Go to page of
Similar user manuals
-
Power Supply
American Power Conversion 3000VA 3U
25 pages 0.48 mb -
Power Supply
American Power Conversion BK350
2 pages 0.46 mb -
Power Supply
American Power Conversion RS 500
2 pages 0.73 mb -
Power Supply
American Power Conversion 3000
60 pages 1.37 mb -
Power Supply
American Power Conversion PMH3XLM
13 pages 0.25 mb -
Power Supply
American Power Conversion ES 550
2 pages 0.28 mb -
Power Supply
American Power Conversion SYTF2
17 pages 1.1 mb -
Power Supply
American Power Conversion DP300E series
12 pages 1.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion 475I, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion 475I one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion 475I. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion 475I should contain:
- informations concerning technical data of American Power Conversion 475I
- name of the manufacturer and a year of construction of the American Power Conversion 475I item
- rules of operation, control and maintenance of the American Power Conversion 475I item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion 475I alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion 475I, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion 475I.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion 475I item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Back-UPS ™ 325I/475I User’s Manual 990-2114 8/01 Installation 2 Connect Equipment The rear panel of the Back-UPS consists of the following elements: Battery Back Up Outlets (qty. of 3) . These outlets provide battery back-up, surge protection, and Electro-magnetic Interference (EMI) filtering. In case of power outage, battery power is automatic[...]
-
Page 2
Back-UPS does not power computer/monitor/external drive during an outage Internal battery is not connected. Computer, monitor or external disk/ CD-ROM drive is plugged into a Surge Only outlet. Check the battery connections. (See “Connect the Battery” under “Installation” on the front page of this document. Move computer, monitor, or extern[...]