American Power Conversion AP9604S manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion AP9604S, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion AP9604S one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion AP9604S. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of American Power Conversion AP9604S should contain:
- informations concerning technical data of American Power Conversion AP9604S
- name of the manufacturer and a year of construction of the American Power Conversion AP9604S item
- rules of operation, control and maintenance of the American Power Conversion AP9604S item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion AP9604S alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion AP9604S, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion AP9604S.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion AP9604S item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    APC Silcon 240-320kW 400V UPS Installation Guide Copyright 2001 APC Japan Inc This manual is subject to change without notice and does not represent a commitment on the part of the vendor[...]

  • Page 2

    2 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Thank You! Thank you for chosing the APC Silcon Series UPS. Please read this Installation Guide thoroughly prior to installing the system. It provides important information on safe and efficient installation. The installation and use of this product must comply with national, federal, stat[...]

  • Page 3

    Introduction 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 3 1.0 Introduction Power regulation varies from area to area, and information given in this installation guide can therefore only be of a general nature. Electricians should therefore always refer to national and local electrical codes prior to installing the UPS system. 1.1 Too[...]

  • Page 4

    4 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Unpacking 2.0 Unpacking 1. To unpack UPS unit, remove top and bottom screws from side plates of packaging and lift up side plates 2. Verify compliance between type label on reverse side of front door and system ordered. Check input and output voltage 3. Copy type label data to label copy b[...]

  • Page 5

    Installation 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 5 3.0 Installation 3.1 Requirements on Site All system parts are accessible from front or top of UPS. Cable entries are accessible from bottom. A 1-metre free space on all sides should be allowed during installation. After installation of the UPS, leave a free space of 600 mm to[...]

  • Page 6

    6 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Installation 3.2 Footprint 3.2.1 1600mm Cabinet for 240-320kW UPS 3.2.2 825mm Cabinet for Isolation Transformer or Switch Gear Power cable entry com. cable entry Rear Front Rear Power cable entry ?[...]

  • Page 7

    Installation 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 7 3.2.3 1600mm Cabinet for 320kW Isolation Transformer Rear Power cable entry Front ?[...]

  • Page 8

    8 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.0 External Connection 4.1 Connecting the UPS NOTICE! Check correct phase rotation of mains input voltage!! Max. input/output cables: 3//300 mm 2 . If there is no neutral input Dzn0 or Dyn11 input isolation transformer is required. CAUTION! This UPS unit is an EN 50091[...]

  • Page 9

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 9 PVC cables insulated to withstand ambient temperature of max. 30°C ** Must be rated as external PE cable if mains system is not supplying PE UPS External Input Fuses* FM [A] 380-415V External Input Cable [mm2] 380-415V External PE Cable [mm2] Maximum External Output Fu[...]

  • Page 10

    10 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.2 System Integration Interface System Integration Interface (SII) is the control link between UPS and system main switches as shown in above diagram. The purpose of the SII is to ensure correct operation of switches without losing system output power. Auxiliary conta[...]

  • Page 11

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 11 4.2.1 Connections Blue Brown[...]

  • Page 12

    12 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection Terminal Blocks: X003/X004 (Anxiliary Contacts) When switching Q001, Q002, Battery Breaker 1 or Battery Breaker 2 from “ON or 1” to “OFF or 0”, the anxiliary contact has to be open BEFORE the corresponding main contacts are opened. When switching Q001, Q002, Ba[...]

  • Page 13

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 13 4.3 Parallel Board The built-in parallel board connects two or more UPS systems in parallel, either to obtain increased system reliability or to obtain higher output power. The parallel board also ensures correct load-sharing between paralled systems. To prepare the UP[...]

  • Page 14

    14 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection External Control Cables External multicore cable is equipped with 15-pin SUB-D plug at either end. Connect pin 1 to pin 1, and pin 2 to pin 2 etc. up to pin 15 - with the exception of pin 8, which is not to be connected. Shield is connected to plug cover at both ends. [...]

  • Page 15

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 15 4.4 Relay Board Relays All relays are “fail safe”: In alarm modes, relay coil will be de-energized. Maximum load: 8.0A – 250VAC Minimum load: 0.05A – 6VAC 1 2 3 0.3A – 60VDC 0.05A – 6VDC[...]

