Go to page of
Similar user manuals
-
Power Supply
American Power Conversion PDRPPNX10
80 pages 1.87 mb -
Power Supply
American Power Conversion RS/XS 1500
2 pages 0.46 mb -
Power Supply
American Power Conversion 350/500
2 pages 0.29 mb -
Power Supply
American Power Conversion CTSLP/G
14 pages 0.42 mb -
Power Supply
American Power Conversion 200-240 VAC
21 pages 0.45 mb -
Power Supply
American Power Conversion ES 550
2 pages 0.28 mb -
Power Supply
American Power Conversion SUDP6000I
24 pages 0.81 mb -
Power Supply
American Power Conversion XS 450 -48
48 pages 2.58 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Power Conversion VA1500, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Power Conversion VA1500 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Power Conversion VA1500. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Power Conversion VA1500 should contain:
- informations concerning technical data of American Power Conversion VA1500
- name of the manufacturer and a year of construction of the American Power Conversion VA1500 item
- rules of operation, control and maintenance of the American Power Conversion VA1500 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Power Conversion VA1500 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Power Conversion VA1500, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Power Conversion service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Power Conversion VA1500.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Power Conversion VA1500 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
990 - 1851 C, 10 /2005 User Manual English APC Smart - UPS ® SC 1000/1500 VA 110/120/230 Vac 2U Tower/Rack - Mount Uninterruptible Power Supply[...]
-
Page 2
[...]
-
Page 3
1 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brow n outs, sags, and surges from reaching your equipment. The uninterruptible power supply (UPS) filters small uti l- ity line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line. The UPS provi[...]
-
Page 4
2 Tower Configuration Note: Illustrations in this document may appear different than the actual h ardware. Œ • Ž • Mount the UPS in a Two - Post Rack Œ • Remove battery bracket screws, battery bracket, and ba t tery.[...]
-
Page 5
3 Ž • Note: For information on the four - post rack - mounting kit, see www.apc.com . • Reinstall battery, battery bracket, and screws. ‘[...]
-
Page 6
4 2: S TART UP Connect Equipment to the UPS Rear Panels 110/120 V: 230 V: • Note: A laser printer draws significantly more power than other types of equipment and may ove r load the UPS. Connect t he UPS to the Network (if Applicable) Network Connectors Serial Port Modem/Telephone/Fax Ports Network Surge Suppre s sion Ports Use only interface kit[...]
-
Page 7
5 Start the UPS 1. Plug the UPS into a two - pole, three - wire, grounded receptacle only. Avoid using exte n sion cords. 110/120 V models : The power cord is attached to the UPS. The input plug is a NEMA 5 - 15P. 230 V models: The power cord is supplied in the UPS literature kit. 2. 110/120 V models : Check the site wiring fault LED located on the[...]
-
Page 8
6 3: O PERATION Front Display Panel 110/120 V 230 V I NDICATOR D ESCRIPTION On L ine The UPS is supplying utility power to the connected equipment. On Ba t te ry The UPS is supplying battery power to the connected equipment. Ove r load The connected loads are drawing more than the UPS power rating. Replace Ba t tery/ Battery Disco n nected The batt[...]
-
Page 9
7 4: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE ADJUSTED THROUGH P OWER C HUTE S OFTWARE F UNCTION F ACTORY D E FAULT U SER S E LECTABLE C HOICES D ESCRIPTION Self - Test Every 14 days (336 hours) Every 7 days (168 hours), Every 14 days (336 hours), On Startup Only, No Self - Test Set the inte r val at which the UPS will execute a self - test[...]
-
Page 10
8 N OTE : S ETTINGS ARE ADJUSTED THROUGH P OWER C HUTE S OFTWARE F UNCTION F ACTORY D E FAULT U SER S E LECTABLE C HOICES D ESCRIPTION Low Battery War n ing 2 minutes PowerChute B usiness Edition sof t ware provides automatic, una t- tended shutdown when approx i- mately 2 mi n utes of battery ope r- ated runtime r e- mains. 2, 5, 7, 10 mi n utes ([...]
-
Page 11
9 5: S TORAGE AND M AINTENANCE Storage Store the UPS covered in a cool, dry location, with th e ba t tery fully charged. At - 15 to +30 ° C (+5 to +86 ° F), charge the UPS ba t tery every six months. At +30 to +45 ° C (+86 to +113 ° F), charge the UPS ba t tery every three months. Battery Replacement The UPS battery life differs based on usage [...]
-
Page 12
10 6: T ROUBLESHOOTING , S HIPPING , AND S ERVICE Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.com with co m plex UPS problems. P ROBLEM AND / OR P OSSIBLE C AUSE S OLUTION UPS WILL NOT TURN ON UPS not connected to utility power supply. Check that the power cord from the UPS to the utility p ower supp[...]
-
Page 13
11 P ROBLEM AND / OR P OSSIBLE C AUSE S OLUTION THE OVERLOAD LED IS ILLUMINATED AND THE UPS EMITS A SU S TAINED ALARM TONE The UPS is overloaded. The connected equipment is dra w- in g more VA than the UPS can sustain. The connected equipment exceeds the specified “maximum load.” The alarm remains on until the overload is removed. Disconnect no[...]
-
Page 14
12 Shipping and Service Prepare the UPS for shipping: Shutdown and disconnect any equipment attached to the UPS. Shut down th e UPS, and di s connect the UPS from the utility power outlet. Disconnect the battery. If the UPS requires service do not return it to the dealer. Follow these steps: 1. Review the problems discussed in Troubleshooting to el[...]
-
Page 15
13 7: R EGULATORY AND W ARRANTY I NFORMATION 110/120 V models This equipment has been tested and found to comply with the limits for a Class A digital device, pu r- suant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is opera ted in a commercial enviro n ment.[...]
-
Page 16
14 Limited Warranty American Power Conversion (APC) warrants its produc ts to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole o p tion, any such defective products. To obtain service und er warranty you mus[...]