American Standard Ceratherm T050.541 manual

1
2
3
4
5
6
7
8
9
10

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of American Standard Ceratherm T050.541, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Standard Ceratherm T050.541 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of American Standard Ceratherm T050.541. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of American Standard Ceratherm T050.541 should contain:
- informations concerning technical data of American Standard Ceratherm T050.541
- name of the manufacturer and a year of construction of the American Standard Ceratherm T050.541 item
- rules of operation, control and maintenance of the American Standard Ceratherm T050.541 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Standard Ceratherm T050.541 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Standard Ceratherm T050.541, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Standard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Standard Ceratherm T050.541.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the American Standard Ceratherm T050.541 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    4" 9-1/2" 6 T050 . 5 4 1 Installation Instructions M968419 REV 1.1 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. Certified to comply with ANSI A112.18.1M ASSE 1016 ROUGHING-IN DIMEN[...]

  • Page 2

    TOP 1 Remove PLASTER GUARD (1). Remove HANDLE SCREW and ADAPTER (7) from rough valve. 1 Push CAPS (2 & 3) as shown onto CONTROL VALVES (4). TRIM INSTALLATION Push ESCUTCHEON (5) onto CAPS (2 & 3) and attach with (60mm) SCREWS (6) to valve. Push COVER PLATE (7) onto CAPS (2 & 3) and snap into holes in ESCUTCHEON (5) to secure. 4 3 2 7 5 [...]

  • Page 3

    O F F O N 3 4 4 4 TEMPERATURE ADJUSTMENT SET HOT LIMIT STOP Check that arrow marking B points to the 3 o'clock position. If not, push the BLACK CLAMP on the SECURING RING to the right, pull off KNOB MOUNT (4) and reinstall KNOB MOUNT (4) with arrow "B" 3 o'clock position. See Figure 1. For 100 F adjustment, turn the water supply[...]

  • Page 4

    A908593-YYY0A VOLUME CONTROL HANDLE 918428-0070A VOLUME HANDLE SCREW A954049-YYY0A VOLUME HANDLE CAP A954043-YYY0A TEMPERATURE HANDLE CAP 918416-0070A TEMPERATURE HANDLE SCREW M961112-YYY0A TEMPERATURE CONTROL HANDLE 918434-YYY0A ESCUTCHEON SCREWS MODEL NUMBER CHROME POLISHED BRASS SATIN 002 099 295 Replace the "YYY" with appropriate fini[...]

  • Page 5

    CENTRAL THERMOST A T WITH VOLUME CONTROL Installation Instructions M968255Rev.1.1 R520 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. T o ensure that your installation pr oceeds smoothly--please read these instructions car efully before you begin. Cer tified to comply with ANSI A112.18.1M ASSE 1016 R[...]

  • Page 6

    M968255Rev.1.1 TEMPERA TURE ADJUSTMENT 2 WARNING Prepare water supplies per ROUGHING-IN DIMENSIONS. Make sure the finished wall is between the minimum and maximum rough dimension. 1 ROUGHING-IN THE VAL VE Install V AL VE at indicated height and depth. Make sure the "TOP" marking on the PLASTER GUARD is up. Connect the hot and cold water [...]

  • Page 7

    CENTRAL THERMOST A T WITH VOLUME CONTROL M968255Rev.1.1 MODEL NUMBER R520 HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1-800 442-1902 W eekdays 8:00 a.m. to 8:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) W eekdays 8:00 a.m. to 7:00 p.m. EST Product names listed herein are trademarks of American S[...]

  • Page 8

    T OP T O P 3/4" CENTRAL THERMOST A T WITH VOLUME CONTROL 3/4" CENTRAL THERMOST A T WITH VOLUME CONTROL Installation Instructions M968480 R540 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. T o ensure that your installation pr oceeds smoothly--please read these instructions car efully before [...]

  • Page 9

    T O P T O P 3/4" CENTRAL THERMOST A T WITH VOLUME CONTROL 3/4" CENTRAL THERMOST A T WITH VOLUME CONTROL Installation Instructions M968480 R540 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. T o ensure that your installation pr oceeds smoothly--please read these instructions car efully before[...]

  • Page 10

    T O P T O P 3/4" CENTRAL THERMOST A T WITH VOLUME CONTROL 3/4" CENTRAL THERMOST A T WITH VOLUME CONTROL Installation Instructions M968480 R540 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. T o ensure that your installation pr oceeds smoothly--please read these instructions car efully before[...]