Go to page of
Similar user manuals
-
Switch
Allied Telesis 86222-27
46 pages 0.25 mb -
Network Router
Allied Telesis AT-MC103XL
28 pages 0.56 mb -
Switch
Allied Telesis Patch SB244-01
4 pages 0.28 mb -
Switch
Allied Telesis AT-FS717FC/SC
2 pages 0.05 mb -
Switch
Allied Telesis AT-GS950/24
44 pages 1.44 mb -
Switch
Allied Telesis AT-FH812U-SW
36 pages 1.54 mb -
Network Card
Allied Telesis AT-iBG915
2 pages 0.07 mb -
Network Card
Allied Telesis AT-2911LX/LC
120 pages 3.44 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Allied Telesis 6870, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Allied Telesis 6870 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Allied Telesis 6870. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Allied Telesis 6870 should contain:
- informations concerning technical data of Allied Telesis 6870
- name of the manufacturer and a year of construction of the Allied Telesis 6870 item
- rules of operation, control and maintenance of the Allied Telesis 6870 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Allied Telesis 6870 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Allied Telesis 6870, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Allied Telesis service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Allied Telesis 6870.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Allied Telesis 6870 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
15 Liberty St., Metuchen NJ 08840 1-800-LAB-SPEX (1-800-522-7739) ext 465 6870 FREEZER/MILL ® OPERATING MANUAL This manual is part number 85018[...]
-
Page 2
Page 2 of 25 SPEX SamplePrep LLC 9.24.07 TABLE OF CONTENTS SECTION DESCRIPTION PAGE 1.0 Introd uction .................................................................................................................................. 3 2.0 Specif icati ons ..............................................................................................[...]
-
Page 3
Page 3 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 1.0: INTRODUCTION SPEX SamplePrep Freezer/ Mills are cryogenic laboratory mills that cool samples to cryogenic temperatures, and pulverize them by m agnetically shuttling a steel impactor back and forth against two stationary end plugs. Since the vial is closed, the integrity o f its contents is main[...]
-
Page 4
Page 4 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 2.0: 6870 FREEZER/MILL SPECIFICATIONS Type of mill: cryogenic impact mill Grinding mechanism: steel im pactor driven by dual electromagnets Coolant: liquid nitrogen Weight (empty, without vial or coolant): a pprox. 44 lbs. (20 Kg) Grinding Vials: one 6801 Large Vial, one Mid-Size Vial (6871, 6881, 68[...]
-
Page 5
Page 5 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 3.0: UNPACKING Inspect the exterior of the packing box and repor t any visible damage to the carrier. Remove all packing documents from the exterior of the box, a nd save them for your records. Open the top of the shipping box. Remove the packing material and accessories, and gen tly remove the Freez[...]
-
Page 6
Page 6 of 25 SPEX SamplePrep LLC 9.24.07 6870 FREEZER/MILL, BACK VIEW SECTION 4: SETTING UP The 6870 Freezer/Mill weighs 44 pounds (20 Kg) empty. The lid opens fro m the front and the lid latch is in the center. The AC Input module is on the back of the cab inet, and includes the power switch and fuse tray. The fuse tray can be opened with small sc[...]
-
Page 7
Page 7 of 25 SPEX SamplePrep LLC 9.24.07 The control panel is a touch-screen, activated by a stylus. The Freezer/Mill is progra mmed and operated through this control panel, whose successive screens are described and illustrated in Section 5, starting on page 8. Programmable parame ters include pre-cooling time, grinding tim e, cooling time between[...]
-
Page 8
Page 8 of 25 SPEX SamplePrep LLC 9.24.07 4.4 Grinding Vial Sizes, Adapters, and Vial Openers. Large vials (6801, 6871) are run one at a time in the 6870 Freezer/Mill, w ithout any adapter. Large vials are opened by the 6804 Extractor/Vial Opener, which is p art of the 6870L Accessory Package. Mid-Size vials (6881, 6883, 6885) ar e run one at a time[...]
-
Page 9
Page 9 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 5.0: TOUCHSCREEN DISPLAYS The 6870 Freezer/Mill is programmed and operated through a series of touchscreen displays. Transition between screens, a nd all programming and operating commands, are done by touching the screen with a stylus. D o not use a sharp point as this can damage or deface the scree[...]
-
Page 10
Page 10 of 25 SPEX SamplePrep LLC 9.24.07 6) Third cycle: the coil is activated for the final 2-minute cycle. When it is done, the program is over and the sample has been ground for a total of 6 m inutes. 5.3 STATUS SCREEN To run the program displayed on the CURRENT SETTINGS screen, touch “Start SCRN.” This transfers you to the STATUS screen, w[...]
-
Page 11
Page 11 of 25 SPEX SamplePrep LLC 9.24.07 During the PRECOOL stage the TIME REMAINING line co unts down the time for that stage in 5-second increments: 4:45, 4:40, 4:35, etc. After the PRECOOL stage comes the first GRINDI NG stage, and the screen displays STATUS: GRINDING. The TIME REMAINING line will displa y the time left in that grinding stage. [...]
-
Page 12
Page 12 of 25 SPEX SamplePrep LLC 9.24.07 impactor strikes both ends of the vial, a rate of 10 represents 20 impacts per second. T he factory default setting for the rate is 10, and any saved program w ill revert to a rate of 10. To stop a program, touch STOP. The program will end. If RUN is pressed the entire program will start over. To pause duri[...]
