American Water Heater BCG3 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of American Water Heater BCG3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Water Heater BCG3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of American Water Heater BCG3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of American Water Heater BCG3 should contain:
- informations concerning technical data of American Water Heater BCG3
- name of the manufacturer and a year of construction of the American Water Heater BCG3 item
- rules of operation, control and maintenance of the American Water Heater BCG3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Water Heater BCG3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Water Heater BCG3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Water Heater service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Water Heater BCG3.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the American Water Heater BCG3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    COMMERCIAL GAS W A TER HEA TERS Instruction Manual PRINTED 061 2 318819-002 PLACE THESE INSTRUCTIONS ADJACENT TO HEA TER AND NOTIFY OWNER T O KEEP FOR FUTURE REFERENCE.            ?[...]

  • Page 2

    2   17    ?[...]

  • Page 3

    3 SAFE INST ALLA TION, USE AND SERVICE ?[...]

  • Page 4

    4 GENERAL SAFETY INFORMA TION Fire Hazard Do not install water heater on carpeted floo r. Do not operate water heater if flood damaged. For continued protection against risk of fire: Fire or Explosion Hazard Read instruction manual before installing, using or servicing water heater . Av oid all ignition sources if you smell gas. Do not store or use[...]

  • Page 5

    5 PRECAUTIONS                      [...]

  • Page 6

    6            ?[...]

  • Page 7

    7 THE ELIMINA TOR (SELF-CLEANING SYSTEM)                     ?[...]

  • Page 8

    8 ROUGH IN DIMENSIONS RECOVER Y CAP ACITIES GAS AND ELECTRICAL CHARACTERISTICS FRONT VIEW TOP VIEW BACK VIEW F TOP OUTLET 1 1/2” NPT TOP INLET 1 1/2” NPT T ABLE 1. ROUGH-IN-DIMENSIONS     ?[...]

  • Page 9

    9                            [...]

  • Page 10

    10 INSULA TION BLANKET Do not obstruct water heater air intake with insulating blanket. Gas and carbon monoxide detectors are available. Install water heater in accordance with the instruction manual. Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. Breathing Hazard - Carbon Monoxide Gas ?[...]

  • Page 11

    11 Breathing Hazard - Carbon Monoxide Gas Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. Under no circumstances should the input exceed the rate shown on the water heater ’s rating label. Overfiring could result in damage to the water heater and sooting. Gas and carbon monoxide detectors [...]

  • Page 12

    12                        [...]

  • Page 13

    13 HO T WA TER OUTLET TO TA NK INLET CHECK VA LV E MIXING VA LV E COLD WA TER INLET TEMPERED WA TER OUTLET 12” TO 15” (30-38 cm) CHECK VA LV E FIGURE 10. D I SH WAS H I NG M ACH I N ES    ?[...]

  • Page 14

    14                  [...]

  • Page 15

    15             ?[...]

  • Page 16

    16 MUL TIPLE HEA TER MANIFOLD              ?[...]

  • Page 17

    17                   ?[...]

  • Page 18

    18 TYPE B GAS VENT Multiple Gas Fired T ank-T ype Heaters                ?[...]

  • Page 19

    19 MODEL (A)BCG3100T2506NOX Input: 250,000 Btu/hr T otal V ent Height (Feet) V ent Connector Size: 6 inches 6 8 10 15 20 30 50 100 Input Btuh/hr Rise V ent Connector Diameter (Inches)                     ?[...]

  • Page 20

    20 W A TER HEA TER INST ALLA TION T&P V AL VE DISCHARGE PIPE Explosion Hazard Te mperature-Pressure Relief Va lv e must comply with ANSI Z21.22- CS A 4.4 and ASME code. Properly sized temperature- pressure relief valve must be installed in opening provided. Can result in overheating and excessive tank pressure. Can cause serious injury or death[...]

  • Page 21

    21 INST ALLA TION DIAGRAMS - TOP INLET/OUTLET USAGE                  ?[...]

  • Page 22

    22 HEA TER WIRING       ?[...]

  • Page 23

    23 GAS PIPING                  ?[...]

  • Page 24

    24 PRIOR TO ST ART UP                  ?[...]

  • Page 25

    25 CHECKING THE INPUT                 [...]

  • Page 26

    26 SEQUENCE OF OPERA TION            ?[...]

  • Page 27

    27 SEQUENCE OF OPERA TION FLOW CHART   FIGURE 24.[...]

  • Page 28

    28 CHECK THE IG NITER AS SEMBL Y AN D MAI N BURNE RS                [...]

  • Page 29

    29 Explosion Hazard Te       -    ?[...]

  • Page 30

    30 T A NK CLEA NOUT PROCEDUR E                       [...]

  • Page 31

    31             ?[...]

  • Page 32

    32         [...]

  • Page 33

    33                  [...]

  • Page 34

    34 COMPLAINT CAUSE REMEDY USER QUALIFIED SERVICE AGENCY *W ater not hot enough    temperature ?[...]

  • Page 35

    35 W A TER PIPING DIAGRAMS N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi ce v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t r[...]

  • Page 36

    36 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 37

    37 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 38

    38 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 39

    39 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 40

    40 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 41

    41 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 42

    42 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI FLUE (2 UNITS) TWO TEMPERA TURE LEGEND TEMPERA TURE [...]

  • Page 43

    43 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI FL UE (2 UNITS) WITH BOOSTER TWO TEMPERA TURE LEGEND[...]

  • Page 44

    44 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI-FL UE (3 UNITS) LEGEND TEMPERA TURE & PRESSURE R[...]

  • Page 45

    45 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 46

    46 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 47

    47 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI FL UE FLUE (4 UNITS) LEGEND TEMPERA TURE & PRESS[...]

  • Page 48

    48 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 49

    49 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o [...]

  • Page 50

    50 MANIFOLD KITS MANIFOLD KITS TWO UNIT MANIFOLD KIT (P ART NO. 9003426205) THREE UNIT MANIFOLD KIT (P ART NO. 9003427205) FOUR UNIT MANIFOLD KIT (P ART NO. 9003428205) MODEL DIMENSION "A" BCG3 70T12 0 5NOX 63" BCG3 80T150 6NOX 68" BC G3 10 0T 18 0 6N OX 72" BCG3 95T199 6NOX 72" BC G3 10 0T 1 99 6N OX 72" A/BC G3 [...]

  • Page 51

    W ARRANTY Commercial Limited W arranty    ?[...]

  • Page 52

           ?[...]