Go to page of
Similar user manuals
-
Switch
American Power Conversion MasterSwitch
12 pages 0.12 mb -
Switch
American Power Conversion AP7723
2 pages 0.11 mb -
Switch
American Power Conversion Automatic Transfer
25 pages 0.54 mb -
Switch
American Power Conversion AP9615
22 pages 0.37 mb -
Switch
American Power Conversion Bypass Static
56 pages 2.61 mb -
Switch
American Power Conversion Automatic Disconnect Switch
14 pages 0.47 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion AP9615, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion AP9615 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion AP9615. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion AP9615 should contain:
- informations concerning technical data of American Power Conversion AP9615
- name of the manufacturer and a year of construction of the American Power Conversion AP9615 item
- rules of operation, control and maintenance of the American Power Conversion AP9615 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion AP9615 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion AP9615, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion AP9615.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion AP9615 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
® 5 Port 10Base-T Hub AP9615[...]
-
Page 2
Thank Y ou! Thank you for selecting the APC SmartSlot 5 Port 10Base-T Hub (AP9615). It has been designed for many years of reliable, maintenance-free service in combination with your American Power Conversion (APC) uninterruptible power supply (UPS). APC is dedi- cated to the development of high-performance electrical power conversion and control p[...]
-
Page 3
i Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Overview 1 Features of the 5 Port 10Base-T Hub 1 Hardware requirements 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Front panel 2 APC Communications Compatibility Number 2 LEDs 3 Station ports 4 Uplink por[...]
-
Page 4
[...]
-
Page 5
1 Intr oduction Overview The SmartSlot ™ 5-Port 10Base-T Hub is an APC accessory that allows you to expand or create a local area network (LAN) by installing it in the SmartSlot of an APC UPS or expansion chassis. Featur es of the 5 Port 10Base-T Hub The following list shows some of the features of the 5 Port 10Base-T Hub. Y our hub… • Instal[...]
-
Page 6
2 Pr oduct Description Fr ont panel This figure shows the front panel of the 5 Port 10Base-T Hub. The features of the front panel are described in the paragraphs that follow . Figur e 1: Front Panel and Connect or Detail APC Communications Compatibility Number The APC Communications Compatibility Number ( CCN ), which appears on the upper left corn[...]
-
Page 7
3 Pr oduct Description continued LEDs The LEDs provide important information concerning opera- tion of the hub and each of its ports. Refer to the table below for a description of the conditions indicated by LEDs . Continued on next page Label Color Activity Description Pwr Green On The hub is receivin g p ower . Col Y ellow Blinkin g The network i[...]
-
Page 8
4 Pr oduct Description continued Station ports The Station ports are the first 4 RJ-45 ports, which are labeled 1X – 4X . The Station ports use straight-through UTP cables to connect the hub with: • W orkstations or other non-hub devices that you want to include in your network. • The Uplink port of another hub in a cascading config- uration.[...]
-
Page 9
5 Installing the Hub Wa r n i n g Do not operate the 5 Port 10Base-T Hub where conditions are outside the limits listed in “Product Specifications” on page 14. Installing on critical systems The installation procedure that follows may involve shut- ting off power from the UPS . However , if your setup requires maintaining power to connected equ[...]
-
Page 10
6 Installing the Hub continued Installation procedur e, continued Matrix- UPS ™ a Shut down and power off the connected equipment. b T urn off the circuit breaker on the bottom left side on the back panel of the UPS . Symmetra ™ Power Array ™ a Shut down and power off the connected equipment. b T urn off the System Enable switch on the bottom[...]
-
Page 11
7 Installing the Hub continued Installation procedur e, continued 3U s e a #2 Phillips head screwdriver to remove the 2 screws fastening the SmartSlot cover plate to the back panel of the UPS or triple chassis. Keep the screws for Step 5 below . Save the SmartSlot cover plate for future use (e.g. shipping the UPS ). 4 Orient the hub to fit into the[...]
