Go to page of
Similar user manuals
-
Power Supply
American Power Conversion BR1200GI
2 pages 0.46 mb -
Power Supply
American Power Conversion 750
17 pages 0.46 mb -
Power Supply
American Power Conversion 650
2 pages 0.4 mb -
Power Supply
American Power Conversion AP7602
24 pages 0.58 mb -
Power Supply
American Power Conversion 110, 120, 230
16 pages 0.16 mb -
Power Supply
American Power Conversion 100VAC
18 pages 0.93 mb -
Power Supply
American Power Conversion 208 VAC
19 pages 1.02 mb -
Power Supply
American Power Conversion SYMSTRF
75 pages 5.52 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion CTFLP Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion CTFLP Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion CTFLP Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion CTFLP Series should contain:
- informations concerning technical data of American Power Conversion CTFLP Series
- name of the manufacturer and a year of construction of the American Power Conversion CTFLP Series item
- rules of operation, control and maintenance of the American Power Conversion CTFLP Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion CTFLP Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion CTFLP Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion CTFLP Series.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion CTFLP Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
990-5519 02/2003 BroadBand CTFLP Series Uninterruptible Power Supply User’s Manual[...]
-
Page 2
[...]
-
Page 3
1 Chapter 1 General Information The CTFLP Se ries provides a n uninterru ptible powe r source for broadband cabl e operations. T he enclosure is designed for mounting on either a pol e or wall. Safety This Safety Guide contains important instructio ns that s hould be foll owed duri ng installa tion and maintenance of the APC equipment an d batterie[...]
-
Page 4
2 Specifications Environmental Specifications Operating Temperature -40º F to 158º F (-4 0º C to 70º C) Humidity 5% to 95% n oncondensing w ithin enclosure Physical Specifi cations Characteristic Specification Height X Width X Dept h 11.4” X 8 .5” X 7.1” ( 29 cm X 22 cm X 18 cm ) Weight 36 lbs (16 kg) Electrical Specifications Input Chara[...]
-
Page 5
3 Chapter 2 Installation and Maintenance Only trained service personnel should install and maintain th e Power Supply. Prior to installing the Power Supply utility li ne voltage must be routed to the enclosure. Local, state, federal and/ or National Elect ric Code (NEC) regulations regarding l ocation, perm its and electrical wiring must be adhered[...]
-
Page 6
4 CTFLP Enclosure Installation Loosen (do not remove), t he four .25” (. 63 cm) nut s on the bracket assembly. Wall Mount Units: Select fasteners that will accommodate the wei ght of the unit including the power sup ply. Wiring 1. Attach conduit to th e 1/2 “ hole on the bottom of the unit an d wire the input line. INDEX ITEM DESCRIPTION 1 60/9[...]
-
Page 7
5 2. Refer t o the diagram below for wiri ng detail s. • Connect the black and wh ite wires from the incoming utility line. • Route the power feed COAX to the bottom of the enclosure and a ttach t o the COAX cable adapter using a pin connector. • Attach the stinger lug to th e pin connector center pin. • Attach suitable so lid copper ground[...]
-
Page 8
6 Installing the FLM Power Supply Ensure the CTFLP module circuit breaker is OFF. 1. Unlock and open the fron t enclosure door. To remove the fr ont door from the enclosure, squeeze the ed ges of the enclosure together. Th is will allow the pins at the top of the door to slip out of the side enclosure pa nels. 2. The top door of the enclos ure is h[...]
-
Page 9
7 INDEX ITEM DESCRIPTION 1 Front Door Front door of FLP enclosure 2 Option Plug Provides an interface for standard APC power supply options 3 FLM Module Ferroresonant Module- provides output power , 60/90 VAC 4 FLM Circuit Breaker Provides power to FLM 5 Voltmeter (Option) Displays output voltage 6 Utility Auxiliary Plug Provides access to utility [...]
-
Page 10
8 Chapter 3 Operation Initial Startup and Performance Verification 1. Switch the utility circuit breaker ON. 2. Verify that the FLM is switched ON. 3. Measure the voltage at the C oax connector ensuring that 60 VAC or 90VAC are present depending on the power s upply install ed. The green I ndicator lam p on the bott om of the uni t should be illumi[...]
-
Page 11
9 Chapter 4 Troubleshooting and Maintenance Troubleshooting Power Supply Failure Problem Possible Cause Solution No input voltage detected at connector J1, pins 1 and 2. Replace the wiring harness Input volta ge present at co nnector J1, pins 1 and 2. Disconnect power from the supply No input voltage at the black and white wires input lines. Replac[...]
-
Page 12
10 Routine Maintenance Proc edures • Visual Inspection • Check external surfaces, connectors, indicator s a nd wiring/cable assemblies for signs of dirt, wear, and dam age. • Cleaning • Brush dust f rom controls a nd receptacles usi ng a small paintbr ush. • Wipe surfaces with clean, dry cheesecloth. • Clean exterior surface with cl ean[...]
-
Page 13
11 • Replace the quick disconnects on the indicator lam p socket. • Reconnect the utility wires and the sting er lug. • Close the front door of the enclosure. • Reinstall the F LM. Ensure the m odule is seated p roperly. R efer to Installing the FLM in this manual. • Switch the FLM and the utility circuit breakers ON. • Complete Perform[...]
-
Page 14
12 Chapter 5 Service, Con tact and Warranty Information Service APC makes every effort to ensure parts and equipment arrive in working condition. Occasionally, it may be necessary to return parts or equi pment that are not i n working condition. If the UPS requires service do not return it to the dealer. Instead, follow t hese steps: 1. Contact APC[...]
-
Page 15
13 Limited Warranty American Power Conversion (APC) warrants its products to be fr ee from defects in mater ials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under wa rr anty you mus[...]