Allegro Industries 9832 manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Allegro Industries 9832, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Allegro Industries 9832 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Allegro Industries 9832. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Allegro Industries 9832 should contain:
- informations concerning technical data of Allegro Industries 9832
- name of the manufacturer and a year of construction of the Allegro Industries 9832 item
- rules of operation, control and maintenance of the Allegro Industries 9832 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Allegro Industries 9832 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Allegro Industries 9832, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Allegro Industries service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Allegro Industries 9832.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Allegro Industries 9832 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    USER'S MANUAL AMBIENT AIR BREATHING APPARATUS (AABA) PUMPS P/N 9806 P/N 9821 P/N 9832 P/N 9833 P/N 9846 P/N 9850 Read and understand all instructio ns before using this product. Open carton carefully and inspect pr oduct for damage caused by carrier. If any damage is found, report and submit claim to carrier. ALLEGRO ® INDUSTRIES P/N: UM006[...]

  • Page 2

    TABLE OF CONTENTS PAGE NUMBER INTRODUCTION/D ESCRIPTION ...................................................................................................... ............... 1 WARNINGS AND LI MIT ATIONS ....................................................................................................... ............... 1 SAFETY PREC AUTIONS ....[...]

  • Page 3

    INTRODUCTION This manual provides instructions for the u se and maintenance of Allegro Ambient Air Breathing Apparatus (AABA) Pumps. You must read and understand this manual and be trained in the proper use of the equipment before using it in a contam inated atmosphere . There are many federal, state, and l ocal codes and regulat ions governi ng sa[...]

  • Page 4

    S A F E T Y P R E C A U T I O N S FOLLOW ALL WARNIN GS AND CAUT IONS ALL PUMPS: DO NOT place oil-less air pum p in an area that cannot GU ARANTEE clean Gra de D breathable air, per OSHA 29 CFR 1910.134 to the AABA inlet. See below for Grade D requirements. DO NOT attempt to service the air pump while it is running or while it is connected to electr[...]

  • Page 5

    U S E R ’ S I N S T R U C T I O N S 1) Ensure that the pump (or inlet extension filter) is in a clean uncontamin ated air environment. o If clean air CANNOT be guaranteed at the pump inlet at all times, use the Inlet extension hose kit (P/N: 9700-65). See instructions on the Inlet extension k it below. 2) Ensure canister on the disch arge filter [...]

  • Page 6

    T O L E R A N C E S A N D W A R N I N G S Allegro ambient air pum ps are precision pum ps that have only .0015-.003 cl earance between the top o f the rotor a nd cylinder bore, and .003 or less cleara nce be tween end of the rotor a nd the end plate. Any thrust on th e shaft such as mishandling or drop ping the pump on its end will tend to close th[...]

  • Page 7

    S P E C I F I C A T I O N S The table shows the maximum allowable number of tight-fitting respirators or loose-fitting hood s. MODEL NUMBER PART NO. MAX NO. RESP. MAX NO. HOODS POWER REQUIRED LBS HP PSI CFM A-300 9806 1 0 5.5A 115/2 30V 30 ¼ 0 – 15 0 – 5 A-750 9821 2 1 8.3A 115/2 30V 53 ¾ 0 – 15 0 – 10 A-1500TE 9832 3 2 16A 115/23 0V 97 1[...]

  • Page 8

    M A I N T E N A N C E FILTERS: • Change inlet filter every 200 runn ing hours or if the pressure gauge shows a drop in pressur e. • Change discharge filter every 200 running hours or if the pressure gauge shows an increase in pressure. FLUSHING INSTRUCTIONS: 1. Perform this procedure in a well ventilated area. 2. Wear solvent resistant glo ves [...]

  • Page 9

    P A R T S & A C C E S S O R I E S All Models • 9700-02 Exhaust filter element (Each) • 9700-11 Pump flushing liqui d • 9700-15 Exhaust filter canister (Canister only) • 9700-65 Universal inlet hose kit (50 Feet) • 9700-68 ⅜ ” Coupler, locking Hansen • 9700-69 ⅜ ” Coupler, Hansen • 9700-71 ¼” Coupler, Schra der • 9700-[...]

  • Page 10

    T R O U B L E S H O O T I N G ELECTRIC MODELS: 1) If motor fails: • If motor is extrem ely cold. o Bring to room temperature before starting. • Ensure respirator and hose are connected when pump is running; failure to do so may cause lock-up. o Loosen all six pump end plate bolts sl ightly. R e-tighten a nd try t o run uni t. • Some motors ar[...]

  • Page 11

    4) If there is a drop in outlet pressure: • Check if exhaust filter housing and can ister is cross- t hreaded or not seated firmly onto housing gasket. o Remove canister, inspect t hreads and gasket and reinstall. • Check for dirty inlet filter element. o Replace if necessary. • Check if vanes are sticki ng or worn out. o Flush pump with appr[...]

  • Page 12

    WARRANTY Damage resulti ng from carri er handling abus e is not covere d by product war ranty. To protect your interest , inspect product im mediatel y. The foll owing warra nty inf ormation i s made in lieu of all other warranties expressed, implied or statutory, including but not li mited to, the implied warran ties of merchantability and fitness[...]

  • Page 13

    ambairpumman.doc Rev C. 07/03 11[...]