Go to page of
Similar user manuals
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Air King AK5000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Air King AK5000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Air King AK5000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Air King AK5000 should contain:
- informations concerning technical data of Air King AK5000
- name of the manufacturer and a year of construction of the Air King AK5000 item
- rules of operation, control and maintenance of the Air King AK5000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Air King AK5000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Air King AK5000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Air King service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Air King AK5000.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Air King AK5000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Model 5000/6000 Model 5000/6000 FLOW-THROUGH FURNACE HU M IDIFIER Warranty Maintenance Troubleshooting Guide[...]
-
Page 2
W ARRANTY The manufacturer guarantees the for the period of one year from the date of purchase, the product will be free of defects in workmanship and/or material. As well the manufacturer offers a life time warranty on the flow through humidifier body . During the warranty period, we will replace or repair any defective part at no charge if the pr[...]
-
Page 3
4. The inlet filter is located inside the black orifice fitting . Using a pointy object (i.e. nail), remove the inlet. 5. The filter should be fairly clean and free of depree, 6. Replace or clean the inlet filter if required. If punctured or damaged, replace before operating the humidifier . Remember this filter protects the orifice fitting and sol[...]
-
Page 4
14. Reinstall the solenoid valve onto the humidifier side, feed the flexible black water supply tube back through the humidifier side, reinstall the humidifier side (if removed) onto the humidifier body and secure in place, reconnect the water supply to the solenoid valve, replace the humidifier’s front cover and secure in place, turn back on the[...]
-
Page 5
5 Model 5000/6000 Flow Through Humidifiers Component Item Description P arts List/ Humidifier Model Component Number W arranty P eriod Recommended Maintenance Duct Mount Humidity Sensor 6000 29 1 year Replace as required. Humidisense Electronic Humidifier Control 5000/6000 Not Shown 1 year Replace as required. – PN 011109001 Solenoid V alve Assem[...]
-
Page 6
6 WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE 010912000 1 /per d r ain ins er t 3 2 3 * S pe c i fy b r and 2 8 2 6 2 7 2 5 2 4 1 3 1 8 22 21 20 19 1 6 1 7 1 5 1 4 8 11 12 10 9 6 7 5 4 0109 3 7 000 1 /per in l e t w at er f i l t er 10 - 3 2 p l asti c s c re w 1 / 4 " w at er t u b e b r ass c om pre ssi o n n u t n y l o n f err u l e b r as[...]
-
Page 7
7 Model 5000/6000 Flow Through Humidifiers 3 drain insert 1/p er 0 1 09 1 2000 1 5 f eet / u nit 3 f eet / u nit 1 0 f eet / u nit in l et w ater f i l ter 2 3 * S p e c i f y b rand 2 8 2 7 2 6 2 5 2 4 n y l o n f err u l e b rass c o m p ressi o n n u t b rass insert 1/ 4 " w ater t u b e 1 0 - 3 2 p l asti c s c re w 1 3 1 8 22 2 1 20 1 9 1[...]
-
Page 8
TROUBLE SHOO TING GUIDE MODEL 5000 AND 6000 HUMIDIFIERS PROBLEM : NOT ENOUGH HUMIDITY POSSIBLE CAUSE : Humidistat set too low . REMEDY : T urn up the humidistat. POSSIBLE CAUSE : Humidifier has only been installed for a few days. REMEDY : If you have just installed the humidifier it can take anywhere from 3 to 4 weeks to build up the humidity level[...]
-
Page 9
REMEDY : • Adjust bypass damper to fully open position. • Ensure the bypass tube is fully stretched out tight. • F urnace filter is dirty and needs replacement. • Bypass tube and humidifier not installed parallel, use hard ducting – use hard ducting for any elbows – take the most direct route when ducting . • The bypass tube or humidi[...]
-
Page 10
• The bypass tube or humidifier is installed in front of air- conditioning coils or is blocked in some other way – move to another location and ensure maximum air flow . • The fan delay on your furnace is not set properly and the furnace fan is shutting off too early when the air is still hot. Y ou should discuss with a HV AC professional to [...]
-
Page 11
POSSIBLE CAUSE : The humidifier is not turning off when the furnace is turning off . REMEDY : See section above for solution. If the unit is running when the furnace is not in heating mode then very little water will be evaporated and most of the water will be going down the drain. POSSIBLE CAUSE : The unit is working properly and the furnace is su[...]
-
Page 12
MODEL 6000 HUMIDIFIERS ONL Y PROBLEM : THE DIGIT AL HUMIDIST A T KEEPS RESET TING TO THE DEFAUL T SET TINGS. POSSIBLE CAUSE : P ower source (transformer) is plugged into an outlet which is being shut off or turns off via a switch. REMEDY : Relocate the transformer to an outlet which cannot be turned off – if you have a renovated basement the outl[...]
-
Page 13
MODEL AK5000 AK5500 & AK7000 SUPPLEMENTAL INSTRUCTION SHEET WARNING: THIS UNIT IS INTENDED TO BE INSTALLED BY AN LICENCED HVAC PROFESSIONAL – FOR THIS UNIT TO OPERATE PROPERLY THE SUPPLIED 24 VOLT TRANSFORMER MUST BE INTERLOCKED WITH THE FURNACE HEATING CYCLE – THE 24 VOLT TRANSFORMER SHOULD BE ENERGIZED ONLY WHEN THE FURNACE IS IN HEATING [...]
-
Page 14
FEUILLE D’INSTRUCTION COMPLÉMENTAIRE, MODÈLES AK5000, AK5500 ET AK7000 MISE EN GARDE : CET APPAREIL EST CONÇU PO UR ÊTRE INSTALLÉ PAR UN PROFESSIONNEL CVC AUTORISÉ SOUS LICENCE – POUR QUE CET A PPAREIL FONCTIONNE CONVENABLEMENT, LE TRANSFORMATEUR DE 24 VOLTS FOURNI DOIT ÊTRE INTERVERROUILLÉ AVEC LE CYCLE DE CHAUFFAGE DE LA FOURNAISE - L[...]