Go to page of
Similar user manuals
-
Portable Generator
Anritsu 681XXC
241 pages 2.76 mb -
Portable Generator
Anritsu 683XXB
514 pages 4.08 mb -
Portable Generator
Anritsu MU368060A
82 pages 1.26 mb -
Portable Generator
Anritsu MG3681A
4 pages 0.32 mb -
Portable Generator
Anritsu MG3642A
212 pages 1.48 mb -
Portable Generator
Anritsu 682XXB
514 pages 4.08 mb -
Portable Generator
Anritsu MG3690A
16 pages 0.39 mb -
Portable Generator
Anritsu MP1763C
78 pages 1.03 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Anritsu 682XXB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Anritsu 682XXB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Anritsu 682XXB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Anritsu 682XXB should contain:
- informations concerning technical data of Anritsu 682XXB
- name of the manufacturer and a year of construction of the Anritsu 682XXB item
- rules of operation, control and maintenance of the Anritsu 682XXB item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Anritsu 682XXB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Anritsu 682XXB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Anritsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Anritsu 682XXB.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Anritsu 682XXB item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SERIES 682XXB/683XXB SYNTHESIZED SIGNAL GENERA TORS MAINTENANCE MANUAL P/N: 10370-10290 REVISION: H PRINTED: AUGUST 2003 COPYRIGHT 2003 ANRITSU CO. 490 JARVIS DRIVE MORGAN HILL, CA 95037-2809[...]
-
Page 2
W ARRANTY The ANRITSU product(s) listed on the title page is (are) warranted against defects in materials and workmanship for one year from the date of shipment. ANRITSU’ s obligation covers repairing or replacing products which prove to be defective during the warranty period. Buyers shall prepay transportation charges for equipment returned to [...]
-
Page 3
[...]
-
Page 4
[...]
-
Page 5
T able Of Contents Chapter 1 - General Information 1-1 SCOPE OF MANUAL ................. 1-3 1-2 INTRODUCTION ................... 1-3 1-3 DESCRIPTION .................... 1-3 1-4 IDENTIFICA TION NUMBER ............ 1-5 1-5 ELECTRONIC MANUAL ............... 1-6 1-6 RELA TED MANUALS ................ 1-6 Operation Manual ................ 1-6 GPIB Prog[...]
-
Page 6
ALC/AM/Pulse Modulation ............ 2-8 RF Deck ..................... 2-8 Power Supply .................. 2-8 Inputs/Outputs ................. 2-8 Motherboard/Interconnections .......... 2-9 2-3 FREQUENCY SYNTHESIS ............. 2-9 Phase-Lock Loops ................ 2-9 Overall Operation ............... 2-10 RF Outputs 0.01 to 65 GHz ........... 2[...]
-
Page 7
3-7 FREQUENCY SYNTHESIS TESTS ........ 3-1 1 T est Setup ................... 3-1 1 Coarse Loop/YIG Loop T est Procedure ...... 3-12 Fine Loop T est Procedure ............ 3-13 3-8 SPURIOUS SIGNALS TEST : RF OUTPUT SIGNALS £ 2 GHz ( £ 2.2 GHz for 68XX5B MODELS) ..... 3-14 T est Setup ................... 3-14 0.01 - 2 GHz T est Procedure ..........[...]
-
Page 8
3-16 PULSE MODULA TION TEST : RF ON/OFF RA TIO 3-45 T est Setup ................... 3-45 T est Procedure ................. 3-45 3-17 PHASE MODULA TION TESTS ........... 3-48 T est Setup ................... 3-48 F M Input Sensitivity Procedure ......... 3-48 Chapter 4 - Calibration 4-1 INTRODUCTION ................... 4-3 4-2 RECOMMENDED TEST EQUIPM[...]
-
Page 9
4-12 AM CALIBRA TION ................. 4-33 Equipment Setup ................ 4-33 AM Calibration Procedure ........... 4-34 4-13 FM CALIBRA TION ................. 4-37 Equipment Setup ................ 4-37 FM Calibration Procedure ........... 4-38 4-14 PHASE MODULA TION ( F M) CALIBRA TION ... 4-51 Equipment Setup ................ 4-51 F M Calibrat[...]
-
Page 10
6-5 REMOVING AND REPLACING THE A7 PCB ... 6-10 Preliminary .................. 6-10 Procedure ................... 6-10 6-6 REMOVING AND REPLACING THE A8, A9, A10, A1 1, OR A12 PCB .................. 6-10 Preliminary .................. 6-10 Procedure ................... 6-10 6-7 REMOVING AND REPLACING THE A13, A14, OR A15 PCB .................... 6-1[...]
