A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Amana PGC(24-60)B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Amana PGC(24-60)B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Amana PGC(24-60)B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Amana PGC(24-60)B should contain:
- informations concerning technical data of Amana PGC(24-60)B
- name of the manufacturer and a year of construction of the Amana PGC(24-60)B item
- rules of operation, control and maintenance of the Amana PGC(24-60)B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Amana PGC(24-60)B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Amana PGC(24-60)B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Amana service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Amana PGC(24-60)B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Amana PGC(24-60)B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Gas-Electric Package Unit Cooling and Heating Installation Instructions MODELS PGC(24-60)B and PGB58B May 1998 (2) 11073904 Amana Fayetteville, TN 37334 As a professional installer you have an obligation to know the product better than the customer. This in- cludes all safety precautions and related items. Prior to actual installation, thoroughly f[...]
-
Page 2
2 I. Unit Specifications MO DEL PGC24 B0452A P GC24B07 02A P GC30B07 02A PGC36 B0702A PGC36 B0902A Cool in g Ca paci ty Btuh 24,00 0 24,00 0 30,000 36,00 0 36,000 SEE R 12.50 12. 50 12. 30 12.00 12.00 Heati ng I nput B tuh 45,00 0 70,000 70,000 70,000 90,000 Output Btuh 35,00 0 55,000 55,000 55,000 70,000 A FUE 80.9 80. 1 80.1 80.1 80. 4 Temperat u[...]
-
Page 3
3 Table 1B Gas Pack Specifications 1) United States Installation 2) Specification subject to change without notice. See sales specification sheets for certain BTUH capacities. 3) This PGC series complies with requirements embodied in the American National Standard ANSI-Z21.47 Central Furnaces. 4) Filters are not supplied with units, but filters mus[...]
-
Page 4
4 Table 1C Gas Pack Specifications M ODEL PGB58B 0902A PGB58B1152A PGB58B 1352A Cooling Capacity Btuh 59,500 59,500 59,500 SEER 11.10 11.10 11.10 Heating Input Btuh 90,000 115,000 135,000 Output Bt uh 72,000 92,000 108,000 AFUE 81.4 79.9 80.5 T emperatur e Ri se °F 25- 55 25-55 25-55 Num b er o f Bu rn e rs 4 4 4 Compres sor R.L. Amps 28.8 28.8 28[...]
-
Page 5
5 1. Installation is to be adjusted to obtain temperature rise within the range specified on the rating plate. 2. The temperature rise is for units installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise and CFM. 3. The chart is applicable for both vertical and horizontal airflow. 4. [...]
-
Page 6
6 II. Safety Information Important To The Installer Before installing this unit please read this manual to fa- miliarize yourself with the specific items which must be adhered to such as maximum external static pressure to unit, air temperature rise, minimum or maximum CF M and motor speed connections. Affix these Installation Instructions adjacent[...]
-
Page 7
7 Locating The Unit WARNING To avoid possible equipment damage, fire, personal injury, or death, the follow- ing points must be observed when install- ing the unit. All Installations: • For proper flame pattern within the heat exchanger and proper condensate drainage, the unit must be mounted level. • The unit should be as centralized as is pra[...]
-
Page 8
8 Figure 1 Required Clearances For All Installations[...]
-
Page 9
9 Transportation Damage All units are securely packed in shipping cartons ap- proved by the International Safe Transit Association. The carton should be checked upon arrival for external dam- age. If damage is found, a request for inspection by car- rier agent should be made in writing immediately. The unit should be carefully inspected upon arriva[...]
-
Page 10
10 V . Gas Piping IMPORTANT NOTE: This furnace is factory set to oper- ate on natural gas at the altitudes shown on the rating plate. If operation at higher altitudes and/or propane gas operation is required, obtain and install the proper con- version kit(s) before operating this furnace. Failure to do so may result in unsatisfactory operation and/[...]
