Go to page of
Similar user manuals
-
Power Supply
American Power Conversion 2200 VA XL
19 pages 1.02 mb -
Power Supply
American Power Conversion AP9825I
1 pages 0.02 mb -
Power Supply
American Power Conversion PD80KG6FK1-M
92 pages 2.72 mb -
Power Supply
American Power Conversion MX28B-PDF
15 pages 0.33 mb -
Power Supply
American Power Conversion MX28B-400
46 pages 0.59 mb -
Power Supply
American Power Conversion 5000
60 pages 1.37 mb -
Power Supply
American Power Conversion 240 VAC
21 pages 0.39 mb -
Power Supply
American Power Conversion SYMSTRF3I
68 pages 5.63 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion 100VAC, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion 100VAC one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion 100VAC. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion 100VAC should contain:
- informations concerning technical data of American Power Conversion 100VAC
- name of the manufacturer and a year of construction of the American Power Conversion 100VAC item
- rules of operation, control and maintenance of the American Power Conversion 100VAC item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion 100VAC alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion 100VAC, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion 100VAC.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion 100VAC item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
990-1084A 09/02 User’s Manual English APC Smart APC Smart APC Smart APC Smart- - - -UPS UPS UPS UPS ® ® ® ® 1000/750 VA 230/120/1 00VAC 1000/750 VA 230/120/1 00VAC 1000/750 VA 230/120/1 00VAC 1000/750 VA 230/120/1 00VAC 1U Rack Mount 1U Rack Mount 1U Rack Mount 1U Rack Mount Uninterrupti ble Power Supply Uninterrupti ble Power Supply Uninterr[...]
-
Page 2
[...]
-
Page 3
1 Introduction American Po w er Conversion Corp oration (APC) is the leading national and internatio nal manufac- turer of state-of- the-art unin terruptibl e power su pplies, redundant sw itches, power m anagement soft- ware, an d related equipm ent. APC products protect hardw are, software, an d data from power distur- banc es in b usi ness a nd [...]
-
Page 4
2 Installing the R ails in the Rack The UPS fits in a standard 46. 5-cm (19- inch) rack. Mounting brack ets and rails are packaged s epa- rately within the main box . Cleats for rack mounting are preins talled on the UPS. 8 8 2[...]
-
Page 5
3 Mounting the UPS in a Rack The UPS is heavy. To lighten it, y ou may rem ove t he battery before mounting the unit in the rack (Steps 1 an d 2). Install the UPS at or near the bottom of the rack . Check to make sure the rack w ill not tip after installing the UPS into the rack. Step B Step A Step 1 Step 2 Be careful-the battery is heavy. Step 3 S[...]
-
Page 6
4 Installing and Connecting the Battery and Attaching the Front Bezel Connecting Equipment and Power to the UPS S MART - UPS R EAR P ANEL 230V Models 120/100V Model s Step 1 Step 2 Step 3 Step 4[...]
-
Page 7
5 1. Connect equi pment to the UPS. Note: Do not connect a laser printer to the UPS. A laser printer d raws signifi cantly more p ower than other type s of equipm ent and m ay overload the UPS . 2. Add any option al accessories to the Smart-Slot. 3. Using a pow er cord, plug the UPS into a tw o-pole, three-wire, grounded receptacle only . Avoid u s[...]
-
Page 8
6 2: O PERA TION S MART - UPS F RONT P ANEL 230/100V Model s 120V Models Power On Power Off Online The online LED illuminates when the UPS is supplying utilit y power to the connected equipment. If the LED is not lit, the UPS is either not turned ON, or is supplying battery power.[...]
-
Page 9
7 AVR Tri m This LED illuminates to indicate the UPS is compensating for a hig h utility voltage. AVR Boost This LED illuminates to indicate the UPS is compensating for a low utility voltage. On Battery When the on batter y power LED is lit th e UPS i s supplying battery power to the con nected equipment. When on battery, the UPS sounds an alarm—[...]
-
Page 10
8 3: U SER C ONFIGU RA BLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE S OFTWARE OR OPTIONAL S MART S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automa tic Self -Test Every 14 day s (336 hours) Every 7 days (168 hours) , On Startup Only, No Self-Te st This func tion sets the interv[...]
-
Page 11
9 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE S OFTWARE OR OPTIONAL S MART S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warning. PowerChute in terface softw are prov ides auto- matic, unatte nded shut- down w hen appr oxim ately two m inutes (by def ault) of battery opera ted [...]
-
Page 12
10 4: S TO R AG E , M A INT ENA NCE , A ND T RANSPORTING Storage Store the UPS covered and positioned as for proper functioning, in a cool, dry location, with the bat- teries fully charged. At -15 t o +30 ° C (+5 to + 86 ° F), charge th e UPS battery every six months. At +30 t o +45 ° C (+86 to +11 3 ° F), charge the UPS battery every three m o[...]
-
Page 13
11 5: T ROUBLESHOOTING Use the chart belo w to sol ve minor Smart-UPS installation and operation problems. Re fer to the APC web site, www.apc.com , for assistance with complex UPS problems. P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batter y not conn ected prop - erly. Check that the battery conn ector is full y engaged. butto n[...]
-
Page 14
12 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HE OVERLOAD LED IS LIT AND THE UPS EMITS A SUSTAINED ALARM TONE The UPS is overloaded. The conn ected equ ipment exceed s the sp ecified “maxi mum load” as d e- fine d in Spec ifications at the A PC we b site, www .apc.com . The alarm remai ns on un til the overload i s removed. Discon nect non esse[...]
-
Page 15
13 P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS OPERATES ON BA TTERY ALT HOUGH NORMAL LINE VOLTAGE EXISTS UPS input circuit breake r tripped. Reduce the load on the U PS by unpl ugging equipm ent and res etting the circuit br eake r (on the ba ck of UPS) by pre ssing the plunge r in. Very high, low , or dist orted li ne voltage. Inexpen sive fuel p[...]
-
Page 16
14 Service If the UPS requires s ervice do not return it to the dealer. Ins tead, follo w these steps: 1. Revi e w the problems discussed in t he Troubles hooting secti on of this m anual to eliminate com- mon probl ems. 2. If the problem persists, contact APC Customer Service th rough the APC web site, www.apc.com/su pport . Note the m odel nu[...]
-
Page 17
15 6: R EGULA TOR Y AND W AR R ANT Y I NFORMA T ION Regulatory Agency Approvals and Radio Frequency Warnings 230V MOD ELS This is a Class A prod uct. I n a dom estic env ironm ent this product m ay cause ra dio int erferenc e, in which cas e the u ser ma y be req uired to tak e correc ti ve ac- tions . 120V MOD ELS This e quipm ent h as be en tes t[...]
-
Page 18
16 Declaration of Conformity Limited Warranty American Power Conversion (APC) warrants its products to be free from defects i n materia ls and workmanship for a period of two years from th e date of pu rchas e. Its obli gati on under thi s warrant y is limit ed to repai ring or rep lacin g, at it s ow n sol e o p- tion, any such defect ive produ ct[...]