-
Page 11
T able of Contents 1-1 SCOPE OF MANUAL ................. 1-3 1-2 INTRODUCTION ................... 1-3 1-3 DESCRIPTION .................... 1-3 1-4 IDENTIFICA TION NUMBER ............ 1-5 1-5 ELECTRONIC MANUAL ...............1 - 6 1-6 RELA TED MANUALS ................1 - 6 Operation Manual ................1 - 6 GPIB Programming Manual ...........1 -[...]
-
Page 12
Figure 1-1. T ypical Series 682XXB/683XXB Synthesized Signal Generator (Model 68369B Shown)[...]
-
Page 13
Chapter 1 General Information 1-1 SCOPE OF MANUAL This manual provides service information for all models of the Series 682XXB/683XXB Synthesized Signal Generators. The service informa - tion includes replaceable parts information, functional circuit descrip - tions, block diagrams, performance verification tests, and procedures for calibration, tr[...]
-
Page 14
1-4 682XXB/683XXB MM GENERAL 682XXB/683XXB INFORMATION MODELS 68XXXB Model Frequency (GHz) Output Power Output Power w/Step Attenuator 68X37B 2.0 – 20.0 GHz +13.0 dBm +1 1.0 dBm 68X45B 0.5 – 20.0 GHz +13.0 dBm +1 1.0 dBm 68X47B 0.01 – 20.0 GHz +13.0 dBm +1 1.0 dBm 68X53B 2.0 – 20.0 GHz 20.0 – 26.5 GHz +9.0 dBm +6.0 dBm +7.0 dBm +3.5 dBm 6[...]
-
Page 15
1-4 IDENTIFICA TION NUMBER All ANRITSU instruments are assigned a unique six-digit ID number , such as “403002.” The ID number is imprinted on a decal that is af - fixed to the rear panel of the unit. Special-order instrument configura - tions also have an additional special serial number tag attached to the rear panel of the unit. 682XXB/683XX[...]
-
Page 16
When ordering parts or corresponding with ANRITSU Customer Serv - ice, please use the correct serial number with reference to the specific instrument’ s model number (i.e., Model 68347B Synthesized Signal Generator , Serial No. 403002). 1-5 ELECTRONIC MANUAL This manual is available on CD ROM as an Adobe Acrobat Portable Document Format ( * .pdf)[...]
-
Page 17
1-7 OPTIONS The following instrument options are available. Option 1, Rack Mounting . Rack mount kit containing a set of track slides (90 ° tilt capability), mounting ears, and front panel handles for mounting the instrument in a standard 19-inch equipment rack. Option 2A, 1 10 dB Step Attenuator . Adds a 10 dB per step attenuator with a 1 10 dB r[...]
-
Page 18
Option 17A, No Front Panel . Deletes the front panel for use in remote control applications where a front panel display or key - board control are not needed. Option 18, mmW ave Module Bias Output. Provides bias out - put for 54000-xWRxx Millimeter W ave Source Modules. BNC T winax connector , rear panel. Option 19, SCPI Programmability . Adds GPIB[...]
-
Page 19
1-9 PREVENTIVE MAINTENANCE The 682XXB/683XXB must always receive adequate ventilation. A blocked fan filter can cause the instrument to overheat and shut down. Check and clean the rear panel fan honeycomb filter periodically . Clean the fan honeycomb filter more frequently in dusty environ - ments. Clean the filter as follows. Step 1 Remove the fil[...]
-
Page 20
1-10 682XXB/683XXB MM GENERAL STATIC-SENSITIVE COMPONENT INFORMATION HANDLING PRECAUTIONS 1. Do not touch exposed contacts on any static sensitive component. 2. Do not slide static sensitive component across any surface. 3. Do not handle static sensitive components in areas where the floor or work surface covering is capable of generating a static [...]
-
Page 21
1-1 1 ST ARTUP CONFIGURA TIONS The 682XXB/683XXB comes from the factory with a jumper across pins 2 and 3 of front panel connector J12 (Figure 1-4). In this configu - ration, connecting the instrument to line power automatically places it in operate mode (front panel OPERA TE LED on). The startup configuration can be changed so that the signal gene[...]
-
Page 22
1-12 RECOMMENDED TEST EQUIPMENT T able 1-2 provides a list of recommended test equipment needed for the performance verification, calibration, and troubleshooting proce - dures presented in this manual. 1-12 682XXB/683XXB MM INSTRUMENT CRITICAL SPECIFICA TION RECOMMENDED MANUF ACTURER/MODEL USAGE (1) Spectrum Analyzer , with External Mixers and Dip[...]
