Allied Telesis AT-GS24 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Allied Telesis AT-GS24, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Allied Telesis AT-GS24 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Allied Telesis AT-GS24. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Allied Telesis AT-GS24 should contain:
- informations concerning technical data of Allied Telesis AT-GS24
- name of the manufacturer and a year of construction of the Allied Telesis AT-GS24 item
- rules of operation, control and maintenance of the Allied Telesis AT-GS24 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Allied Telesis AT-GS24 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Allied Telesis AT-GS24, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Allied Telesis service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Allied Telesis AT-GS24.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Allied Telesis AT-GS24 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    613-001499 Rev B AT-GS950/24 Gigabit Ethernet Smar t Switch How to Start a WEB Management Session[...]

  • Page 2

    Copyright © 2011 Allied Telesis, Inc. All rights reserved. No part of this pub lication may be reproduced without prior wri tten permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, lo gos or other designations mentioned herei n are t[...]

  • Page 3

    3 How to S tart an A T -GS950/24 WEB Management Session This document contains the procedu res to start you Web management session on the AT-GS950/24 switch. The followin g topics are discussed:  “Establishing a Remo te Connection to the W eb Browser Interface” on page 4  “Web Browse r T ools” on page 8  “Configuration of IP Addr[...]

  • Page 4

    How to Start an AT-GS950/24 WEB Management Session 4 Establishing a Remote Connectio n to the Web Brow ser Interface The AT-GS950/24 switch is shipped with a pre-assigned IP a ddress of 192.168.1.1. After your initial login, you may want to assign a n ew IP address to your switch. To manually assign an IP address to the switch, refer to “Configur[...]

  • Page 5

    How to Start an AT-GS950/2 4 WEB Management Session 5 The A T -S109 Management Sof tware displays the login dialog box, shown in Figure 2. Figure 2. Management Login Dialo g Box 3. Enter the AT-S109 management login u ser name and password. The default user name is “manager” and the defa ult password is “friend.” 4. Press OK. The login name[...]

  • Page 6

    How to Start an AT-GS950/24 WEB Management Session 6 Figure 3. AT-S109 Home Pag e The main menu appears on the left side an d is common for all of the management pages discussed in this manual. It consists of the following folders and web pages:  Switch Info.  Front Panel  System  Physical Interface  Bridge  SNMP  Access Contro[...]

  • Page 7

    How to Start an AT-GS950/2 4 WEB Management Session 7 5. To see the front panel of the switch, select Front Panel from the main menu on the left side of the page. The A T -S109 Management sof tware displays the front of th e switch. Ports that have a link to an end node are green. Port s without a link are grey . The A T -GS950/24 switch front pan [...]

  • Page 8

    How to Start an AT-GS950/24 WEB Management Session 8 Web Browser Tools You can use the web browser tools to move around the management pages. Selecting Back on your browse r’s toolbar returns you to the previous display. You can also use the browser’s bookmark featu re to save the link to the switch.[...]

  • Page 9

    How to Start an AT-GS950/2 4 WEB Management Session 9 Configuration of IP Address, Subnet Mask and Gateway Address This procedure explains how to chang e the IP address, subnet ma sk, and gateway address of the switch. Before performing the procedure, note the following:  A gateway address is only required if you want to remote ly manage the dev[...]

  • Page 10

    How to Start an AT-GS950/24 WEB Management Session 10 System Default Gatewa y - Displays the default gateway of the switch. To change the default gatewa y, enter a new gateway. When DHCP is enabled, you cannot change this parameter. DHCP Mode - For information about setting this parameter, refer to “DHCP Client Configuration” on page 18. 4. Cli[...]

  • Page 11

    How to Start an AT-GS950/2 4 WEB Management Session 11 IP Access List Configuration When the IP Access List feature is enabled, remote access to the AT-S109 management software is restricted to the IP addresses entered into the IP Access List. The procedures in this section describ e how to e nable or disable the IP Access List feature and how to a[...]

  • Page 12

    How to Start an AT-GS950/24 WEB Management Session 12 Note You can add up to 10 IP addre ss to the IP Access List table.[...]

  • Page 13

    How to Start an AT-GS950/2 4 WEB Management Session 13 5. From the IP Restriction Status field, select one of the following choices from the pull-down menu: Enable - This selection restricts the access to the AT-S109 management software to the IP addresses in the table listed under Accessible IP . Disable - This selection allows unrestricted access[...]

  • Page 14

    How to Start an AT-GS950/24 WEB Management Session 14 System Time The procedures in this section describe how to configure the system time by manually entering the time or through SNTP an d how to configure the daylight savings time feature. See the fo llowing sections:  “Manually Setting System T ime” on page 14  “Setting SNTP” on p [...]

