Amtrol WELL-X-TROL manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Amtrol WELL-X-TROL, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Amtrol WELL-X-TROL one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Amtrol WELL-X-TROL. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Amtrol WELL-X-TROL should contain:
- informations concerning technical data of Amtrol WELL-X-TROL
- name of the manufacturer and a year of construction of the Amtrol WELL-X-TROL item
- rules of operation, control and maintenance of the Amtrol WELL-X-TROL item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Amtrol WELL-X-TROL alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Amtrol WELL-X-TROL, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Amtrol service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Amtrol WELL-X-TROL.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Amtrol WELL-X-TROL item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    WELL-X -TROL PR OFESSIONAL Pr e-Pr essurized W ater System T anks[...]

  • Page 2

    WELL-X-TROL ® Pr ofessional r e v olutionizes the industr y WELL-X -TR OL ® Pr ofessional redefined the industr y with its advanced engineering and innov ative pr oduct design including the pre-pr essurized well tank, sealed-in air char ge, and unique water chamber design. W ith pro ven per formance since 1 963, WELL -X -TROL Pr ofessional contin[...]

  • Page 3

    Advanced design f eatur es continue to set industr y standards ■ Stainless steel air valve is welded in position rather than mechanically threaded to prevent loss of air pressure and to minimize stress on the well’ s pump system. It also carries a tamper-evident warning label. ■ Deep-drawn steel domes offer twice the strength of rolled steel [...]

  • Page 4

    esp (Effective System Pr otection): maximum sy stem output wit h minimal pump star ts The ESP sizing procedure covers modern residential water-use habits, increased of f-peak demands and the general increase in water use that have occurred over the past twenty-five years. ESP sizing is designed to reduce pump wear and tear , and reduce energy consu[...]

  • Page 5

    1 2 3 4 WELL-X -TROL Pr ofessional has a sealed in air chamber that is pr e-pr essurized befor e it leaves our factor y . Air and water do not mix. When t he pum p st ar ts, water ent er s t he WELL-X - TR OL Pr ofessional. Only usable water is stor ed. When the pressur e in the chamber r eac hes cut-out pr essur e, the pump stops. The WELL-X -TROL[...]

  • Page 6

    In-Line Models Stand Models WELL-X-TROL Pr ofessional r esidential models Under gr ound Models Dimensions T otal Max. System Drawdown Shipping Model Diameter Height V olume Accept. 20/40 30/50 40/60 Wt. (V ol.) No. (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft) WX-101 8 12 5/8 2.0 0.45 .8 .7 .6 5 (0.6) WX-102 11 15 4.4 0.55 1.8 1.5 1.3 [...]

  • Page 7

    WELL-X-TROL Pr ofessional specialty r esidential models Pump Stand Models Offset Connector Models Space Saver Model Specialty Options Dimensions T otal Max. System Drawdown Shipping Model Height Width Length V olume Accept. 20/40 30/50 40/60 Wt. (V ol.) No. (ins) (ins) (ins) (gals) Factor (gals) (gals) (gals) lbs (cu ft) WX-105-PS 11 10 9/16 18 1/4[...]

  • Page 8

    Hydr og en Sulf ide R emov al System Arsenic R emoval System Ir on Remov al System W ater Sof tening and Filtr ation Part# 9015-516 MC# 4380 (7/04) © 2004 AMTROL Inc. WELL-X-TROL is a registered trademark of AMTROL Inc. Ask for Quality . Ask for AMTROL ® . ® AMTROL has inno v ativ e w ay s to help you gr ow your business Boiler Expansion T anks [...]