  • Page 16

    16 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.4.1 Relay Board/Relay Functions ## Delay programmable in configuration stack : “ Common fault delay ” . Settings 0,10,20,30 seconds. NOTICE If alarm mode “ Communication to controller lost ” is active, ALL relays will indicate failure Relay Number Message Ala[...]

  • Page 17

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 17 See section 5.2: System configuration NOTICE! Alarm Trigging Events 1-2-3-9-10-11-13 activates the corresponding alarm relay after the delay. Alarm Trigging Events 4-5-6-7-8-12-14-15 activates the corresponding alarm relay momentarily. Common fault relay 16 is activate[...]

  • Page 18

    18 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.5 Communication Interface Board The 3-port ComInterface is used to establish an interaction between UPS and e.g. a computer system. Main purpose: To ensure a controlled computer shut-down in case of a mains supply failure. 4.5.1 Connections . .[...]

  • Page 19

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 19 4.6 Connecting of APC Silcon Tripel Chassis The enclosed Triple Chassis must be connected to the serial port on the Communication Interface Board, and to the 24V supply (cables included). Terminal locations shown below. For more information please refer to the followin[...]

  • Page 20

    20 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.7 APC Silcon Triple Chassis The APC Silcon Triple Chassis (AP9604S) is an American Power Conversion (APC) external management peripheral that allows you to use monitoring and control management peripherals with your APC Silcon series UPS. The retrofit model (AP9604SR[...]

  • Page 21

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 21 4.7.2.3 LEDs The APC Silcon Triple Chassis status LED provides important information concerning operation of the chassis. Refer to the table below for a description of the conditions indicated by the LED. 4.7.2.4 Optional Power Input With the Optional Power input, you [...]

  • Page 22

    22 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.7.3.1 Order of Management Peripheral Cards Because UPS signals are passed between management peripherals, you must install management peripheral cards in the correct order for them to work together properly. The card slots are numbered 1 to 3, from left to right, as [...]

  • Page 23

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 23 To add card slots, you can daisy-chain the APC Silcon Triple Chassis with the standard Triple Chassis (AP9604) management peripheral, installing the APC Silcon Triple Chassis closer to the UPS. 4.7.4 Powering the APC Silcon Triple Chassis The APC Silcon Triple Chassis [...]

  • Page 24

    24 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.7.5 Troubleshooting The following table shows the solution to common problems with the operation of the Triple Chassis 4.7.5.1 If Problems Persist For problems not covered in the troubleshooting chart or for persistent problems, follow this procedure: 1) Note the ser[...]

  • Page 25

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 25 4) Pack the APC Silcon Triple Chassis carefully in its original packaging, if possible. Do not use polystyrene beads for packing. Damage sustained in transit is not covered under the warranty. Enclose a letter in the package with your name, address, RMA number, a copy [...]

  • Page 26

    26 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection UPS Shut Down RS-232 Input or Advanced Mode RS-232 Data RX In Line Fail RS-232 Output or Advanced Mode RS-232 Data TX Out Unregulated +24 VDC Output Normally Open Line Fail Signal Normally Open Low Battery Signal Normally Closed Line Fail Signal Common Chassis[...]

  • Page 27

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 27 4.7.6.2 Power, Physical, and Environmental Specifications. Item Specification Power Turn on voltage: > 22 VDC Turn off voltage: < 16 VDC Current draw (normal operation): 90 mADC Current draw (voltage < 16 VDC ): < 1 mADC Physical Size (H xW x D): 44 x 432 x[...]

  • Page 28

    28 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.8 APC Silcon Battery Cabinets Installation and use of this product must comply with all national, federal, state, municipal or local codes. If you need assistance, please have your UPS model and serial number ready and call APC, see “How to Contact APC” in this g[...]

  • Page 29

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 29 4.8.0.6 Installation of Batteries See Installation Guide for Battery Cabinet for: • Preparing Batteries and UPS • Dimensions and Weight • Connecting Batteries 4.9 Battery Breaker Box/Fuse-box Battery Breaker Box/Fuse-box provides overcurrent and short-circuit pro[...]