  • Page 15

    How to Start an AT-GS950/2 4 WEB Management Session 15 3. Use the pull down menu to set the Clock Mode parameter to Local time. 4. In the Local Time Settings section, set the Date Setting (YYYY:MM:DD) to the current date in the YYYY:MM:DD format. 5. In the Local Time Settings section, set the Time Settings (HH:MM:SS) to the current time in the HH:M[...]

  • Page 16

    How to Start an AT-GS950/24 WEB Management Session 16 Setting Daylight Savings Parameters If you want to configure the switch f or daylight savings time, perform the following procedure: 1. From the main menu on the left side of the page, click the System folder. The System folder expands. 2. From the System folder, select System Time. The System T[...]

  • Page 17

    How to Start an AT-GS950/2 4 WEB Management Session 17 DHCP and ATI Web Discovery Tool The AT-GS950/24 Gigabit Ethernet Smart swit ch is managed through a web browser interface only. The factory default IP ad dress is 192.168.1.1. The switch does not have a local co nsole connector, which means that you cannot learn what the switch’s manageme nt [...]

  • Page 18

    How to Start an AT-GS950/24 WEB Management Session 18 DHCP Client Configuration This procedure explains how to activate and deactivate the DHCP client on the AT-GS950/24 switch. When the clien t is activated, the switch obtains its IP configuration including an IP address an d subnet mask from a DHCP server on your network. Before perfo rming the p[...]

  • Page 19

    How to Start an AT-GS950/2 4 WEB Management Session 19 Note The ATI Web Discovery Tool is available for downlo ad on the AT-GS950/24 product page at alliedtelesis.com . 6. Follow the procedure to log on with the new IP ad dress provided by the DHCP Server as described in “Est ablish ing a Remote Connection to the Web Browser Interface” on p age[...]

  • Page 20

    How to Start an AT-GS950/24 WEB Management Session 20 DHCP Auto Configuration If you need to automatically update the switch’s configuration files via a remote server, the DHCP Auto Co nfiguration feature is ava ilable for this purpose via the DHCP server. Note You must enable the DHCP client so that this feature can operate with the DHCP server.[...]

  • Page 21

    How to Start an AT-GS950/2 4 WEB Management Session 21 System Management Information This section explains how to assi gn a name , location, and contact information for the AT- GS950/24 switch. This information helps in identifying each specific AT-GS9 50/24 switch among other switches in the same local area network. Entering this information is op[...]

  • Page 22

    How to Start an AT-GS950/24 WEB Management Session 22 System Name - Specifies a n ame for the switch, for example, Sales. The name is option al and may contain up to 15 characters. System Location - Sp ecifies the location of the switch. The location is optional and may contain up t o 30 characters. System Contact - Specifies the name of the networ[...]

  • Page 23

    How to Start an AT-GS950/2 4 WEB Management Session 23 User Name and Password Configuration Password protection is always enabled for access to th e AT-S109 Management software. This sectio n explains how to create new users names and passwords and how to mod ify or delete existing users for the web interface. See the following sections:  “Add[...]

  • Page 24

    How to Start an AT-GS950/24 WEB Management Session 24 4. To add a password that corresponds to the use r name entered in step 3, enter a password of up to 12 a lphanumeric characters in the box next to the Password field. The P asswor d field is case sensitive. 5. To confirm the password entry, retype the password in the box ne xt to the Confirm Pa[...]

  • Page 25

    How to Start an AT-GS950/2 4 WEB Management Session 25 Delete User Name and Password To delete a user name that you hav e previously added, perform the following procedure. 1. From the main menu on the left side of t he page, click the System folder. The System folder expands. 2. From the System folder, select Administration . The Administration Pa[...]

  • Page 26

    How to Start an AT-GS950/24 WEB Management Session 26 User Interface Configuration This procedure explains how to enable and disable the user interfaces on the switch. With this procedure you can enable or disable the AT-GS950/ 24 SNMP Agent. For more information about SNMP, see the AT-GS950 Web User Guide. The Web Server Status is displayed as En [...]

  • Page 27

    How to Start an AT-GS950/2 4 WEB Management Session 27 5. From the main menu on the left side of t he page, select Save Configuration to Flash to perman ently save your changes. User Interface Timeout To set the Web Idle Time out, perform the following procedure: 1. From the main menu on the left side of t he page, click the System folder. The Syst[...]

  • Page 28

    How to Start an AT-GS950/24 WEB Management Session 28 System Information Display The Switch Information page is initially displayed when you first log into the AT-GS950/24 switch. It provides general information about the switch. To view this information, perform the follo wing procedure: 1. From the main menu on the left side of the page, select S[...]

  • Page 29

    How to Start an AT-GS950/2 4 WEB Management Session 29 Administration Information Section: Switch Name - This paramet er displays the name assigned to the switch. To assign the switch a name, refer to “System Management Information” on page 21. Switch Location - This p arameter displays the location of the switch. To assign the location, refer [...]

