Go to page of
Similar user manuals
-
Fryer
Anetsberger Brothers MX-14AA
28 pages 0.19 mb -
Fryer
Anetsberger Brothers MX-7A
28 pages 0.19 mb -
Fryer
Anetsberger Brothers FFM80
2 pages 0.15 mb -
Fryer
Anetsberger Brothers MX-7E
28 pages 0.19 mb -
Fryer
Anetsberger Brothers MX-14-2E
28 pages 0.19 mb -
Fryer
Anetsberger Brothers 14VFS
20 pages 0.18 mb -
Fryer
Anetsberger Brothers CF14
16 pages 0.54 mb -
Fryer
Anetsberger Brothers 14VF
20 pages 0.18 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Anetsberger Brothers CF14, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Anetsberger Brothers CF14 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Anetsberger Brothers CF14. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Anetsberger Brothers CF14 should contain:
- informations concerning technical data of Anetsberger Brothers CF14
- name of the manufacturer and a year of construction of the Anetsberger Brothers CF14 item
- rules of operation, control and maintenance of the Anetsberger Brothers CF14 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Anetsberger Brothers CF14 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Anetsberger Brothers CF14, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Anetsberger Brothers service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Anetsberger Brothers CF14.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Anetsberger Brothers CF14 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 Anetsber ger Br others, Inc. 180 North Anets Drive • Northbrook, Illinois 60062 • 847-272-0770 • Fax 847-272-1943 For ANETS Factory W arranty Service • 800-837-2638 Installation, User Operation, & Maintenance Manual Keep this Manual in a Convenient Location for Reference W ARNING After installation of this equipment, immediately conta[...]
-
Page 2
2 CONTENTS Shipping Container Inspection ........................................................ 3 Fryer Gas Supply Specifications ..................................................... 3 Fryer Electrical Specifications ....................................................... 4 Figure 1 - Fryer Model CF14 W iring Diagram ....................... 4 Co[...]
-
Page 3
3 1 . Carefully examine the shipping carton for external damage. When damage is noted, notify the delivery carrier immediately . Save all packing materials for damage claim examination. 2. If no external damage is noted, remove the shipping carton from the fryer and examine the SHIPPING CONT SHIPPING CONT SHIPPING CONT SHIPPING CONT SHIPPING CONT A[...]
-
Page 4
4 Figure 1. Fr yer Model CF14 W iring Diag ram Figure 1 is a wiring diagram of an ANETS ANETS ANETS ANETS ANETS CF14 Fryer . Some fryers may have other options that do not appear in this basic wiring diagram. A model-specific wiring diagram included with each fryer shows all the actual parts and their associated wiring connections. FR YER ELECTRICA[...]
-
Page 5
5 Figure 2. F r y er Site Installation R equir ements Install the fryer in accordance with the preceding Code Requirements, as well as the following Installation Requirements. 1. DO NOT install this fryer in a mobile home, trailer , or recreational vehicle. 2. Install this fryer in a location that allows it to be moved away from other adjacent appl[...]
-
Page 6
6 GAS CONNECTION INSTRUCTIONS GAS CONNECTION INSTRUCTIONS GAS CONNECTION INSTRUCTIONS GAS CONNECTION INSTRUCTIONS GAS CONNECTION INSTRUCTIONS Installing your ANETS Fryer requires the fol- lowing procedure, after it is in its desired location. 1. Ensure that the gas control valve knob in the fryer has its OFF position next to the valve mark. 2 . Ens[...]
-
Page 7
7 FR YER PREP AR A TION FOR USE “BOIL OUT” INSTRUCTIONS New ANETS Fryers are leak-tested and cleaned at the factory before shipping. Before using a newly installed fryer for food preparation, clean the kettle again, as follows: 1. Thoroughly wipe the interior of the kettle with clean cloths. Open the front door on the lower portion of the fryer[...]
-
Page 8
8 FR FR FR FR FR YER OPERA YER OPERA YER OPERA YER OPERA YER OPERA TING INSTR TING INSTR TING INSTR TING INSTR TING INSTR UCTIONS UCTIONS UCTIONS UCTIONS UCTIONS (Continued) Figure 6. Gas Contr ol V alve & Knob P ositions OF F PILOT ON Valve Mark OFF P I L O T ON OFF ON P I L O T OFF P I L O T ON OFF PILO T European V alv e Markings ON Valve Ma[...]
-
Page 9
9 NOTE: Shutdown is r ecommended at the end of a workday or whenever no frying is required for a period of several hours. The fryer should be shutdown during any power outage or interruption of gas service. The fryer MUST also be shutdown before draining the kettle, or whenever there is no shortening in the kettle to prevent damage. 1. T urn the th[...]
-
Page 10
10 DAIL Y CLEANING PROCEDURE NOTE: Cleaning is recommended at the end of a workday , to prepare the fryer for proper operation the next time it is to be used. D ANGER DO NOT move the fryer while it contains HOT shortening. Allow it to cool and drain the shortening from the fryer be- fore moving it for service, cleaning, or maintenance to avoid spil[...]
-
Page 11
11 FR FR FR FR FR YER OPERA YER OPERA YER OPERA YER OPERA YER OPERA TING INSTR TING INSTR TING INSTR TING INSTR TING INSTR UCTIONS UCTIONS UCTIONS UCTIONS UCTIONS (Continued) NOTE: Regular maintenance is recommended to keep the fryer operating properly . Once each month, before beginning fryer opera- tion, check the flue (behind the backsplash pane[...]
-
Page 12
12 FR FR FR FR FR YER YER YER YER YER TR TR TR TR TR OUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOO TING GUIDE TING GUIDE TING GUIDE TING GUIDE TING GUIDE (Continued) PROBLEM CA USE REMED Y Pilot flame goes out repeatedly . 1. Low gas supply pressure [less than 6 ” W .C. for natural gas; (1 1 ” W .C. for pro- pane) when all other gas-powered[...]
-
Page 13
13 FR FR FR FR FR YER YER YER YER YER TR TR TR TR TR OUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOO TING GUIDE TING GUIDE TING GUIDE TING GUIDE TING GUIDE (Continued) PROBLEM CA USE REMED Y Main burners do not ignite. 1. Gas control valve knob set to OFF or PILOT . 2. Low gas supply pressure [less than 6 ” W .C. for natural gas; (1 1 ” W .C.[...]
-
Page 14
14 FR FR FR FR FR YER YER YER YER YER TR TR TR TR TR OUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOO TING GUIDE TING GUIDE TING GUIDE TING GUIDE TING GUIDE (Continued) PROBLEM CA USE REMED Y Liquid shortening does not reach the desired temperature for frying. 1. Low gas supply pressure [less than 6 ” W .C. for natural gas; (1 1 ” W .C. for pr[...]
-
Page 15
15 FR FR FR FR FR YER YER YER YER YER TR TR TR TR TR OUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOO OUBLESHOO TING GUIDE TING GUIDE TING GUIDE TING GUIDE TING GUIDE (Continued) PROBLEM CA USE REMED Y Liquid shortening does not reach the desired temperature for frying. (Continued) Recalibrate the thermostat by: (a) removing the cap on the thermostat contro[...]
-
Page 16
16 LIMITED W ARRANTY ANETSBERGER BROTHERS, INC., Northbrook, Illinois, USA, certifies that all equipment of its manufacture is, to the best of its knowledge, free from defective material and workmanship. ANETSBERGER BROTHERS, INC., agrees to replace any integral part of its equipment that proves defective within 15 months of date of original shipme[...]