-
Page 23
682XXB/683XXB MM 1-13 INSTRUMENT CRITICAL SPECIFICA TION RECOMMENDED MANUF ACTURER/MODEL USAGE (1) Modulation Analyzer Frequency Input: 10 MHz (or the IF of the Spectrum Analyzer) AM Depth: 0% to 90% AM Modulation Rates: DC to 100 kHz Filters: 20 kHz lowpass, 300 Hz highpass Hewlett-Packard, Model 8901A P Oscilloscope Bandwidth: DC to 150 MHz V ert[...]
-
Page 24
1-13 EXCHANGE ASSEMBL Y PROGRAM ANRITSU maintains an exchange assembly program for selected 682XXB/683XXB subassemblies and RF components. If a malfunction occurs in one of these subassemblies, the defective unit can be ex- changed. Upon receiving your request, ANRITSU will ship the ex- change subassembly or RF component to you, typically within 24[...]
-
Page 25
682XXB/683XXB MM 1-15 SUBASSEMBL Y OR P ART NAME ANRITSU P ART NUMBER Printed Circuit Board Assemblies Front Panel Assy 683XXB ND40832 Front Panel Assy 682XXB ND40833 A3 Reference Loop PCB Assy D37436-3 A4 Coarse Loop PCB Assy D40604-3 A4 Coarse Loop PCB Assy D40634-3 A5 Fine Loop PCB Assy D37452-3 A5 Fine Loop PCB Assy D40605-3 A5 Fine Loop PCB As[...]
-
Page 26
1-16 682XXB/683XXB MM GENERAL INFORMATION PARTS LIST SUBASSEMBL Y OR P ART NAME ANRITSU P ART NUMBER RF Components YIG-T uned Oscillator , 2 to 20 GHz C27327 Down Converter D27330 Pulsed Digital Down Converter D27370 Switched Doubler Module, 20 to 26.5 GHz ND40843 Switched Doubler Module, 20 to 40 GHz D28535 Source Quadrupler Module, 40 to 50 GHz D[...]
-
Page 27
682XXB/683XXB MM 1-17 GENERAL INFORMATION PARTS LIST SUBASSEMBL Y OR P ART NAME ANRITSU P ART NUMBER Fan Assembly A40513 Fan Mount 790-425 Fan Membrane (Honey Comb Filter) C37137 Fan Grill 790-426 Fasteners (for Fan Grill) 790-433 Fuse, 5A, 3AG Slow Blow (1 10 V ac) 631-33 Fuse, 2.5A, 3AG Slow Blow (230 V ac) 631-14 Gasket, RFI (“O”rings for MC[...]
-
Page 28
1-18 682XXB/683XXB MM UNITED STATES ANRITSU COMPANY 490 Jarvis Drive Morgan Hill, CA 95037-2809 Telephone: (408) 776-8300 1-800-ANRITSU FAX: 408-776-1744 FRANCE ANRITSU S.A 9 Avenue du Quebec Zone de Courtaboeuf 91951 Les Ulis Cedex Telephone: 016-09-21-550 FAX: 016-44-61-065 JAPAN ANRITSU CUSTOMER SERVICE LTD. 1800 Onna Atsugi-shi Kanagawa-Prf. 24[...]
-
Page 29
T able of Contents 2-1 INTRODUCTION ................... 2-3 2-2 682XXB/683XXB MAJOR SUBSYSTEMS ...... 2-3 Digital Control ..................2 - 3 Front Panel ...................2 - 4 Frequency Synthesis ...............2 - 4 Analog Instruction ................2 - 5 YIG Driver ...................2 - 5 Function Generator ...............2 - 5 ALC/AM/Pu[...]
-
Page 30
0.01 to 2 GHz Down Converter ......... 2-24 0.5 to 2.2 GHz Digital Down Converter ..... 2-25 Switched Doubler Module ............ 2-26 Source Quadrupler Module ........... 2-29 Power Level Detection/ALC Loop ........ 2-30 Step Attenuator ................ 2-31 Table of Contents (Continued)[...]
-
Page 31
Chapter 2 Functional Description 2-1 INTRODUCTION This chapter provides brief functional descriptions of the major sub - systems that are contained in each model of the Series 682XXB/ 683XXB Synthesized Signal Generators. In addition, the operation of the frequency synthesis, automatic level control (ALC), and RF deck subsystems is described so tha[...]
