Alesis EC-2 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Alesis EC-2, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Alesis EC-2 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Alesis EC-2. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Alesis EC-2 should contain:
- informations concerning technical data of Alesis EC-2
- name of the manufacturer and a year of construction of the Alesis EC-2 item
- rules of operation, control and maintenance of the Alesis EC-2 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Alesis EC-2 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Alesis EC-2, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Alesis service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Alesis EC-2.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Alesis EC-2 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    EC-2 96kHz Sample Rate Upgrade A/D and D/A Converter Cards for the ADAT HD24 Hard Disk Recorder O WNER ’ S M ANUAL V ERSION 1.0 A PPLIES TO ADAT HD24 SOFTWARE V ERSION 1.05 AND ABOVE[...]

  • Page 2

    EC-2 96kHz A/D/D/A upgrade • appendix A EC-2 Manual © 2002 Alesis. All rights reserved. Reproduction in whole or in part is prohibited. Specifications Subject To Change Without Notice. 7-51-0107-A 6/2002[...]

  • Page 3

    appendix A EC-2 Manual A-1 EC-2 96kHz Upgrade Cards This document covers only those aspects unique to the EC-2 cards and should be kept with the HD24 manual. Table of Contents Important Safety Instructions ................................ 2 Safety symbols used in this product ....................... 2 CE Declaration of Conformity ..................[...]

  • Page 4

    EC-2 96kHz A/D/D/A upgrade • appendix A A-2 EC-2 Manual Important Safety Instructions Safety symbols used in this product This symbol alerts the user that there are important operating and maintenance instructions in the literature accompanying this unit. This symbol warns the user of uninsulated voltage within the unit that can cause dangerous e[...]

  • Page 5

    appendix A • EC-2 96kHz A/D/D/A upgrade EC-2 Manual A-3 Installing the EC-2 into the HD24 Precautions The EC-2 boards should only be installed by a dealer or trained technician. End users should only attempt installation if they have experience with this type of procedure. If any of the following instructions are not clear to you, please have a d[...]

  • Page 6

    EC-2 96kHz A/D/D/A upgrade • appendix A A-4 EC-2 Manual Prepare to install: 1. Disconnect the HD24’s AC power cable, and make sure you are working on a clean, flat, hard surface. Ground yourself by touching a grounded metal object. An anti-static workstation with anti-static mat and wrist strap is highly recommended. Hazardous voltages are pres[...]

  • Page 7

    appendix A • EC-2 96kHz A/D/D/A upgrade EC-2 Manual A-5 Install the new EC-2 PCBs 7. Find the daughterboard in the EC-2 package: it has two 26-pin flexible cables attached to it. Insert the ribbon connector labeled “J4 TO MAIN PCB” on the daughterboard into the 26- pin header labeled on the main PCB as “J15 TO A/D PCB”. 8. Insert the ribb[...]

  • Page 8

    EC-2 96kHz A/D/D/A upgrade • appendix A A-6 EC-2 Manual Connect the PCBs 13. Connect the daughterboard to the Input and Output PCBs: Line up the connectors to the bottom (D/A) and top (A/D) PCBs, make sure all the pins line up, then gently push the daughterboard to the rear of the HD24 using the plastic ribbon cable headers as pressure points, ma[...]

  • Page 9

    appendix A • EC-2 96kHz A/D/D/A upgrade EC-2 Manual A-7 Synchronizing at high sample rates: To record more than 12 tracks in the high sample rate mode, simply synchronize two HD24/EC-2 units together by linking them with an ADAT Sync cable (see page 24 of the HD24 manual). Up to five HD24s may be synchronized this way, allowing high-sample rate s[...]

  • Page 10

    EC-2 96kHz A/D/D/A upgrade • appendix A A-8 EC-2 Manual About the EC-2’s audio performance An HD24 with the EC-2 upgrade has audio performance far superior to that of any analog recorder, and a wider dynamic range than most input and output devices that may be connected to it. Here’s why: The converter defines the sound The first and last ste[...]

  • Page 11

    appendix A • EC-2 96kHz A/D/D/A upgrade EC-2 Manual A-9 aliasing, the steeper the filter, the better. Some converters boasted 10 th -order (-60 dB per octave) filters. For comparison, most loudspeaker crossovers have 3 rd or 4 th -order filters (-18 or –24 dB per octave). The problem is similar on the output side—the 44.1 or 48 kHz sampling f[...]

  • Page 12

    EC-2 96kHz A/D/D/A upgrade • appendix A A-10 EC-2 Manual Extending the frequency range of other studio equipment Even though an ADAT HD24 equipped with the EC-2 upgrade gives you the capability of recording audio beyond 40 kHz, many other elements of your studio may need to be upgraded to truly take advantage of this capability. Most studio equip[...]

  • Page 13

    appendix A • EC-2 96kHz A/D/D/A upgrade EC-2 Manual A-11 Using the HD24/EC-2 with computer workstations and digital mixers Because the EC-2 upgrade provides 24 high quality inputs and outputs, it can be used as an external converter to extend the number of analog inputs and outputs of any computer workstations and digital mixers that feature an A[...]

  • Page 14

    EC-2 96kHz A/D/D/A upgrade • appendix A A-12 EC-2 Manual Using the HD24/EC-2 with the Alesis AI-4 AES/EBU Interface The Alesis AI-4 AES/EBU Digital Audio Interface is a single-rack space unit available from your Alesis dealer that lets you connect ADAT Optical input and output signals to industry-standard AES/EBU digital signals, eight channels a[...]

  • Page 15

    EC-2 Manual A-1 3 Specifications For the Alesis HD24 with EC-2 96 kHz Sample Rate Upgrade A/D and D/A Converter Boards: AUDIO INPUT Input Connectors: 24 balanced 1/4" TRS jacks Nominal Input Level: +4 dBu (1.23 V RMS ) = -15 dBFS Maximum Input Level: +19 dBu (6.9 V RMS ) = -0 dBFS Input impedance: 10 k Ω A/D converter: AKM 5393 Analog filter[...]