Go to page of
Similar user manuals
-
Thermostat
American Standard T555.730
2 pages 0.2 mb -
Thermostat
American Standard Town Square T555730
3 pages 0.28 mb -
Thermostat
American Standard R520
3 pages 0.21 mb -
Thermostat
American Standard 340
24 pages 0.47 mb -
Thermostat
American Standard Copeland T005.730
9 pages 1.89 mb -
Thermostat
American Standard T373.730
2 pages 0.18 mb -
Thermostat
American Standard R540
3 pages 0.64 mb -
Thermostat
American Standard Enfield T37373X
3 pages 8.1 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Standard T373.730, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Standard T373.730 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Standard T373.730. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Standard T373.730 should contain:
- informations concerning technical data of American Standard T373.730
- name of the manufacturer and a year of construction of the American Standard T373.730 item
- rules of operation, control and maintenance of the American Standard T373.730 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Standard T373.730 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Standard T373.730, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Standard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Standard T373.730.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Standard T373.730 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
F25 © 20 08 AS A mer ic a Inc . ENFIELD CENTRAL THERMOST A T LES S VOLUME C ON TROL 242mm (9-5/8) M O D E L N U M B E R : TR I M K IT S : T3 7 3 . 7 32 C e n tr a l T he r m o s ta t T r im K i t Le s s v o l um e co n t ro l . W i t h C r os s ha n d le . L ESS V a lv e . T3 7 3 . 7 30 C e n tr a l T he r m o s ta t T r im K i t Le s s v o l um e[...]
-
Page 2
F26 © 20 08 AS A mer ic a Inc . ENFIELD CENTRAL THERMOST A T LES S VOLUME C ON TROL 242mm (9-5/8) M O D E L N U M B E R : TR I M K IT S : T3 7 3 . 7 32 C e n tr a l T he r m o s ta t T r im K i t Le s s v o l um e co n t ro l . W i t h C r os s ha n d le . L ESS V a lv e . T3 7 3 . 7 30 C e n tr a l T he r m o s ta t T r im K i t Le s s v o l um e[...]