-
Page 32
The CPU is indirectly linked via the A16 CPU Inter - face PCB to the A3 Reference Loop PCB, the A4 Coarse Loop PCB, the A5 Fine Loop PCB, and the A6 Pulse Generator PCB. The A16 PCB contains cir - cuitry to perform parallel-to-serial and serial-to- parallel data conversion. It also contains circuitry for many of the rear panel signals, a 13-bit res[...]
-
Page 33
used to fine tune and phase lock the YIG-tuned oscillator . The A1 1 PCB also contains circuitry for frequency modulation of the YIG-tuned os - cillator RF output. The CPU sends control data to the A3 Reference Loop PCB, the A4 Coarse Loop PCB, and the A5 Fine Loop PCB via the A16 PCB as serial data words. The CPU controls the A1 1 FM PCB via the d[...]
-
Page 34
A21-1 BNC / AUX I/0 CONNECTOR PCB AM IN EXT ALC IN DWELL IN AM OUT V/GHz OUT FM OUT SEQ SYNC OUT SERIAL I/O 10 MHz REF IN From RF Deck (Option 9) From A3 Reference Loop To A3 Reference Loop RF OUTPUT Outputs Inputs Power Input 110/220 VAC Line Filter P/O Rear Casting Assy A21 Rear Panel PCB Bridge Rectifier/ Doubler A19 Line Conditioner +165V -165V[...]
-
Page 35
A14 SDM, SQM Driver A9 PIN Control 10 MHz HI-STAB XTAL OSC (Option) 10 MHz REF OUT Real Panel BNC Serial Data 10 MHz REF IN Rear Panel BNC 0.01 - 2 GHz RF Output 0.01 - 40 GHz A3 Reference Loop A4 Coarse Loop A5 Fine Loop A7 YIG Loop 21.5 - 40 MHz Sampled 2 - 20 GHz RF YIG Loop Error Serial Data Serial Data A11 FM Serial Data A13 YIG Driver A12 Ana[...]
-
Page 36
ALC/AM/Pulse Modulation This circuit subsystem consists of the A6 Pulse Gen - erator PCB, the A9 PIN Control PCB, the A10 ALC PCB, and the A14 SDM, SQM Driver PCB. It pro - vides the following: Level control of the RF output power . AM and pulse modulation of the RF output. Current drive signals to the PIN switches lo - cated in the Switched Filter[...]
-
Page 37
inputs are coupled directly via coaxial cables to their destination PCBs—the FM input to A1 1 FM PCB and the Pulse/T rigger input to the A6 Pulse Generator PCB. The rear panel connectors, 10 MHz REF OUT , 10 MHz REF IN , and FM IN , are coupled directly to PCBs via coaxial cables— 10 MHz REF OUT and 10 MHz REF IN to the A3 Reference Loop PCB an[...]
-
Page 38
signal that (depending on polarity) causes the VCO frequency to increase or decrease to reduce any phase difference. When the two inputs match, the loop is said to be locked . The variable input from the VCO then equals the reference input in phase, fre - quency , accuracy , and stability . In practical applications a frequency divider is placed be[...]
-
Page 39
26.84 MHz VCXO Digital Synthesizer Frequency Synthesizer 206 - 391 MHz VCO Fine Loop Oscilator Phase/ Frequency Detector 100 kHz Phase Error Phase Error Phase/ Frequency Detector 9 - 10 MHz Phase Error 10 MHz A5 Fine Loop 100 kHz 9 - 10 MHz 215 - 400 MHz 21.5 - 40 MHz Frequency Divider Phase/ Frequency Detector Coarse Loop Oscillator FM Main Bias P[...]
-
Page 40
output signal sample with the adjacent coarse-loop harmonic produces a low frequency difference signal that is the YIG IF signal (21.5 to 40 MHz). The 682XXB/683XXB CPU programs the coarse-loop oscillator ’ s output frequency so that one of its har - monics will be within 21.5 to 40 MHz of the desired YIG-tuned oscillator ’ s output frequency .[...]
-
Page 41
requiring even greater stability , the 100 MHz refer - ence oscillator can be phase locked to an optional 10 MHz reference (internal or external). RF Outputs 0.01 to 65 GHz Refer to the RF Deck block diagram shown in Fig - ure 2-1 (page 2-7) for the following description. The 682XXB/683XXB uses one 2 to 20 GHz YIG-tuned oscillator . All other frequ[...]
-
Page 42
Frequency Modulation Frequency modulation (FM) of the YIG-tuned oscil - lator RF output is achieved by summing an external or internal modulating signal into the FM control path of the YIG loop. Refer to Figures 2-1 and 2-2. The external modulating signal comes from the front panel or rear panel FM IN input; the internal modulating signal comes fro[...]
