Go to page of
Similar user manuals
-
Power Supply
American Power Conversion 700
2 pages 0.46 mb -
Power Supply
American Power Conversion AmpMeter PDU
52 pages 1.07 mb -
Power Supply
American Power Conversion CTSLP/G
14 pages 0.42 mb -
Power Supply
American Power Conversion 110, 120, 230
16 pages 0.16 mb -
Power Supply
American Power Conversion 240 VAC
21 pages 0.39 mb -
Power Supply
American Power Conversion AP9222EXP
43 pages 0.59 mb -
Power Supply
American Power Conversion 3000
60 pages 1.37 mb -
Power Supply
American Power Conversion 1400XLT
30 pages 0.87 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion AP7562J, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion AP7562J one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion AP7562J. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion AP7562J should contain:
- informations concerning technical data of American Power Conversion AP7562J
- name of the manufacturer and a year of construction of the American Power Conversion AP7562J item
- rules of operation, control and maintenance of the American Power Conversion AP7562J item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion AP7562J alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion AP7562J, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion AP7562J.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion AP7562J item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Basic and Meter ed Rack Power D istribution Un it AP7862J AP7562J Installation and Quick -Start Ma nual[...]
-
Page 2
This manual is available in English on th e enclosed CD.[...]
-
Page 3
Contents Basic an d Metered Ra ck Pow er Distr ibution Unit i Produ ct Description and Invent ory . . . . . . . . . . . . . . . . . . . . . . 1 Descr iption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Additio nal docume ntation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Invento ry . . . . . . .[...]
-
Page 4
ii Basic an d Metered Ra ck Pow er Distr ibution Unit Warrant y and Ser vice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Limited w arranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Warrant y limi tations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Obtain ing s ervice . . . .[...]
-
Page 5
Basic an d Metered Ra ck Pow er Distr ibution Unit 1 Pr oduct Description and Inventory Description Thi s manual pr ovides in formation on i nstalli ng and oper ating the followi ng three- phase Rack Power Dist ributio n Units ( PDU s): Metered PDU AP7862J: NEMA L21-20 plug 42 NEMA 5-15 outl ets Basic PDU AP7562J: NEMA L21-20 plug 42 NEMA 5-15 outl[...]
-
Page 6
Product Descript ion an d Inventory 2 Basic an d Metered Ra ck Pow er Distr ibutio n Unit Additiona l documentatio n The Meter ed Rack P D U User ’ s Guide and the Metered Rack PDU Addendum a re avail able on th e supplied CD or on ou r W eb si te: http://www .apc.com/ . The onlin e user ’ s guide (. Docengusr guide.pdf ) contai ns additi on[...]
-
Page 7
Basic an d Metered Ra ck Pow er Distr ibution Unit 3 How to Install the Ba sic and Meter e d PDU Attach the cor d r etention tray s Attac h the cord r etent ion tra ys to the PDU , usin g four flat-he ad screws (provid ed) per tray . Attach cor ds to the tray Attach a cord to the tra y by looping the cord and s ecuring i t to the tray , using a wi [...]
-
Page 8
How to Install the Basic and Metered PDU 4 Basic an d Metered Ra ck Pow er Distr ibutio n Unit T oo lless mounting 1. Slide t he mounting pe gs into the holes loca ted in the channel i n the rear pa nel of the enclo sure. 2. S nap t he PDU into plac e by pushing it downwar d until it locks i nto positi on. Note Y ou can mount two PDU s on one side [...]
-
Page 9
How to Install the Basic and Metered PDU Basic an d Metered Ra ck Pow er Distr ibution Unit 5 Bracket-mo unting Y ou can or der a rack -mount bracket ki t from APC ( AR8116BLK) . The bracket s attach to the PDU in either of two direc tions, shown in the figure s in step 1. Consider the ori entati on of the PDU in the enclo sure before a t tachin g [...]
-
Page 10
How to Install the Basic and Metered PDU 6 Basic an d Metered Ra ck Pow er Distr ibutio n Unit 2. Insert mounting screws (p rovided with the bracket ki t) in the top and bott om positions in t he channel where t he brackets ali gn with the h oles. T ighten the screws t o secure t he PDU to the encl osure. – Recessed orientation – Raised orie nt[...]
-
Page 11
Basic an d Metered Ra ck Pow er Distr ibution Unit 7 Operation Disp lay inte rface (AP78 62J only) Link - Rx/Tx 10 / 100 Status Serial Port Rese t Pre ss to sele ct li ne. Pre ss a nd h ol d to in ver t d ispla y . - W ar ning - OK - Overl oad L3 L2 L1 Amps Amps Phase Indicator LED s: • Indicates the phase corr[...]
