A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion SYTF3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion SYTF3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion SYTF3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of American Power Conversion SYTF3 should contain:
- informations concerning technical data of American Power Conversion SYTF3
- name of the manufacturer and a year of construction of the American Power Conversion SYTF3 item
- rules of operation, control and maintenance of the American Power Conversion SYTF3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion SYTF3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion SYTF3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion SYTF3.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion SYTF3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    990-7820D, July 2003 APC S tep-Down T ransformer Models: AP9621, SUR T005, SUR T006, SUTF3, SYTF2, SYTF2J, SYTF3 and SYTF3J User ’ s Manual English[...]

  • Page 2

    [...]

  • Page 3

    T ABLE OF C ONTENT S APC Contact Numbers and Support Visit the APC Web site for contact numbers and support at http://www.apc.com/suppor t . Chapter 1: Safety and General Information ................................................................. 1 Save These Instructions ...........................................................................[...]

  • Page 4

    T ABLE OF C ONTENT S[...]

  • Page 5

    C HAPTER 1: S AFETY AND G ENERAL I NFORMA TION 1 Save These Instructions Conventions Used in this Manual The WARNING sign denotes a serious haza rd. It calls attention to a procedure, practice, condition, or the like, which, if not correctly performed or adhered to, could result in injury to personnel. The CAUTION sign denotes a hazard. It calls at[...]

  • Page 6

    C HAPTER 1: S AFETY AND G ENERAL I NFORMA TION 2 De-energizing Safety To de-energize this equipme nt toggle the rear input circuit breaker to the OFF position, an d then disconnect the equipment from the AC po wer outlet. Electrical Safety • The protective earth conductor carries the leakag e current from the load devices (comput er equipment). T[...]

  • Page 7

    C HAPTER 1: S AFETY AND G ENERAL I NFORMA TION 3 Life Support Policy Limited W arrant y Copyright and T r ademark Information As a general policy, American Power Conversion (APC) does not recomme nd the use of any of its products in life support applications where failure or malfunction of the APC product can be re asonably expected to cause failur[...]

  • Page 8

    C HAPTER 1: S AFETY AND G ENERAL I NFORMA TION 4[...]

  • Page 9

    C HAPTER 3: I NST ALLA TION 5 About Y our Step-Down T ransformer Table 1: System Configurations and Model Number s * Power cord connected units have an available p ower of 4500 VA with a L6-30 plug. ** Units with an available po wer of 5000 VA must be hardwired du e to input current. *** Ensure that the pin number for T- slot receptacles is correct[...]

  • Page 10

    C HAPTER 3: I NST ALLA TION 6 Product Overview[...]

  • Page 11

    C HAPTER 3: I NST ALLA TION 7 Front View Component Identification Figure 2: AP9621 Figure 3: SUTF3 / SYT F2 / SYTF2J / SYTF3 / SYTF3J Figure 4: SURT005/ SURT006 Rear View Component Identification Figure 5: AP9621 / SYTF2 / SYTF2J / SURT005 / SURT006 Figure 6: SUTF3 / SYTF3 / SYTF3J Rail Cleats  : Two cleats (one on each side) of the Step-Down Tr[...]

  • Page 12

    C HAPTER 3: I NST ALLA TION 8 Unp acking Inspection Contents Inst alling the S tep-Down T ransformer Installing in a Four-Post Rack Figure 8: AP9621 / SURT005 / SURT006 Figure 9: SUTF3 / SYTF2 / SYTF2J / SYTF3 / SYTF3J 1. Install the mounting rails using the instructions contai ned in the Rail Kit. 2. Slide the Step-Down Transfor mer frame into the[...]

  • Page 13

    C HAPTER 3: I NST ALLA TION 9 Wiring the Step-Down Transformer 1. For cord connected installations, plug the inp ut power cord  into the outlet  . 2. For hardwired installations: • Verify that all branch circuit (mains) are de-energized an d locked out before installing cables or making connections. • Wiring by a licensed electricia n is [...]

  • Page 14

    C HAPTER 3: I NST ALLA TION 10 Connecting Load Equipment Plug all load equipment int o PDU  receptacles. • For AP9621, SYTF2, SYTF2J, SURT 005, and SURT006 models, the receptacles are divided into 4 gr oups; each group is protected by a 15-am p circuit breaker. A colored label identifies each circuit and its circuit bre aker. • For SUTF3, SY[...]

  • Page 15

    C HAPTER 3: I NST ALLA TION 11 Using the Step-Down Transformer • Connect the Step-Down Transformer to a UPS for continuous po wer during a utility power failure. • The transformer has an efficiency of 90%. This requires 550 0 VA for a 5000 VA load, 5000 VA for a 4500 VA load, and 3900 VA for a 3500 VA load. Be careful not to overload your bra n[...]

  • Page 16

    C HAPTER 4: S PECIF ICA TIONS 12 Product S pecifications Electrical Specifications AP9621 / SUTF3 / SYTF2 / SYTF3 / SURT005 SYTF2J / SYTF3J / SURT006 Nominal Input Voltage (VAC) 208 200 Input Voltage Range (VAC) 185 to 230* 180 to 220 Maximum Input Current (amps) Line cord Installation (L6-30) Hardwire Installation 24 26** 22 Line Frequency (Hz) 60[...]

  • Page 17

    C HAPTER 4: S PECIF ICA TIONS 13 Other Specifications Dimensions (H x W x D) (Overall) 3.5 in x 19 in x 26 in ( with bezel) (8.9 cm x 48.3 cm x 66 cm) Weight Net Shipping 95 lbs (43kg) 110 lbs (50 kg) Temperature Operating Storage 0 to 40 ° C –25 to 65 ° C Humidity, relative Operating and storage 5 to 95% Elevation Operating Storage 0 to +3,000[...]