  • Page 30

    30 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.9.1 Battery Breaker Box Battery Breaker Box/ Fuse-box Battery APC Silcon UPS ?[...]

  • Page 31

    External Connection 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 31 4.9.2 APC Battery Breaker Box Connection Diagram (120-480kW) X009 LED signal from UPS “ OK to operate corresponding MCCB ” X010 MCCB position signals for UPS X011 Trip for emergency stop (220-240V AC) UPS Ampere Rating [A] Connection Cable [mm2] Max. short- circuit[...]

  • Page 32

    32 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 External Connection 4.9.3 UPS with External Battery in Battery Breaker Box/Fuse-box Configuration ?[...]

  • Page 33

    Programming Parameters 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 33 5.0 Programming Parameters Below table shows operating parameters programmable from keyboard. Only qualified users should re-set programming parameters. 5.1 Parameters * Factory settings in bold ** Only for systems with Battery Monitor active *** Do not leave system[...]

  • Page 34

    34 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Programming Parameters 5.1.1 Programming Keys NOTICE! Display accuracy is + 1%, + digit. Scrolls up through list Scrolls down through list Stores parameters/ enter parameter stack Silences the audible alarm Chooses parameters Displays time Exits a mode Accesses alarm stack[...]

  • Page 35

    Programming Parameters 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 35 5.1.2 Programming Example - Switch to Bypass Operation Return to normal operation Follow same procedure to program other parameters. 5.2 System Configuration System configuration parameters are vital for correct system operation and are password- protected. NOTICE! [...]

  • Page 36

    36 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Programming Parameters System Configuration Parameters (password protected) * Bold text refers to factory standard setting **Advanced Battery Monitor Parameter Setting* Comments Enter System no. Voltage L-L 380, 400 , 415 Optional selection of voltage System Frequency 50 /60 Optional sele[...]

  • Page 37

    Programming Parameters 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 37 *** If voltage or frequency settings is changed, unit needs to be powered down for the new settings to take effect. 5.2.1 Programming Example - Change Charge Voltage to 446 NOTICE! Change charge voltages, battery warning limit, shut down voltage and high battery tem[...]

  • Page 38

    38 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Programming Parameters 5.2.2 Programming Example - Change to Output Isolation Transformer available NOTICE! Change parameters by pressing the key once or several times. See example above.[...]

  • Page 39

    Programming Parameters 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 39 5.3 Programming Parameters for Advanced Parallel Operation To use the advanced parallel functions, the following parameters must be programmed: 1. “Station number” 2. “Highest station address” 3. “Advanced power management” 4. “APM test mode active” [...]

  • Page 40

    40 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Programming Parameters 5.3.2 Programming example Example with four systems in parallel with separate batteries. • Programme the station addresses 1-4: 1 for UPS 1, 2 for UPS 2, 3 for UPS 3, and 4 for UPS 4. • All UPS systems have to be programmed to “Highest station address”:4. ?[...]

  • Page 41

    Programming Parameters 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 41 5.4.1 Installation of new batteries To avoid false alarms, the above procedure MUST be followed. NOTICE! Contact your local dealer if you have any questions regarding changing parameters.[...]

  • Page 42

    42 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.0 Options/Accessories Please contact your local APC representative for information on options/accessories available in your region. See “How to Contact APC” in this guide. 6.1 Service Bypass Panel for Single Operation UPS Exter-nal System Input Fuse [A] Max. Pros[...]

  • Page 43

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 43 6.1.1 Wiring up UPS with SBP in TN-C-S Network 6.1.2 Wiring up UPS with SBP in TN-S Network ? ?[...]

  • Page 44

    44 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.1.3 Operating The External Service Bypass Switch Action 1. Press on the ke yboard 2. Press or on the ke yboard until 3. Press on the ke yboard 4. Press on the ke yboard 5. Check lamp indication on the Service Bypass Panel 6. T ur n the e xter nal bypass s witch (Q003[...]

  • Page 45

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 45 6.1.3.1 Switching from External Bypass to Normal UPS Operation ** System OFF ** Normal operation load power % Display sho ws Lamp indication on Servive Bypass Panel The Green lamp (H002) abov e the output switch handle (Q002) lights Now also the green lamp (H003) abov [...]