-
Page 11
11 Figure 3 Proper Piping Practice Checking The Gas Piping CAUTION To avoid the possibility of personal in- jury, property damage or fire, the follow- ing instructions must be performed re- garding gas connections and pressure testing: • This unit and its gas connections must be leak tested before placing in opera- tion. Because of the danger of [...]
-
Page 12
12 Special pipe dope must be used when assembling pip- ing for this gas as it will quickly dissolve white lead or most standard commercial compounds. Shellac base compounds resistant to the actions of liquefied petro- leum gases such as Gasolac, Static, Clyde or John Crane are satisfactory. Please refer to Figure 4 for typical propane gas instal- l[...]
-
Page 13
13 CAUTION To prevent improper and dangerous op- eration due to wiring errors, label all wires prior to disconnection when servicing controls. Verify proper operation after servicing. Vll. Circulating Air and Filters Airflow Conversion Units can easily be converted from horizontal to vertical airflow delivery. Units will ship from the factory ready[...]
-
Page 14
14 Figure 8 Typical Electrical Wiring Typical Wiring (Ground Level) Disconnect Swit ch High V ol tag e So urc e High Volt age Ent rance Low Vol ta ge Ent rance Typical Wiring (Rooftop ) Disconnect Swit ch High V ol tag e So urc e High Volt age Ent rance Low Vol ta ge Ent rance Junctio n Box Roofto p Curb[...]
-
Page 15
15 Duct systems and register sizes must be properly de- signed for the C.F.M. and external static pressure rating of the unit. Ductwork should be designed in accordance with the recommended methods of Air Conditioning Con- tractors of America Manual D (Residential) or Manual Q (Commercial). All ductwork exposed to the outdoors must include a weathe[...]
-
Page 16
16 VIII. Flue V ent Flue Hood And Air Inlet Hood Installation The flue hood and air inlet hood are packaged in a box which is located inside the return air compartment. They must be installed prior to operation of the unit. See Fig- ure 10. To install the flue hood cover: 1. Remove the flue hood from inside the box. 2. Slide the upper lip of the ho[...]
-
Page 17
17 Air Ci rcu lat i on B l ower Gas Val v e Ignitor Pressure S wit ch (N.O . Co ntacts) Comb ust i on Bl o wer Therm ostat ON OFF ON OFF ON OFF ON OFF OPEN CLO S E D CLO S E D OPEN S e co n d s 0 34 3 8 11 0 0 9 0 Therm ostat ON Gas Val v e Open s Ignitor O FF Air Bl ower ON Therm ostat OFF Comb us t i on Pro duc t Purg e E nds . Air Bl ower OFF Co[...]
-
Page 18
18 X. Heating Sequence of Operations PGB & PGC) Normal Sequence of Operation - Heating See Figure 12 1. Thermostat calls for heat. The combustion blower is immediately energized. 2. The pressure switch contacts transfer. 3. The ignitor is energized and allowed to preheat for 38 seconds. 4. The gas valve is energized delivering gas to the burner[...]
-
Page 19
19 WARNING To avoid the risk of fire or explosion, a qualified servicer must investigate the problem which caused the roll-out pro- tection device to open before manually resetting the device. Flam e R oll-Out Protect o r (M an ua l Re s et) Figure 14 Rollout Protection (Shown Without Heat Shield) Secondary Limit Control On the PGC and PGB series, [...]
-
Page 20
20 Gas Input And Pressures Gas supply pressure and manifold pressure with the burners operating must be as specified on the rating plate. Checking Gas Pressure Gas inlet pressure should be checked and adjusted in accordance to the type of fuel being consumed. With Power And Gas Off: 1. Connect a water manometer or adequate gauge to the manifold gas[...]
-
Page 21
21 With a properly designed system, the proper amount of temperature rise will normally be obtained when the unit is operated at rated input with the recommended blower speed. If the correct amount of temperature rise is not obtained, it may be necessary to change the blower speed. A higher blower speed will lower the temperature rise. A slower blo[...]