  • Page 30

    How to Start an AT-GS950/24 WEB Management Session 30 Switch Reboot You can reboot the AT-GS950/24 switch b y either pressing the front panel eco-friendly switch between 5 to 9 seconds or by using the Normal reboot function provided in the AT-S109 management software. In addition to rebooting the switch, yo u have the option to reset the AT-GS950/2[...]

  • Page 31

    How to Start an AT-GS950/2 4 WEB Management Session 31 Caution Since you define this password as part of the process o f disabling this function, Allied Telesis has no knowledge of it. You ar e responsible for keeping the password in a safe place. If it is lost, Allied Telesis does not have a way to help you recover it. See “Disabling Factory Def[...]

  • Page 32

    How to Start an AT-GS950/24 WEB Management Session 32 Figure 14. Factory Default Reset/Reboot Page 3. Go to the lower part of the page to the Reb oot section. 4. In the Reboot Type field, select Normal from the pull-down menu. When the switch is rebooted with this selection, all co nfiguration parameters that are saved in flash memory are loaded in[...]

  • Page 33

    How to Start an AT-GS950/2 4 WEB Management Session 33 Caution This procedure causes the switch to re boot. The switch does not forward network traffic during th e reboot process. Some network traffic may be lost. To return the AT-S109 Management so ftware to the default settings, perform the following procedure: Note The AT-S109 Management softwar[...]

  • Page 34

    How to Start an AT-GS950/24 WEB Management Session 34 5. Click Apply . The switch begins the reboot process. You must wa it approximately two minutes for the switch to complete the re boot process before you can re-establish your management session and network traffic begins flowing normally again. Disabling Factory Default Reset Feature The factor[...]

  • Page 35

    How to Start an AT-GS950/2 4 WEB Management Session 35 Figure 15. Factory Default Reset/Reboot Page with Password Entry 5. In the New Password field, enter a passwo rd of up to 12 characters in length. It is case-sensitive. There is not a default password for this field. Caution Since you define this password as part of the process o f disabling th[...]

  • Page 36

    How to Start an AT-GS950/24 WEB Management Session 36 Enabling Factory Default Reset If the Factory Default Reset featu re is disabled and you choose to Enable it, perform the following procedure: 1. From the main menu on the left side of the page, select the Tools folder. The Tools folder expands. 2. From the Tools folder, select Reboot . The Fact[...]

  • Page 37

    How to Start an AT-GS950/2 4 WEB Management Session 37 Pinging a Remote System This procedure instructs the AT-GS9 50/24 switch to ping a node on your network. This pr ocedure is useful in determining whether a n active link exists between the switch and anoth er network device. Note The device you are pinging must be a member of the Default VLAN a[...]

  • Page 38

    How to Start an AT-GS950/24 WEB Management Session 38 5. To view the ping results, click Show Ping Re sults . A sample Ping Test Results Page is displayed. See Figure 19. Figure 19. Ping Test Results Page The following information is displayed: Destination IP Address - Indicates the IP address of the unit that receives the ping. Pass - Indicates th[...]

  • Page 39

    How to Start an AT-GS950/2 4 WEB Management Session 39 SSL Settings The AT-GS950/24 switch has a web bro wser server for remote management of the unit with a web browser application from managemen t workstations on your network. By default, the server operates in a non-secure HTTP mode and can be c onfigured to co mmunicate in a secure HTTPS mode w[...]

  • Page 40

    How to Start an AT-GS950/24 WEB Management Session 40 4. Click Apply . The SSL setting that you have selected is now active. 5. From the main menu on the left side of the page, select Save Configuration to Flash to permanent ly save your changes.[...]

  • Page 41

    How to Start an AT-GS950/2 4 WEB Management Session 41 System Log Configuration The System log is designed to monitor the operation the AT-GS950/24 switch by recording the event messa ges it generates during normal operation. These events may provide vital informa tion about system activity that can help in the id entification and solutions of syst[...]

  • Page 42

    How to Start an AT-GS950/24 WEB Management Session 42 3. From the Syslog Status field, select o ne of the follo wing choices from the pull-down men u: Enable - The System log is active. Disable - The System log is inactive. 4. From the Time Stamp field, select one of the following choices from the pull-down men u: Enable - Each even t message recor[...]

  • Page 43

    How to Start an AT-GS950/2 4 WEB Management Session 43 Returning the AT-S109 Management Software to the Factory Default Values This procedure returns all AT-S109 Man agement software parameters to their default values and deletes all tagge d and port-based VLANs on the switch. This procedure causes the switch to re boot. The switch does not forward[...]

  • Page 44

    How to Start an AT-GS950/24 WEB Management Session 44 Quitting a Web Browser Management Session To exit a web browser management session, clo se the web browser.[...]