-
Page 12
8 Installing the Hub continued Installation procedur e, continued 5 Secure the hub with the screws removed in Step 3. 6 Using straight-through UTP cables, connect the Sta- tion ports ( 1X – 4X , in any order) to each worksta- tion’ s 10Base-T port or to the Uplink port of a hub to be connected in cascade.(See Figure 2 on page 4.) 7 Connect the [...]
-
Page 13
9 Installing the Hub continued Installation procedur e, continued Symmetra Power Array a T urn on the System Enable switch on the bottom left side on the back panel of the UPS . b T urn on the UPS via the PowerV iew display . c Power on the connected equipment. Smart-UPS DP a T urn on the ON/OFF switch on the front panel. b Power on the connected e[...]
-
Page 14
10 Installing the Hub continued Maximum configuration Using a star configuration, you can cascade up to ten 5 Port 10Base-T hubs together to provide network connections for as many as 32 stations, as shown below in Figure 4. Note the use of a crossover cable to connect the Uplink ports of the 2 central hubs. Figur e 4: Cascading Hubs in a Star Conf[...]
-
Page 15
11 Removing the Hub Removal procedur e T o remove the 5 Port 10Base-T Hub, perform the following steps in the order given. 1 Disconnect all cables from the hub. 2 T urn off the UPS or device that houses the hub. (For detailed instructions, see “Installation procedure” on page 5.) 3U s e a #2 Phillips head screwdriver to remove the 2 screws fast[...]
-
Page 16
12 T r oubleshooting T r oubleshooting suggestions T a ble 2 provides suggestions for troubleshooting your hub. Continued on next page LED Action Cause Solution Col Blinkin g Normal data collisions on the network. No action is necessar y . Col Blinkin g excessivel y Data collisions are occurrin g because of a hi g h volume of traffic on the network[...]
-
Page 17
13 Tr o u b l e s h o o t i n g continued T r oubleshooting suggestions, continued LED Action Cause Solution Partition On 32 consecutive collisions have caused the p ort to p artition. Check that the correct cable is in use and verif y that the connected e q ui p ment is set to o p erate at 10 Mbit and half-du p lex mode. As collisions reduce, the [...]
-
Page 18
14 Specifications Pr oduct specifications The following table shows the product specifications for the 5 Port 10Base-T Hub. Item Specification Power In p ut volta g e ran g e: 18 – 30 VDC Maximum current draw: 45 mA Physical Size (H × W × D): 1.46 × 4.75 × 4.30 in (3.7 × 12.1 × 10.9 cm) We i g ht: 0.25 lb (0.1 1 k g ) Shi pp in g wei g ht: [...]
-
Page 19
15 W arranty Information Limited warranty American Power Conversion ( APC ) warrants the 5 Port 10Base-T Hub to be free from defects in materials and work- manship for a period of 2 years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective prod- ucts.This war[...]
-
Page 20
16 W arranty Information continued Obtaining service T o obtain service for your 5 Port 10Base-T Hub, follow this procedure: 1 Note the serial number and date of purchase of the hub. (The serial number is located on the top, interior surface of the hub’ s front panel.) 2 Contact APC Customer Support at the phone number or address on the back cove[...]
-
Page 21
Declaration of Conformity Application of Council Directives 89/336/EEC Standards to Which Conformity is Declared EN55022: 1995, Class B EN50082-1: 1992, including: IEC 1000-4-2: 1995 IEC 1000-4-3: 1995 IEC 1000-4-4: 1995 FCC Part 15, Class B VCCI, Class 2 Manufacturer’ s Name and Address American Power Conversion 132 Fairgrounds Road W est Kingst[...]
-
Page 22
www .apcc.com T oll-free Customer Suppor t: U. S. & Canada 1-800-800-4272 Austria 0660 6480 Belgium 0800 15063 Czech Republic 0 800 102063 Denmark 800 18 153 Finland 9800 13 374 France 0 800 906 483 Germany 01300818907 Holland 0800 0224655 Hungary 00800 12221 Ireland 1 800 702000 x 2045 Israel 177 353 2206 Italy 1678 74731 Japan 0120-80-60-90 L[...]