Go to page of
Similar user manuals
-
Plumbing Product
American Standard 2455
4 pages 0.14 mb -
Plumbing Product
American Standard T430.50X
3 pages 0.18 mb -
Plumbing Product
American Standard 4175.1
3 pages 0.38 mb -
Plumbing Product
American Standard 6542.175
2 pages 0.12 mb -
Plumbing Product
American Standard 7015.017)
1 pages 0.15 mb -
Plumbing Product
American Standard 9011.100.365
1 pages 0.12 mb -
Plumbing Product
American Standard 2792
5 pages 0.28 mb -
Plumbing Product
American Standard TOWNSQUARE T555.500
3 pages 9.01 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Standard 6068.22X, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Standard 6068.22X one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Standard 6068.22X. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Standard 6068.22X should contain:
- informations concerning technical data of American Standard 6068.22X
- name of the manufacturer and a year of construction of the American Standard 6068.22X item
- rules of operation, control and maintenance of the American Standard 6068.22X item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Standard 6068.22X alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Standard 6068.22X, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Standard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Standard 6068.22X.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Standard 6068.22X item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Installation Instr uctions Installation Instr uctions (In T oronto Area onl y: 1 -905-3061 093) Certified to comply with ASME A112.19.2M © 20 1 0 AS America, Inc. NO TE T O INST ALLER: Please giv e this manual to the cust omer af ter installation. SELECTRONIC™ PROXIMITY TOILET CONCEALED FLUSH V AL VE 1.28 & 1.6 GPF Concealed Flushometer for[...]
-
Page 2
All American Standar d Products Are W ater T ested At Our Factory . Some Residual Wat er May R emain In The V alve Dur ing Shipping. T hank you for selecting American-Standar d...the benchmark of f ine qualit y f or over 1 00 years. T o ensure that your installation pr oceeds smoothly --please read these instructions c arefully bef ore you begin. U[...]
-
Page 3
RECOMMENDED T OOLS; F ig. 2 F ig. 2 1. 2. 3. 4. 5. 6. 7. 8. 9. 10 . T eflon T ape Flat Blade Scre wdriver Adjust able W rench T ape Measure Hacksa w T ubing Cutt er File F or Sweat C onnection; Solder and T orch 2.5mm He x W rench 1 .5mm He x W rench 1 2 3 4 5 6 79 1 0 8 PRIOR T O INS T ALLA TION Note: Pr ior to installing the Selectr onic™Flush [...]
-
Page 4
F ig. 4 Fig. 3a F ig. 5 3 INS T ALL ELECTRIC AL BO X A SSEMBL Y ; F ig. 3 1. Cut a 1 27x1 27mm (5"x 5") opening in finished wall f or ELECTRIC AL BO X (1) at the deminsion shown in F ig.3. 2. Rot ate the 4 MOUNTING T ABS (2) flat against the electrical bo x. Holding the MOUNTING T ABS (2) in position install the ELECTRIC AL BO X (1) into [...]
-
Page 5
4 F ig. 6 F ig. 6a F ig. 6b F ig. 6c 3 4 INS T ALL V A CUUM BREAKER AND FLUSH CONNECTIONS; Fig. 6 4 1. Place the SPUD FLANGE (1) over the spud on the F ixture . Fig. 6. 2. Thread SPUD COUPLING NUT (2) ont o Spud. Make sure SEAL W ASHER (4) and FRICTION W ASHER (3) are inst alled. Do not tighten full y . Fig. 6. 3 . R emove the COUPLING NUTS (6, 6a)[...]
-
Page 6
7 9 6 2 5 8 10 F ig. 9 F ig. 8 5 7 1. Inser t the side ADJUS T ABLE T AILPIECE (1) on the FLUSH V AL VE (2) int o the SUPPL Y ST OP (3) . Lubricate the T AILPIECE O-RING (4) with w ater if necessar y . Lightly tighten COUPLING NUT (5) . F ig. 8. Important: Do not use lubricants (other than w ater) or any type of thread sealing past e or tape . INS [...]
