the date of purchase against defects in work[...]

  • Page 8

    www .airkinglimited.com 5S7635037 New 10-06 8 of 16 # Qty . Description Replacement Part # 1 1 Motor - AIK14XL 5S7635038 1 Motor - AIK26YL 5S7635002 2 1 Cover Plate - AIK14XL 5S7635029 1 Cover Plate - AIK26YL 5S7635030 3 2 Screw 5S7699021 4 Screw 5S7699023 4 1 Mounting Bracket 5S7635035 5 3 Grommet 5S7699020 6 3 Screw 5S7699024 7 1* Y T ransition -[...]

  • Page 9

    LIRE ET CONSER VER CES INSTRUCTIONS LIRE SOIGNEUSEMENT A V ANT DE TENTER D’ASSEMBLER, INST ALLER, OPÉRER OU DE RÉP ARER LE PRODUIT DÉCRIT . PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERV ANT TOUTE L ’INFORMA TION DE SÉCURITÉ. F AILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSUL TER EN BLESSURE PERSONNELLE GRA VE ET/OU EN DOMMAGE À LA PROPR[...]

  • Page 10

    Support Montant Figure 2 V entilateur Vis INSTRUCTIONS D’INST ALLA TION A VER TISSEMENT : VOUS ASSURER QUE L ’ALIMENT A TION EST COUPÉE AU P ANNEAU DE SERVICE A V ANT DE COMMENCER L ’INST ALLA TION. SECTION 1 Préparation en prévision de l’installation du ventilateur 1. Lorsque vous choisissez l’emplacement pour l’installation du vent[...]

  • Page 11

    www .airkinglimited.com 5S7635037 New 10-06 11 of 16 REMARQUE : Si l’épaisseur de la paroi sèche ou du matériel du plafond est de plus de 15,88 mm, la hauteur du châssis devra être ajustée pour compenser et les onglets de repère pliés à égalité du châssis de sorte que le collet de la grille soit à effleurement du matériel de plafond[...]

  • Page 12

    www .airkinglimited.com 5S7635037 New 10-06 12 of 16 REMARQUE : Si l’épaisseur de la paroi sèche ou du matériel du plafond est de plus de 15,88 mm, la hauteur du châssis devra être ajustée pour compenser et les onglets de repère pliés à égalité du châssis de sorte que le collet de la grille soit à effleurement du matériel de plafond[...]

  • Page 13

    www .airkinglimited.com 5S7635037 New 10-06 13 of 16 3. Insérez l’arbre du clapet dans le trou perforé à l’étape 2. Placez la rondelle, la poignée et ensuite l’écrou à oreille dans l’arbre (Figure 12) . 4. Ajustez le clapet de sorte à équilibrer le débit d’air et serrez l’écrou à oreille pour le fixer en place . SECTION 8 C?[...]

  • Page 14

    www .airkinglimited.com 5S7635037 New 10-06 14 of 16 4. Installez à nouveau le couvercle électrique en vous assurant que tous les fils sont bien rentrés à l’intérieur du boîtier et qu’ils ne seront pas pincés. SECTION 10 Finaliser l’installation 1a. Modèles avec lumière à halogène : Installez la lampe à halogène incluse en l’in[...]

  • Page 15

    www .airkinglimited.com 5S7635037 New 10-06 15 of 16 GARANTIE LIMITÉE T ous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chauffere[...]

  • Page 16

    www .airkinglimited.com 5S7635037 New 10-06 16 of 16 # de pièce # Qté. Description de r em placement 1 1 Moteur - AIK14XL 5S7635038 1 Moteur - AIK26YL 5S7635002 2 1 Plaque de finition - AIK14XL 5S7635029 1 Plaque de finition - AIK26YL 5S7635030 3 2 Vis 5S7699021 4 Vis 5S7699023 4 1 Support de montage 5S7635035 5 3 Passe-câble 5S7699020 6 3 Vis 5[...]