Power Supply
American Power Conversion SL 300TFX
27 pages 0.73 mb -
Power Supply
American Power Conversion 350, 500, 700
2 pages 0.46 mb -
Power Supply
American Power Conversion SURT15000
32 pages 1.95 mb -
Power Supply
American Power Conversion 250VA
16 pages 0.42 mb -
Power Supply
American Power Conversion Redundant Switch
34 pages 0.47 mb -
Power Supply
American Power Conversion HI600SQ
9 pages 0.53 mb -
Power Supply
American Power Conversion HT1000
2 pages 0.51 mb -
Power Supply
American Power Conversion AP9621
17 pages 1.1 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion PDU, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion PDU one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion PDU. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion PDU should contain:
- informations concerning technical data of American Power Conversion PDU
- name of the manufacturer and a year of construction of the American Power Conversion PDU item
- rules of operation, control and maintenance of the American Power Conversion PDU item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion PDU alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion PDU, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion PDU.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion PDU item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PDU Branch Curr ent Monitoring Boar d Installation and Configuration Inventor y Safety Mounting the boar d in the PDU The branch current monitoring board mounts to brackets in the PDU on the right and left side of each circuit breaker panel. The illustration in step 2 on page 2 shows the mounting brackets on the upper right-hand side of th e PDU ci[...]
-
Page 2
Installation and Configuration 2 Branch Current Monitoring Kit Installat ion How to mount the board in the PDU. 1. Insert the three socket-head screws into the board and attach the retainers to the screws. 2. Attach the board to any of the four sets of mounting brackets inside the PDU. Note The front of the board must face away from the PDU. 3. Sec[...]
-
Page 3
Installation and Configu ration Branch Current Monitoring Kit 3 How to ro ute power cable wires. 1. Route the phase conductor throu gh a current sensor . If it is a three-phase cable, route each of the L1, L2, and L3 wires through its own cu rrent sensor . 2. Connect the L1, L2, and L3 wires to single-pol e breakers or to a three-pole breaker . (Th[...]
-
Page 4
Installation and Configuration 4 Branch Current Monitoring Kit How to connect the board to the monitoring unit. 1. Plug one end of the mon itoring cable i nto the port on the board. 2. Plug the other end of the cable into a port on the PDU monitoring unit. Note If the board is on the left side of the PD U, the port will be on the bottom of the boar[...]
-
Page 5
Installation and Configu ration Branch Current Monitoring Kit 5 Configuration Configure the branch current m onitoring parameters using either the Panel configuration option or Global panel config option on the Panel screen of the PDU display interface. Panel Config. Configure the branch metering settings for each circuit breaker on the distributio[...]
-
Page 6
Installation and Configuration 6 Branch Current Monitoring Kit Global Panel Config. Configures the same number of poles or circuit breaker ratings for all circuit breakers in both distribution panels simultaneously . For example, if your syst em uses only three-pole, 20-amp circuit breakers, choose this option, scroll to t he value 3 for Poles and [...]
-
Page 7
[...]
-
Page 8
*990-1646A* APC W orldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • V isit the APC W eb site to access documents in the APC Knowledge Base and to submit customer support requests. – www .apc.com (Corporate Headquarters) Connect to localized APC W eb sites for s[...]