-
Page 43
Step Sweep Mode Step (digital) frequency sweeps of the YIG-tuned os - cillator RF output consist of a series of discrete, syn - thesized steps between a start and stop frequency . Each frequency step is generated by applying the tuning signal (from the A12 Analog Instruction PCB) to the YIG-tuned oscillator ’ s main tuning coil, then phase-lockin[...]
-
Page 44
NOTE The instrument uses two internal level de - tection circuits. For frequencies <2 GHz ( £ 2.2 GHz for 682X5B/683X5B models), the level detector is part of the Down Con - verter . The signal from this detector is routed to the A10 ALC PCB as the Detector 0 input. For frequencies ³ 2 GHz (>2.2 GHz for 682X5B/683X5B models), the level de -[...]
-
Page 45
P/O RF Deck Detector 0 Sample/Hold Detector 1 ALC Control Modulator Control Internal AM (From A8 PCB) D0 - D15 L_SEL3 A01 - A03 From CPU Pulse Level Amp Serial Data (From A16 PCB) Detector 1 2 - 20 GHz YIG Oscillator To Step Attenuator or RF Output Detector 0 P/O A9 PCB P/O A6 PCB ALC Modulator Driver Serial/ Parallel Converter Log Amp Sample/Hold [...]
-
Page 46
Power Sweep In this mode, the CPU has the ALC step the RF out - put through a range of levels specified by the user . This feature can be used in conjunction with the sweep mode to produce a set of identical frequency sweeps, each with a different RF power output level. Amplitude Modulation Amplitude modulation (AM) of the RF output signal is accom[...]
-
Page 47
struments to the internally generated pulse; the video pulse is a TTL level copy of the RF output pulse; and the sample/hold signal synchronizes the ALC loop to the ON portion of the pulse modulating waveform. The 682XXB/683XXB has five pulse modulation modes: Internal pulse modulation mode – The pulse modulation waveform is generated and timed i[...]
-
Page 48
RF Deck Con - figurations All 682XXB/683XXB RF deck assemblies contain a 2 to 20 GHz YIG-tuned oscillator , a switched filter as - sembly , and a directional coupler . Beyond that, the configuration of the RF deck assembly varies accord - ing to the particular instrument model. Block dia - grams of the various RF deck configurations are shown in th[...]
-
Page 49
FM MAIN BIAS Modulator Control Switch Control >+17 dBm 500 MHz Down Converter Assy. D27330 8.4-20 GHz 2-8.4 GHz >+4dBm 0.01 - 40 GHz 110 dB Step Attenuator (Option) Directional Coupler Control 3.3 GHz LPF 5.5 GHz LPF 8.4 GHz LPF 13.5 GHz LPF Level Control 6.51 - 8.5 GHz J5 J2 J3 LPF 6.5 GHz J3 J1 Sampler (-20 dBm to -27dBm) J6 J2 Level Contro[...]
-
Page 50
FM MA I N BI AS Mo d u l a t o r Co n t r o l Sw i t c h Co n t r o l >+ 17 dB m 500 M H z Do wn Co n v e r t e r A s s y . D 27330 8. 4- 20 G H z 2- 8. 4 G H z >+4d B m 3. 3 G H z LP F 5. 5 G H z LP F 8. 4 G H z LP F 1 3 .5 G H z L P F Lev el Co n t r o l 6 .5 1 - 8 .5 G H z J5 J2 J3 LP F 6. 5 G H z J3 J1 Sa m p l e r ( - 20 dB m to -2 7 d B[...]
-
Page 51
When the 683XXB is generating broad-band analog frequency sweeps (>100 MHz wide), the main tun - ing coil current tunes the oscillator through the sweep frequency range. Phase locking to fine adjust the oscillator ’ s output frequency is only done at the bottom and top of the sweep ramp and on both sides of each band switch point. Narrow-band [...]
-
Page 52
coupler in the switched filter path of high power switched filter assemblies provides the RF signal for the source quadrupler module (refer to Figure 2-5). Whenever an instrument is generating RF signals of >40 GHz, a RF signal is coupled out via J4 to the source quadrupler module. The switched low-pass filters provide rejection of the harmonics[...]
-
Page 53
amplified, and coupled out for use in internal level - ing. The detected RF sample is routed to the A10 ALC PCB. The 0.01 to 2 GHz RF output from the down con - verter goes to input connector J1 of the switched fil - ter assembly . There, the 0.01 to 2 GHz RF signal is multiplexed into the switched filter ’ s output path. 0.5 to 2.2 GHz Digital D[...]