  • Page 46

    46 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.2 Service Bypass Panel for Parallel Redundant Operation Service Bypass Panel (SBP) Mains Supply System Output Control cables Q003 Q004 Q001b Q001a Q002b Q002a APC Silcon 400V UPS X020 X021 X020 X021 APC Silcon 400V UPS Battery Battery Breaker/ Fuse Box[...]

  • Page 47

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 47 6.2.1 Two Parallel Systems with Service Bypass Panel ?[...]

  • Page 48

    48 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.2.2 Parallel/Redundant Operation with Service Bypass Panel and External Battery via MCCB ?[...]

  • Page 49

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 49 6.2.3 Operating External Service Bypass Switch for Parallel Systems 6.2.3.1 Bypassing Parallel UPS Systems CAUTION! Batteries connected to a UPS out of service for a period exceeding 8 days may be damaged. H002a[...]

  • Page 50

    50 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories Step 1-4 can be carried out with any of the parallel systems, ho wever this will s witch all systems into bypass operation. 1. Press on the keyboard 2. Press or on the keyboard until 3. Press on the keyboard 4. Press on the keyboard All systems will transf er to bypass[...]

  • Page 51

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 51 6.2.3.2 Switching Parallel System from External Bypass into Normal UPS Operation H002a[...]

  • Page 52

    52 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories Action 1. Check that output s witch (Q004) is in position “ 0 ” 2. Check that all output s witches (Q002) are in position “ 0 ” 3. T ur n input switches (Q001) to position “ 1 ” 4. Open the UPS front door and press the green “ ON ” push-botton 5. Press [...]

  • Page 53

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 53 The follo wing can be carried out on any UPS 13. Press on the ke yboard 14 Press or on the ke yboard until 15. Press on the ke yboard 16. Press on the ke yboard All the systems will transf er to nor mal operation. Normal operation load power xx% Display sho ws Bypass o[...]

  • Page 54

    54 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.2.4 Isolating One UPS for Service/Maintenance In a redundant system, one UPS may be isolated for service/maintenance without affecting other UPSs. 1. Check that remaining UPS(s) is capable of carrying the load in the event that one UPS is isolated 2. Switch off syste[...]

  • Page 55

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 55 6.3 Intersystem Synchronization Unit Intersystem Synchronization Unit System (ISU System) The ISU system consists of inter-connected ISUs. One ISU system may consist of up to 5 ISUs, regardles of ISU configuration. The ISU system synchronizes the voltage of parallel op[...]

  • Page 56

    56 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.5 Remote Display With the remote display unit data may be displayed at distances of up to 25 m from UPS. For extended communication distance, see section below. Remote display may easily be connected to UPS via one of the two serial communication ports on the communi[...]

  • Page 57

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 57 Remote Display. The converter provides optical signal insulation. Both converter boxes must be supplied by an uninterruptible power source. 6.5.1.1 Connections Without Converter Connect a 25-pin female Sub-D and a 9-pin male Sub-D connector with a 3-wire shielded cable[...]

  • Page 58

    58 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.5.2 Remote Display Installation 6.5.2.1 Connecting RS232C and Mains Adapter 6.5.2.2 Remote Display Power Supply The remote display is supplied by normal AC power with no battery back-up. For UPS data transmission to remote display to remain unaffected during power fa[...]

  • Page 59

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 59 6.5.3 Remote Display Use The remote display is an inactive unit unable to influence the operation of the UPS: Some of the alarms visible on the internal display are also available on the remote display (See the Alarm section in the APC Silcon User Guide). 6.5.3.1 Initi[...]

  • Page 60

    60 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.6 Isolation Transformer Isolation Transformer UPS Height [mm]* Width [mm]* Depth [mm]* Weight [kg] 280kVA 370kVA 240kW 320kW 1800 1800 1200 1300 800 800 1500 1950 *Actual dimensions may vary 1600 mm wide 1800mm ? APC Isolation Transformer Module 320kW 800 mm wide 180[...]