-
Page 13
Page 13 of 25 SPEX SamplePrep LLC 9.24.07 To store the new program on the CURRENT SETTINGS screen, or to recall a stored program to override the new program, touch STO/RCL to take you to the first of two STORE/RECALL screens: 5.5 STORE/RECALL SCREENS Rcl Sto PRESET O: FISH SCALES Lbl Rcl Sto PRESET 1: Lbl Rcl Sto PRESET 2: Lbl Rcl Sto PRESET 3: Lbl[...]
-
Page 14
Page 14 of 25 SPEX SamplePrep LLC 9.24.07 As you touch the letter/number keys, what you ha ve entered appears above the keyboard in a mini-screen with a centered cursor. The SHIFT key lets you shift back and forth from upper case to lower case. Touching the SPACE key advances the cursor one space. Touching the BACK key sends th e cursor back one sp[...]
-
Page 15
Page 15 of 25 SPEX SamplePrep LLC 9.24.07 Note that there are three different sizes of vial that can be ru n in the 6870 Freeze r/Mill: Large, Mid-Size, and Small. Mid-Size vials must be run with a 6886 Adapter in the coil, and Sm all vials must be run with a 6806 Adapter in the coil. Large vials do not need an Adapter. See Section 4.4 for details.[...]
-
Page 16
Page 16 of 25 SPEX SamplePrep LLC 9.24.07 procedure for your own materials should be dete rm ined by trials; in practice almost no two materials grind alike. Avoid overfilling vials as this greatly reduces grinding efficiency. If at first the sample doesn’t gri nd as intended, try these strategies: • Reduce the overall weight of the sample. (So[...]
-
Page 17
Page 17 of 25 SPEX SamplePrep LLC 9.24.07 Accessory Packs can be placed in an insulated container to hold the v ials upright during chilling. At the same time, chill an im pactor separately. As soon as the submerged end of the vial is chilled, drop in the cold sam ple and then the chilled impactor. (Always wear insulated gloves when handling chille[...]
-
Page 18
Page 18 of 25 SPEX SamplePrep LLC 9.24.07 6.32 Opening the Vials To open a vial, slip the open end of the appropr iate Extracto r/Vial Opener over a threaded end- plug, align the pegs in the end-plug with the sl ots in the Extractor, and turn the knob clockwise until the end-plug is drawn out. If the end-plug is drawn out within a m illimeter or tw[...]
-
Page 19
Page 19 of 25 SPEX SamplePrep LLC 9.24.07 The impactor will have to be separated from the sample and can be handled with gloved fingers, a strong magnet, tongs, or pliers. Tools without a good gripping surface are li kely to slip off the impactor. If some condensation on a cold sam ple is unaccept able, you can either wait for the sample vial to wa[...]
-
Page 20
Page 20 of 25 SPEX SamplePrep LLC 9.24.07 6.4 Checking The Liquid Nitrogen Level Every time you remove or insert a vial, note the le vel of liquid nitrogen (LN) in the tub. You should top off the LN when needed as a matter of routine. If your programmed grinding cycle includes more than twenty or th irty minutes of actual grinding time, you should [...]
-
Page 21
Page 21 of 25 SPEX SamplePrep LLC 9.24.07 Operation : when the 6870 Freezer/Mill is set up for the firs t run of the day, with a loaded vial in the coil, make sure the LN valve on the supply tank or line is open. Go to the STATUS screen and touch RUN. The Auto-Fill valve will open and let LN into the Free zer/Mill tub. The valve may close and open [...]
-
Page 22
Page 22 of 25 SPEX SamplePrep LLC 9.24.07 temperature before attempting to clean it. Once the unit has attained room tem perature, wipe down the unit as indicated previously. Af ter every period of use, the m ill is going to be wet with condensation since the Freezer/Mill will pi ck up moisture as long as it is cold. To maintain the exterior of the[...]
-
Page 23
Page 23 of 25 SPEX SamplePrep LLC 9.24.07 7.04 Contacting SPEX SamplePrep LLC Within the United States, write, telephone, or e-mail us at: SPEX SamplePrep LLC 15 Liberty St. Metuchen, New Jersey 08840 Tel.: 732-549-7144 or 800-522-7739 Fax: 732-906-2492 Website: www.spexcsp.com E-mail: sampleprep@spexcsp.com Outside the United States, contact the S[...]
-
Page 24
Page 24 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 8.0: TROUBLE-SHOOTIN G GUIDE, PAGE 1 OF 2 PROBLEM CAUSE SOLUTION 1 The unit does not turn on No power Ma ke sure power cord is plugged into outlet and inlet 2 The unit does not turn on No power Check outlet for power and correct as required 3 The unit does not turn on Power switch not turned on Swit[...]
-
Page 25
Page 25 of 25 SPEX SamplePrep LLC 9.24.07 SECTION 9.0: TROUBLE-SHOOTIN G GUIDE, PAGE 2 OF 2 PROBLEM CAUSE SOLUTION 14 Blunt end-plug doesn’t come off room-temperature vial Hard to grip Warm vial under hot water. Use wide-jaw pliers if necessary. 15 Extractor jams Water on extractor screws or bell Dry extractor before each use 16 Extractor jams Ic[...]