-
Page 54
ters. PIN switch drive current is generated by inter - nal drivers that are controlled by signals received from the A12 Analog Instruction PCB. The switched low-pass filters provide rejection of unwanted har - monics. The 0.5 to 2.2 GHz RF signal has four filter - ing paths—700 MHz, 1000 MHz, 1400 MHz, and 2200 MHz. After routing through the appr[...]
-
Page 55
FM MAIN BIAS Modulator Control Switch Control >+17 dBm 8.4-20 GHz 2-8.4 GHz >+4dBm 0.5 - 40 GHz 110 dB Step Attenuator (Option) Directional Coupler Control 3.3 GHz LPF 5.5 GHz LPF 8.4 GHz LPF 13.5 GHz LPF J5 J3 J1 Sampler (-20 dBm to -27dBm) J6 J2 Level Control RF Output 2-20 GHz YIG Oscillator Switch Control Bias 20 - 40 GHz >+8.5 dBm Swi[...]
-
Page 56
FM MA I N BI AS Mo d u l a t o r Co n t r o l Sw i t c h Co n t r o l >+ 17 dB m Pu l s e 8. 4- 20 G H z 2- 8. 4 G H z >+4d B m 3. 3 G H z LP F 5. 5 G H z LP F 8. 4 G H z LP F 1 3 .5 G H z L P F Lev el Co n t r o l 2000 - 4400 M H z J5 J3 J3 J1 Sa m p l e r ( - 20 dB m to - 27dB m ) J6 J2 2- 20 G H z Y I G Os c i l l a t o r Sw i t c h Co n t[...]
-
Page 57
RF signal is amplified, then doubled in frequency . From the doubler , the 20 to 40 GHz RF signal is routed by PIN switches to the bandpass filters. There are three bandpass filter paths to provide good harmonic performance. The frequency ranges of the three paths are 20 to 25 GHz, 25 to 32 GHz, and 32 to 40 GHz. After routing through the appropria[...]
-
Page 58
60 GHz RF signal goes via a band-pass filter to the output connector of the SQM. From the SQM, the 40 to 60 GHz RF output signal goes to input connector J1 of the forward coupler , P/N C27184. The other input to the forward coupler at connector J2 is the 0.01 to 40 GHz (0.5 to 40 GHz for 682X5B/683X5B models) RF output signals from the SDM. From fo[...]
-
Page 59
(for 682X5B/683X5B models) to adjust the RF out - put power level. Step Attenuator The optional step attenuator provides up to 1 10 dB (90 dB for 50 GHz and 60 GHz models) attenuation of the RF output in 10 dB steps. The step attenuator drive current is supplied by the A9 PIN Control PCB. 682XXB/683XXB MM 2-31/2-32 FUNCTIONAL RF DECK DESCRIPTION AS[...]
-
Page 60
[...]
-
Page 61
T able of Contents 3-1 INTRODUCTION ................... 3-3 3-2 RECOMMENDED TEST EQUIPMENT .......3 - 3 3-3 TEST RECORDS ...................3 - 3 3-4 CONNECTOR AND KEY LABEL NOT A TION . . . 3-3 3-5 682XXB/683XXB POWER LEVELS .........3 - 6 3-6 INTERNAL TIME BASE AGING RA TE TEST . . . 3-8 T est Setup ....................3 - 9 T est Procedure .....[...]
-
Page 62
3-1 1 POWER LEVEL TESTS ............... 3-26 T est Setup ................... 3-26 Power Level Accuracy T est Procedure ...... 3-27 Power Level Flatness T est Procedure ...... 3-27 3-12 AMPLITUDE MODULA TION TEST ........ 3-30 T est Setup ................... 3-30 AM Input Sensitivity Procedure ......... 3-31 3-13 FREQUENCY MODULA TION TESTS ....... [...]
-
Page 63
Chapter 3 Performance V erification 3-1 INTRODUCTION This chapter contains tests that can be used to verify the performance of the Series 682XXB/683XXB Synthesized Signal Generators to speci - fications. These tests support all instrument models having any ver - sion of firmware. Units with Option 2A, 2B, 2C, or 2D (1 10 dB or 90 dB step attenuator[...]
-
Page 64
3-4 682XXB/683XXB MM INSTRUMENT CRITCAL SPECIFICA TION RECOMMENDED MANUF ACTURER/MODEL TEST NUMBER Spectrum Analyzer , with External Mixers and Diplexer Assy Frequency Resolution: 0.01 to 65 GHz Resolution Bandwidth: 10 Hz T ektronix, Model 2794, with External Mixers: WM780K (18 to 26.5 GHz) WM780A (26.5 to 40 GHz) WM780U (40 to 60 GHz) WM780E (60 [...]