  • Page 61

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 61 Example of Transformer Configuration (Yyno) NOTICE! APC isolation transformers are available in various configuration. Contact your local APC representative for further information. See “ How to Contact APC ” in this guide. Input Output E G G[...]

  • Page 62

    62 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.6.1 Connecting Isolation Transformer *DIN gL types PVC cables insulated to withstand a maximum ambient temperature of 30 o C *DIN gL types PVC cables insulated to withstand a maximum ambient temperature of 30 ° C Isolation Transformer UPS External Input Fuses* FM [A[...]

  • Page 63

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 63 NOTICE! If an MCCB is used in stead of external input fuses, the MCCB load capacity must be 8xIn (nominal current) for minimum 10 ms. NOTICE! Check correct phase rotation of mains input voltage! Maximum input/output cables: 3//300 mm 2 . If input neutral is not availab[...]

  • Page 64

    64 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.6.2 Wiring up UPS with External Yyn0 Isolation Transformer at Output WARNING! Isolation transformer provides galvanic isolation between mains supply and load. Load will loose galvanic isolation if isolation transformer is bypassed NOTICE! Refer to local legal regulat[...]

  • Page 65

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 65 6.6.3 Wiring up UPS with External Yyn0 ?????? Isolation Transformer at Input WARNING! Isolation transformer provides galvanic isolation between mains supply and load. Load will loose galvanic isolation if isolation transformer is bypassed. NOTICE! Refer to local legal [...]

  • Page 66

    66 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.6.4 Wiring up UPS with External Optional Dzn0 Isolation Transformer at Input WARNING! Isolation transformer provides galvanic isolation between mains supply and load. Load will loose galvanic isolation if isolation transformer is bypassed. NOTICE! Refer to local lega[...]

  • Page 67

    Options/Accessories 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 67 6.6.5 Wiring up UPS with External Optional Dzn0 Isolation Transformer at Output WARNING! Isolation transformer provides galvanic isolation between mains supply and load. Do not bypass isolation transformer in order to avoid damaging circulation currents and to prevent [...]

  • Page 68

    68 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Options/Accessories 6.6.6 Wiring up UPS with External Optional Dyn11 Isolation Transformer at Input WARNING! Isolation transformer provides galvanic isolation between mains supply and load. Do not bypass isolation transformer in order to avoid damaging circulation currents and to prevent [...]

  • Page 69

    System Specifications 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 69 7.0 System Specifications 7.1 Technical Data 7.2 Dimensions / Weight Voltage 3x380/400/415V Input Voltage tolerance Normal operation Bypass operation ±15% ±10% (standard) ±4, 6, 8% (programmable) Frequency 50Hz/60Hz ±6 standard ±0.5-8% (programmable) Input power[...]

  • Page 70

    70 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Warranty 8.0 Warranty 8.1 APC Silcon Series Limited Factory Warranty APC warrants that the unit, when properly installed and commissioned by APC or APC authorized service personnel, shall be free from defects in materials and workmanship for a period of (1) year from the date of installat[...]

  • Page 71

    Appendix 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 71 9.0 Appendix 9.1 Table 1. Installation Planning Data Notes: 1. Nominal input current based on rated load. 2. Maximum input current based on rated load + full battery recharge. Full battery recharge assumed to increase input current with 10%. 3. Nominal power consumption (column 1[...]

  • Page 72

    72 Installation Guide APC Silcon 240-320kW 400V UPS 990-4056 Appendix 6. Fuses according to DIN LV HRC type gL, 500V assumed. MCCB load capacity must be 8xIn (nominal current) for minimum 10ms. 7. Suggested load side overcurrent protection (3b) based on nominal output current (3a). 8. Nominal battery voltage assumed to be 2V/cell (Lead technologi).[...]

  • Page 73

    How to Contact APC 990-4056 Installation Guide APC Silcon 240-320kW 400V UPS 73 10.0 How to Contact APC APC Corporate 132 Fairgrounds Road West Kingston, RI 02892 USA Telephone: 401 789-5735 Fax: 401 789-3710 PowerFax™: 800 347-FAXX Pre-sales Technical Support 877-474-5266 (1-877-4Silcon) Post-sales Technical Support 877-287-7835 (1-877-2UPS-TEK)[...]