-
Page 7
11 6 1. Remo ve the f our CO VER SCREWS (1) and CO VER from (2) ELECTRIC AL BO X (4) . F ig. 1 0. 2. P ull the CIRCUIT BO ARD (3) out from ELECTRIC AL BO X (4). Fig. 1 0. 3. Knock out lo wer blank in ELECTRIC AL BO X (4) with flat blade sc rewdr ive r . Install from the back of ELECTRIC AL BO X (4) the PO WER SUPPL Y GROMMET (8) . Fig. 1 0a. 4. Att[...]
-
Page 8
TOP 1. Remo ve the f our CO VER SCREWS (1) and CO VER (2) from ELECTRIC AL BO X (3) . F ig. 1 0. 2. Install BA TTER Y (4) into holder on DC cir cuit board. P ress BA TTER Y (4) down (contacts f acing down ward) in to position until tabs loc k BA TTER Y (4) into place . 3. Att ach the S AFETY CHAIN (5) from the FR ONT P ANEL (6) to the MOUNTING POST[...]
-
Page 9
8 1 4 2 5 5 6 BLUE HOSE BLACK HOSE 1. P ush the BLACK HOSE (1) int o the BO TTOM HOSE CONNECT OR (2) and the other end into the back of the O VERRIDE SWITCH (3) . 2. P ush the BLUE HOSE (4) into the TOP HOSE CONNECT OR (5) on the valv e and the other end into the BO TT OM CONNECTOR (6) on the O VERRIDE SWITCH (3) . CONNECT O VERRIDE HOSES, A C &[...]
-
Page 10
FOR A C-VERSION (MUL TI HOOK-UP); F ig. 1 5, 1 5a Unit #1 Unit #1 Unit #2 Unit #3 1 . Remo ve the CO VER SCREWS (1) and CO VER (2) from each ELECTRIC AL BO X (3) . 2. See AC V ersion Electrical Hook-up f or Unit #1 of the Multi hook-up . 3. Install SENSOR WIRE GROMMET (4) and FLUSH V AL VE SENSOR WIRE (5) into the CO VER (2) of each unit. Inser t t[...]
-
Page 11
3 5 7 6 TOP 1. R emov e FRONT P ANEL. For remo ving front panel see Step 9 f or instr uctions . 2. Remo ve the f our CO VER SCREWS (1) and CO VER (2) from ELECTRIC AL BO X (3) . F ig. 1 6. 3. Disconnect GREY SENSOR WIRE (4) from CIRCUIT BOARD (5) . 4. Remo ve CIRCUI T BOARD (5) from ELECTRIC AL BO X (3) . F ig. 16a. 5. With y our thumbs, spr ead th[...]
-
Page 12
6 TOP 11 Note: T he detection distance is pr eset and is ideal for most installations . Should an adjustment be requir ed f ollow the steps below . 1. Remo ve FR ONT P ANEL (1) . Se e Step 9 for remo ving front panel instr uctions . 2. Remo ve the f our CO VER SCREWS (2) and CO VER (3) from ELECTRIC AL BO X (4) . F ig. 1 8. 3. Disconnect GREY SENSO[...]
-
Page 13
12 IS ST OP V AL VE OPEN? L OOK FOR REPEA TED DOUBLE FLASH ON SENSOR YES INST ALL NEW B A TTER Y TR Y MANU AL V AL VE BUTT ON; WILL THE UNIT FLUSH? NO REPLA CE PIST ON KIT INST ALL NEW B A TTER Y or PLUG-IN A C POWER SUPPL Y SEE STEP 1 3, page 1 0 in manual NO REPLA CE SENSOR NO YES NO NO YES YES OPEN V AL VE UNIT WILL ONL Y FLUSH MANU ALL Y L OOK [...]
-
Page 14
SELECTRONIC™ PROXIMITY TOILET CONCEALED FLUSH V AL VE 1.28 & 1.6 GPF 13 A950223-0071600A SENSOR FOR FLUSH V ALVE WITH 1.6 gpf A950223-0071280A SENSOR FOR FLUSH V ALVE WITH 1.28 gpf A923654-0070A BA TTERY 6VCR-P2 M962664-0070A SOLENOID ASSEMBL Y M962663-0070A PISTON ASSEMBL Y M962752-0020A SLIP JOINT COUPLING M962752-0020A SLIP JOINT COUPLING [...]