-
Page 65
682XXB/683XXB MM 3-5 INSTRUMENT CRITCAL SPECIFICA TION RECOMMENDED MANUF ACTURER/MODEL TEST NUMBER Adapter WR15 to V (male) Adapts the MP716A4 Power Sensor to the 682XXB/683XXB RF OUTPUT connector (>40 GHz) ANRITSU, Model 35WR15V 3-1 1 Attenuator Frequency Range: DC to 40 GHz Max Input Power: >+17 dBm Attenuation: 10 dB ANRITSU, Model 41KC-10[...]
-
Page 66
3-5 682XXB/683XXB POWER LEVELS T able 3-2 is a listing of the Series 682XXB and 683XXB Synthesized Signal Generator models and their maximum leveled ouput power lev - els. Certain test procedures will refer you to this table for the maxi - mum leveled output power level setting of the instrument model being tested. 3-6 682XXB/683XXB MM PERFORMANCE [...]
-
Page 67
682XXB/683XXB MM 3-7 PERFORMANCE 682XXB/683XXB VERIFICATION POWER LEVELS 68XXXB Model Frequency (GHz) Max Leveled Output Power Max Leveled Output Power w/Step Attenuator 68X95B 0.5 – 2.2 GHz 2.2 – 20.0 GHz 20.0 – 40.0 GHz 40.0 – 50.0 GHz 50.0 – 65.0 GH +1 1.0 dBm +10.0 dBm +2.5 dBm 0.0 dBm –2.0 dBm Not Available 68X97B 0.01 – 2.0 GHz [...]
-
Page 68
3-6 INTERNAL TIME BASE AGING RA TE TEST (Optional) The following test can be used to verify that the 682XXB/683XXB 10 MHz time base is within its aging specification. The instrument de - rives its frequency accuracy from an internal 100 MHz crystal oscilla - tor standard. (W ith Option 16 installed, frequency accuracy is derived from an internal hi[...]
-
Page 69
T est Procedure The frequency error is measured at the start and finish of the test time period of 24 hours. The aging rate is the difference between the two error read - ings. 1. Set up the Frequency Reference as follows: a. Press the ESC key until the MAIN MENU is displayed. b. At the MAIN MENU display , press 1 to select CONFIGURATION . c. At th[...]
-
Page 70
4. Record the frequency error value, displayed on the Frequency Reference , on the T est Record. 5. W ait for 24 hours , then record the current fre - quency error value on the T est Record. 6. The aging rate is the difference between the two frequency error values. 7. Record the computed result on the T est Record. T o meet the specification, the [...]
-
Page 71
3-7 FREQUENCY SYNTHESIS TESTS The following tests can be used to verify correct operation of the fre - quency synthesis circuits. Frequency synthesis testing is divided into two parts—coarse loop/YIG loop tests and fine loop tests. T est Setup Connect the equipment, shown in Figure 3-2, as fol- lows: 1. Connect the 682XXB/683XXB rear panel 10 MHz[...]
-
Page 72
Coarse Loop/ YIG Loop T est Procedure The following procedure tests both the coarse loop and YIG loop by stepping the signal generator through its full frequency range in 1 GHz steps and measuring the RF output at each step. 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is [...]
-
Page 73
Fine Loop T est Procedure The following procedure tests the fine loop by step - ping the instrument through ten 1 kHz steps (ten 100 Hz steps for instruments with Option 1 1) and measuring the RF output at each step. 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is dis - pl[...]
-
Page 74
3-8 SPURIOUS SIGNALS TEST : RF OUTPUT SIGNALS £ 2 GHz ( £ 2.2 GHz for 68XX5B MODELS) The following test can be used to verify that the signal generator meets its spurious signals specifications for RF output signals from 0.01 to 2 GHz (0.5 to 2.2 GHz for 682X5B/683X5B Models). This test is applicable only to instruments which cover the frequency [...]
-
Page 75
2. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset the CW Menu is dis - played. b. Press Edit L1 to open the current power level parameter for editing. c. Set L1 to the lesser of +10 dBm or the maxi - mum leveled power level for the instrument being tested (refer to T able 3-2, page 3-6). d.[...]
-
Page 76
presence by entering their levels on the T est Re - cord. 9. Set F1 to 1.6 GHz. Measure the worst case non- harmonic signal for the 1.6 GHz carrier and rec - ord its presence by entering its level on the T est Record. 10. Change the Spectrum Analyzer setup as follows: a. Span: 10 MHz/div b. CF: 1.6 GHz c. RBW : 1 MHz 1 1. Adjust the Spectrum Analyz[...]