-
Page 12
8 Basic an d Metered Ra ck Pow er Distr ibutio n Unit Quick Configuration for a Meter ed PDU Over v iew Y ou must con figure the f ollowing TCP/IP settings before the PDU can operate on a network: • IP addr ess of the PDU • Subnet mask • De fault g atewa y TCP/IP configuration methods Use one of the following to define the TCP/IP settin gs: ?[...]
-
Page 13
Quick Config uration for a Metered PDU Basic an d Metered Ra ck Pow er Distr ibution Unit 9 BOOTP & DHCP configuration The Boot Mode setting, a TCP/IP opt ion in th e PDU ’s Network menu, identi fies how TCP/IP settin gs will be defined. Th e possibl e settings are Manual , DHCP only , BOOTP only , and DHCP & BOOTP (the defaul t setti ng)[...]
-
Page 14
Quick Conf igurati on for a Metered PDU 10 Basic an d Metered Ra ck Pow er Distr ibution Unit DHCP . Y ou can use a RFC2 131/RFC2132 -com plian t DHCP server to configur e the TCP/IP se ttings for t he PDU . 1. The PDU sends a DH CP reques t that uses the following to identif y itself : – V endor Cla ss Identi fier ( APC by de faul t) – Client [...]
-
Page 15
Quick Config uration for a Metered PDU Basic an d Metered Ra ck Pow er Distr ibution Unit 11 Local access to the contr ol console Y ou can use a local computer to connect to the PDU to access t he control console. 1. Select a serial port a t the local compu t er , and dis able any servic e which uses that port. 2. Use the c onfiguration c able (940[...]
-
Page 16
Quick Conf igurati on for a Metered PDU 12 Basic an d Metered Ra ck Pow er Distr ibution Unit 3. Use T elnet to access the PDU at its newly ass i gned IP a ddress. For example: telnet 156.205.14.141 4. Use apc for bot h User Name and Password. 5. See “Contr ol console” on t his page t o finish the con figurati on. Contr ol console After yo u lo[...]
-
Page 17
Basic an d Metered Ra ck Pow er Distr ibution Unit 13 How to Access a Configur ed PDU Over v iew After t he PDU is r unning on your network, you c an use se veral dif ferent interf aces to access the PDU . Br o wser interface As your br owser , use Microsoft ® In ternet Explorer 5.5 (or h ighe r) to configur e PDU options or t o view the Event log[...]
-
Page 18
14 Basic an d Metered Ra ck Pow er Distr ibution Unit How to Recover Fr om a Lost Passwor d Y o u can use a lo cal c omp uter that con nect s to t he PDU through t he serial port on t he front panel of the unit. 1. Select a serial port at a local co m pute r , and disabl e any servic e that uses the port. 2. Use the c onfiguration c able (940-01 44[...]
-
Page 19
Basic an d Metered Ra ck Pow er Distr ibution Unit 15 Specifications AP786 2J/AP75 62J Electrical Nominal in put voltage 173 V , 3-phase Acceptable input voltage ± 10 % Nominal input voltage Inpu t fr eque ncy 47 – 63 Hz Input connectors NEMA L21-20 plug Output connecto rs 42 NEMA 5- 15 outlet s Maximum tot al current dr aw 20 A per Phas e Physi[...]
-
Page 20
16 Basic an d Metered Ra ck Pow er Distr ibution Unit W arranty and Service Limited war ranty APC warrants the PDU to be free fr om de fec ts in ma teri als an d workmanshi p for a per iod of two years f rom the date of pu rchase. I ts obligat i on und er this wa rranty is limited to repairing or replaci ng, at it s own sole op tion, any such def e[...]
-
Page 21
Basic an d Metered Ra ck Pow er Distr ibution Unit 17 Life-Support Policy General po licy American Po wer Conversion ( APC ) does not recommend the use of any of its produ cts in the f ollow ing situat ions: • In lif e-support applications where fa ilure or malfuncti on of the APC product can be reasonably exp ected to c ause failure o f the life[...]
-
Page 22
[...]
-
Page 23
Radio Fr equency Interfer ence This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inte rference when the equipment is operated in a commercial environment. This equipment generates, uses, and[...]
-
Page 24
APC W orldwide Customer Support Customer s upport for this or any other APC product is avai lable at no char ge in any of the following ways : • V isit th e APC W eb site t o find answers to fr equently asked ques tions ( FA Q s), to acces s documents in the APC Knowledge Ba se, and to s ubmit customer sup port reque sts. – www .apc.com ( Corpo[...]