A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion 10000 VA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion 10000 VA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion 10000 VA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of American Power Conversion 10000 VA should contain:
- informations concerning technical data of American Power Conversion 10000 VA
- name of the manufacturer and a year of construction of the American Power Conversion 10000 VA item
- rules of operation, control and maintenance of the American Power Conversion 10000 VA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion 10000 VA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion 10000 VA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion 10000 VA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion 10000 VA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    990-268 7B 04/2 006 User Manual English APC Smart-UPS ® RT – UXI/UXICH 8000/100 00 VA 220/23 0/240 VAC Tower/Ra ck-Mount 6U Uninterrupti ble Power S upply[...]

  • Page 2

    [...]

  • Page 3

    1 Introduction The APC Sm art-U PS® RT is a hi gh-perf ormance, unin terruptibl e pow er supply (UPS) t hat provides protection for electron ic equipm ent from utility power blackou ts, brownouts , sags and surges . The UPS filters small utilit y line fluctuations and isolates electronic equip ment from large disturbances by in ternally disconnect[...]

  • Page 4

    2 A TTACH THE B EZEL TO TH E UPS H ARDWIRING I NST RUCTIONS • Wiring must be perform ed by a qu alif ied electrici an. • Adhere to all national and local electrical codes. • Install a utility circuit breaker for input wiring, (see tables belo w ). 220/230/ 240 V M ODELS Input Connectio ns Output Connectio n (optional) Singl e- Phase : W ire t[...]

  • Page 5

    3 1. Switch the UPS input circuit breaker (see A in diagram ) and utility circuit breakers OFF. 2. Remove the input acces s panel, (see B in diag ram). 3. Remo ve circ ular knoc kout. 4. Run appropriate size w ire through the acces s panel, and connect to th e terminal block, (Green: Ground, Brown: Hot, Blue: Neutral). Connect the ground wire first[...]

  • Page 6

    4 C IRCUIT B REAKERS 8000/1000 0 VA Input Circ uit Break er The input circuit breaker must be s w itched on for the UPS to o perate. The input circuit break er protects the UPS from extreme overload conditions. 8000/1000 0 VA Output Circuit Break ers B ASIC C ONNE CTORS Serial Com Power management sof tware and interface ki ts can be used w ith the[...]

  • Page 7

    5 C ONNECT THE E X TERNAL B ATTERI ES Ba tte ry Sa fety Read and adhere to the follow ing warnings when installing or servicing the external batteries. Failure to observe these warn ings may result in serious injury, d eath or dam age to the equipment. W ARNINGS • Do not attempt to install or service external batteries alo ne. A qualified electri[...]

  • Page 8

    6 T HIRD P ARTY B ATTERY S OLUTION Batteries mu st be Seal ed Lead-Acid ty pe. Use 50 A, 250 V DC fu ses with an Interrupt rating of ≥ 20,000 A . Ensure that the extern al batteries are wired prior to connecting the batteries to the UPS. Two se parate, isol ated 192 V bat tery systems are requ ired wh en using a th ird party battery solution. One[...]

  • Page 9

    7 C ONNECT E QUIP MENT AND P OWER TO TH E UPS 1. Connect equ ipment to the UPS. 2. Turn on all conn ected equipment. To use the UPS as a master ON/OFF switch, ensure all connected equ ipment is switched ON. The eq uipment will not be po w ered until the UPS is turned on . 3. Switch the utility circuit breaker o n. 4. To power u p the UPS press the [...]

  • Page 10

    8 T ERMI NAL M ODE TO C ONFI GURE UPS P AR AMETER S AND P ROGRAM THE N UMBER OF B ATTERY P ACKS Terminal Mode is a menu driven interface that enables enhanced configuration of the UPS. Connect the serial cable f rom the computer to the serial com conn ector on the back of the UPS. Instru ctions for use with Pow erChute  Ne twork Shutdow n softwa[...]

  • Page 11

    9 O PERA TION Load S MART -UPS RT F RONT D ISPLAY Battery Charge Indicator Description Online The Online LED il luminates w hen the UPS is drawing ut ility pow er and perf orming double con versi on to su pply power to con nected equi pment. On Battery The UPS is supplying battery power to the con nected equipm ent. Bypass The Bypass LED ill uminat[...]

  • Page 12

    10 Feature Function Normal/Bypa ss Manual bypass enables t he user to manually put con nected equipment into bypass mode. Wh ile in by pass mode th e utility power bypas ses the UPS and g oes directly to the connected equipment. Batter y operation is not available wh ile the UPS is in bypass mode. R efer to Tr oubleshoot ing in this manual. Cold St[...]

  • Page 13

    11 U SER C ONFIGU RA B LE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTW ARE , S MA R T S LO T ACCESSORY CARDS , OR T ERMINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automa tic Self -Tes t Every 14 day s (336 hours) Every 7 day s(168 hours ), 14 day s (336 hour s) On Startup Only, No Self-[...]

  • Page 14

    12 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTW ARE , S MA R T S LO T ACCESSORY CARDS , OR T ERMINAL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION High By pa ss Point +10% of output voltag e setting +5%, +1 0%, +15%, +20% Maximum voltag e that the U PS will pass to c onnected equipm ent during inte r[...]

  • Page 15

    13 C ONNECT THE EPO (E MERGENCY P OWER O FF ) The output pow er can be disabled in an em ergency by closing a switch connected to the EPO. Adhere to national and local electrical codes wh en wiring the EPO. Wiring must be performed by a qualified electrician. The switch should be connected to a normally open switch contact. External voltage is not [...]

  • Page 16

    14 M AI N T E N AN C E , S ERVICE Battery Repla cement See your dealer or contact A PC at the Web site, www .apc.com for inf ormation on replacement battery modu les. Service If the UPS requires service do not return it to the dealer. Follow these s teps: 1. Revi ew the problem s dis cussed in th e Troubles hooting s ection of this manual to elimin[...]

  • Page 17

    15 T ROUBLESHOOTING Use the table below to solve minor installation and op eration problems. Refer to the AP C Web site, www.apc.com , for assistan ce with complex UPS problems. P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batt ery not conn ected p roper ly. Chec k tha t the bat tery connect ors a re full y engaged. butt on not pus[...]

  • Page 18

    16 P ROBLEM AND P OSSI BLE C AUSE S OLUTION BYPASS LED ILLUM INATE S The bypass swit ch ha s bee n turne d on manu ally o r thro ugh an acce sso ry . If bypa ss is t he chosen mode of oper ation, ignore the illuminated LED. If bypa ss is not the chos en mode of op erat ion move the b ypas s swit ch on the back o f the U PS, to the norm al position.[...]

  • Page 19

    17 R EGULA TOR Y A ND W AR R AN T Y I NFORMA T ION Regulatory Agenc y Approvals a nd Radio Freque ncy Warnings 220, 230, 24 0 V MODEL S This e qui pment has be en te sted and foun d to com ply w ith the limi ts fo r a Clas s A digi tal dev ice, p ursua nt to Par t 15 of the FCC ru les. Th ese lim its are desi gned to provid e reason able pr otect i[...]

  • Page 20

    18 Declaration of Conformity[...]

  • Page 21

    19 A PC Worldwide Customer Support Custom er support f or this or any other APC product is available at no ch arge in any of the fol lowing wa ys: • Refer to th e APC Web site to access docum ents in the APC Knowledge Base and to su bmit customer su pport reques ts. • www.apc.com (Corporate H eadquarters ) Connect to localized A PC Web sites fo[...]