-
Page 22
22 Figure 18 Fan and Limit Control CAUTION This unit should not be used as a “con- struction heater” during the finishing phases of construction on a new struc- ture. This type of use may result in pre- mature failure of the unit due to extremely low return air temperatures and exposure to very dirty atmospheres. To Turn Off Unit 1. Set the the[...]
-
Page 23
23 Important Note: Never close the compressor suction line to test its pumping efficiency. This will seriously dam- age the compressor and void its warranty. • The compressor may run backwards (noisy opera- tion) for 1 or 2 seconds at shutdown. This does not harm the compressor. • These scroll compressors have copper plated steel suction tubes.[...]
-
Page 24
24 When installing a new filter or reinstalling an old one, always make certain the air flow arrows on the filter point in the proper direction. If using the unit filter rack, the airflow arrows must point toward the indoor blower. To inspect the filter in the filter rack, proceed as follows: 1. Disconnect power to the unit. 2. Locate the filter ac[...]
-
Page 25
25 Flame Sensor (Qualified Servicer Only) Under some conditions, the fuel or combustion air sup- ply can create a nearly invisible coating on the flame sensor. This coating acts as an insulator causing a drop in the flame sensing signal. If this occurs, a qualified servicer should carefully clean the flame sensor with emery cloth or steel wool. Aft[...]
-
Page 26
26 Burners WARNING To avoid personal injury or death due to electrical shock, do not remove any internal compartment covers or attempt any adjustment. Contact a qualified ser- vicer at once if an abnormal flame ap- pearance should develop. At least once a year, prior to or during the heating sea- son, make a visual check of the burner flames. NOTE:[...]
-
Page 27
27 XV . T ypical Cooling Performance Data O utdoor In door PGC24 PG C30 PGC36 Air Te m p . at Air Te m p. In door Air Te m p . P res su re @ U n i t G auge F i tti ngs Am ps Indo or Air Te m p . P res su re @ U n i t G auge F i tti ngs Am ps Indo or Air Te m p . P res su re @ U n i t G auge F i tti ngs Am ps C o n den ser Inle t (D ry B ulb) at E v[...]
-
Page 28
28 Outdoor Indoor PGC42 P GC48 P GC60 a nd P GB58 Air T em p. at Air Tem p. Indoor Air T em p. Pres sure @ Uni t Gau ge Fi tt in gs Amps Indoor Air T em p. P ressure @ U nit Gau ge Fi tt in gs Amps Indoor Air T em p. P ressure @ U nit Gau ge Fi tt in gs Amps Condenser Inlet (D ry Bu lb) at E va p. Inlet (Wet Bulb) Diff er ence Bet ween Coil Inle t [...]
-
Page 29
29 XVI. Wiring Diagram PGC24 - 36[...]
-
Page 30
30 PGC 42[...]
-
Page 31
31 PGC 48[...]
-
Page 32
32 PGC 60 YL YEL LOW OR ORANGE VT V IOLET GN GREEN BK BL ACK BR BROW N WH WHITE BU BLUE GY GRAY RD RED COLOR COD E LOW VOLTAGE LOW VOLTAGE FIELD HI VOLT A GE HI VO LT AGE FI ELD * HEAT TA P MODE L NO . PGC60B0902A FACTOR Y WI RE D MOTOR CO NN ECTI O NS 11160801 REV. 0 ** COOL TA P RE AD B EFOR E OPER ATIN G OR SER VIC ING T HIS UNIT . W AR NIN G: D[...]
-
Page 33
33 PGB 58 YL YEL L OW OR O RAN GE VT VIO L ET GN GR EEN BK BLAC K BR BR OWN WH WHITE BU BLU E GY G R AY RD RED CO LOR C OD E LOW VO LTAGE LOW VO LTAGE FIEL D HI VOL TAGE HI VOL TAGE FIELD * HE ATI NG B LOW ER SP E ED MO DE L NO . PG B5 8B 09 0 PG B5 8B 11 5 FACTORY WIR ED MOTO R CONNEC TIONS 11 16 10 0 1 R EV . 0 SPEE D LO W MED ** COO L I NG BL O [...]