Amcor 9KE-410 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Amcor 9KE-410, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Amcor 9KE-410 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Amcor 9KE-410. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Amcor 9KE-410 should contain:
- informations concerning technical data of Amcor 9KE-410
- name of the manufacturer and a year of construction of the Amcor 9KE-410 item
- rules of operation, control and maintenance of the Amcor 9KE-410 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Amcor 9KE-410 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Amcor 9KE-410, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Amcor service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Amcor 9KE-410.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Amcor 9KE-410 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    PORT ABLE AIR CONDITIONER PMMBI 9KE-410 12KE-410 15KE-410 GB Portable air conditioner with ionizer[...]

  • Page 2

    2 GB SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer . Before you use your new air conditioner you should carefully read these instructions to maximise[...]

  • Page 3

    3 GB • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer , its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed by an authorized s[...]

  • Page 4

    4 GB Slide bar connector Active carbon filter T elescopic slide bar Exhaust hose W ater container Remote control with LCD PA R T S[...]

  • Page 5

    5 GB CON TROL P ANEL ON / OFF Swing Increase Decrease Mode Ionizer Fa n Sleep mode Timer Clock/ C ooling F an Timer T emperature Timer Ionizer settings[...]

  • Page 6

    6 GB INS T A LL A TI ON WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another . In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles. – T o place the loose filters[...]

  • Page 7

    7 GB ON/OFF Press to switch the unit on or to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash. Press or to adjust the hour . Press momentarily , the 2 right digits of the 4 digits w[...]

  • Page 8

    8 GB Programming the timer for ON - when the unit is OFF. • Perform the standard steps as described above. The linear time scale will be on between the ON programmed times until 24:00. The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the ON timer time, then the black segments i[...]

  • Page 9

    9 GB Air flow On the moment the air conditioner is connected to the mains, the louvres open and close and stay closed. • When the ON-button is pressed, the louvres open to maximum and return to an angle of 75° above the upper plane of the louvres housing. • Press the -button, the louvres will swing continuously up and down between 30° and 80?[...]

  • Page 10

    10 GB The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function. Instead of the -button for setting the actual time and for [...]

  • Page 11

    11 GB This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air , which includes a. a screen filter , to remove dust particles. b. an active carbon filter , to remove odours. 2. A screen filter in the lower air inlet, to emove dust particles. NOTE! The active carbon filte[...]

  • Page 12

    12 GB EMP T YING THE INTERNAL W A TER CO NT AINER Under high humidity conditions it may be necessary to empty the internal water container . When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically . T o empty the water container do the following: • Switch off the unit and remove t[...]

  • Page 13

    13 GB WARNING! First of all switch off the unit and remove the plug from the wall socket. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. Clean the air filters regularly , see the “air filter” section. NOTE! Never use the air conditioner without the screen filters. CLE [...]

  • Page 14

    14 GB Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property . Problem Cause Solution The air conditioner does not function. No power supply . Connect to a functioning outlet and switch on. Is the LCD light fl ashing. Empty the internal water container [...]

  • Page 15

    15 GB Reminder: W aste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. TECHNI CA L DA T A Model PMMBI* 9KE-410 PMMBI* 12KE-410 PMMBI* 15KE-410 Cooling capacity measured conform EN 14511 BTU/h 7500 9400 11300 kW 2.2 2.75 3.3 Power consumption kW 0.8 1.0[...]

  • Page 16

    Hong Kong 0 6 2 4 2 1 3 1 9 - I M M P China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amco[...]