Altinex MX2216RM manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Altinex MX2216RM, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Altinex MX2216RM one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Altinex MX2216RM. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Altinex MX2216RM should contain:
- informations concerning technical data of Altinex MX2216RM
- name of the manufacturer and a year of construction of the Altinex MX2216RM item
- rules of operation, control and maintenance of the Altinex MX2216RM item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Altinex MX2216RM alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Altinex MX2216RM, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Altinex service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Altinex MX2216RM.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Altinex MX2216RM item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SWITCHERS MANUAL PART NUMBER: 400-0064-002 PRODUCT REVISION: 2 MX2216RM 6 - IN, 1 - OUT RGBS SWITCHER USER’S GUIDE[...]

  • Page 2

    SWITCHERS 1 INTRODUCTION Thank you for purchasing the MX2216RM Switcher. We are sure you will find it a reliable and useful product. Superior performance for the right price backed by solid technical and customer support is what we have to offer. The product you are holding in your hands is designed using state-of-the-art technology and is superior[...]

  • Page 3

    SWITCHERS 2 PRECAUTIONS / SAFETY WARNINGS 1 Please read this manual carefully before using your MX2216RM Switcher. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MX2216RM and to prevent fire and shock hazard. Please read them carefully and heed all warnings. 1.1 GENERAL • Unauthorized pe[...]

  • Page 4

    SWITCHERS 3 cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. • Any changes or modifications to the unit not expressly approved by Altinex, Inc. could void the user’s[...]

  • Page 5

    SWITCHERS 4 Output Sync Signal Composite Sync TTL(+/-), Analog 0.3-1.0V Sync on Green -0.3V Impedance pass-through Frequency Compatibility Horizontal 15-200 kHz Vertical 30-190 Hz Typical Video Bandwidth 400 MHz Cross-talk -48dB @ 10 MHz Coupling DC Power External Power Adapter 90-140V/200-240V (selectable) Power Consumption 10 watts max. Table 3. [...]

  • Page 6

    SWITCHERS 5 The front panel of the MX2216RM provides access to essentially all of the switcher’s capabilities. In addition to standard switching functions, the unit has control and switching functions that could be very useful in a variety of special applications. 4.1 SELECT INPUT When buttons 1 through 6 are pressed, the corresponding INPUT will[...]

  • Page 7

    SWITCHERS 6 In addition to forward connection, the MX2216RM can be connected in a reverse direction. In this configuration one video source is selectively sent to each of the video monitors. This capability is referred to as bi-directional switching. In this configuration only one display device can be operational at any given time. APPLICATION DIA[...]

  • Page 8

    SWITCHERS 7 OPERATION 7 7.1 RS-232 CONTROL The MX2216RM Switcher uses a female 9-pin HD connector on its rear panel that allows access to a variety of control capabilities. PIN No. PIN Designation 1 No connection 2 RS-232 Transmit 3 RS-232 Receive 4 No connection 5 Ground 6 Multiple Switcher Loop Control 7 Analog Switch Voltage Input 8 +5 V (150 mA[...]

  • Page 9

    SWITCHERS 8 The MX2216RM Switcher is also designed to send feedback commands from the switcher to the control system when the buttons on the front panel of the switcher are pressed. The Feedback codes are as follows: Key pressed Description Feedback Code 1 Input Select [INP1] 2 Input Select [INP2] 3 Input Select [INP3] 4 Input Select [INP4] 5 Input[...]

  • Page 10

    SWITCHERS 9 With this configuration, the master unit has ultimate control over the slave unit. 7.4 CONTACT CLOSURE (ONE WIRE ANALOG) CONTROL The one-wire control is an alternative to a multi- wire contact closure control. This control pin allows you to select different channels based on the DC voltage level on pin 7 of the 9 pin D connector. Intern[...]

  • Page 11

    SWITCHERS 10 The loop control pin has an internal 100k resistor to +5volts. This limits the number of switchers looped to a maximum of 10 switchers that are daisy chained together using this method. More specifically, the output of one switcher is connected to INPUT 6 of the next switcher. Once loop control is enabled, these switchers will automati[...]

  • Page 12

    SWITCHERS 11 ACCESSORIES 8 Model No. Description TABLE MOUNT HARDWARE TM1276 Table Mount bracket for 2U ½ Rack- Wide RACK MOUNTING ACCESSORIES DA1298RM Rack mount shelf for two units side by side DA1299RM Rack mount kit for single unit. CONTROL CABLES RC5204CC Analog to contact Closure Adapter 6 ft RC5207CC RS-232/Master-Slave Control cable HIGH R[...]

  • Page 13

    SWITCHERS 12 Switcher be used outside of the United States? supply, enabling it to be used throughout the world. Please make sure to have the voltage setting in the correct position and please make sure to use the proper adapter cable for the country where it will be used. Adapter cables for several countries are available through Altinex. 7 How do[...]

  • Page 14

    SWITCHERS 13 ALTINEX POLICY 11 11.1 LIMITED WARRANTY Altinex warrants that its products and cables are free from defects in materials under normal use and service. This warranty is limited to repairing at company’s factory any part or parts of the product, which upon company’s examination shall disclose to be, thus defective. Products considere[...]