-
Page 77
0.5 - 2.2 GHz T est Procedure The following procedure lets you measure the 0.5 to 2.2 GHz RF output harmonic levels to verify that they meet specifications. 1. Set up the 682X5B/683X5B as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset the CW Menu is dis - played. b. Press Edit L1 to open the current power level parame[...]
-
Page 78
3-9 HARMONIC TEST : RF OUTPUT SIGNALS FROM 2 TO 20 GHz The following test can be used to verify that the 682XXB/683XXB meets its harmonic specifications for RF output signals from 2 to 20 GHz (2.2 to 20 GHz for 68XX5B Models). T est record entries are supplied for harmonics up to a frequency limit of 40 GHz. Additional harmonic checks may be made a[...]
-
Page 79
T est Procedure (2 to 10 GHz) The following procedure lets you measure the 2 to 10 GHz (2.2 to 10 GHz for 68XX5Bs) RF output har - monic levels to verify that they meet specifications. 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset the CW Menu is dis - played. b. Press Edit L1 to open th[...]
-
Page 80
T est Procedure (1 1 to 20 GHz) The following procedure lets you measure the 1 1 to 20 GHz RF output harmonic levels to verify that they meet specifications. NOTE Because an external mixer is required for these measurements, the RF output flat - ness of the signal generator is used to cor - rect for; (1) variations caused by switching from the fund[...]
-
Page 81
slightly to accomplish this; however , do not exceed –-20 dBm output power . 4. Remove Connection A and connect the 682XXB/ 683XXB RF OUTPUT to the waveguide mixer in - put of the Spectrum Analyzer as shown in Con - nection B. 5. On the 682XXB/683XXB, remove 30 dB of at - tenuation from the RF output. Do this by either increasing the output power[...]
-
Page 82
3-10 SINGLE SIDEBAND PHASE NOISE TEST The following test can be used to verify that the signal generator meets its single sideband phase noise specifications. For this test, a second 682XXB/683XXB is required. This additional instrument acts as a local oscillator (LO). The CW RF output of the 682XXB/683XXB under test (DUT) is mixed with the CW RF o[...]
-
Page 83
T est Procedure The following procedure lets you measure the RF output single sideband phase noise levels to verify that they meet specifications. NOTE The following technique is a measurement of phase noise and AM noise. T o avoid erro - neous results, on the 682XXB/683XXB DUT set L1 for maximum leveled output power and select External Detector le[...]
-
Page 84
NOTE If the 682XXB/683XXB LO output is less than 10 dBm, the Mixer ’ s local oscillator port will not be saturated and the resulting measurements may be in error . 3. Set up the Spectrum Analyzer as follows: a. Center Frequency: 1 MHz b. Frequency Span: 300 Hz c. RBW : 3 Hz d. Position the Marker to the peak of the signal. e. Select OFFSET , ENTE[...]
-
Page 85
9. On the Spectrum Analyzer: a. Deselect NOISE L VL. b. Set Frequency Span to 300 kHz. c. Adjust the Marker for a 100 kHz offset. d. Select NOISE L VL. 10. Measure the phase noise level 100 kHz offset from the carrier frequency . Record the level on the T est Record. 1 1. Repeat steps 1 through 10 for all frequencies listed on the T est Record. 682[...]
-
Page 86
3-1 1 POWER LEVEL ACCURACY AND FLA TNESS TESTS The following tests can be used to verify that the 682XXB/683XXB meets its power level specifications. Power level verification testing is divided into two parts—power level accuracy tests and power level flatness tests. T est Setup Connect the equipment, shown in Figure 3-6, as fol- lows: 1. Calibra[...]
-
Page 87
Power Level Accuracy T est Procedure Power level accuracy is tested by stepping the out - put power level down in 1 dB increments from its maximum rated power level and measuring the out - put power level at each step. 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is dis - [...]
-
Page 88
c. W ith the Step Sweep Menu displayed, press the main menu key FREQUENCY CONTROL The Sweep Frequency Control Menu is then displayed. d. Press Full to select a full range frequency sweep. e. Press Edit L1 to open the current power level parameter for editing. f. Set L1 to the power level indicated on the test record. g. Now , return to the Step Swe[...]
-
Page 89
3. Set up the 683XXB as follows for an analog sweep power level flatness test: a. Reset the instrument by pressing SYSTEM , then Reset . The CW Menu is displayed. b. Press Analog to place the 683XXB in the ana - log sweep frequency mode and display the Analog Sweep Menu. c. W ith the Analog Sweep Menu displayed, press the main menu key FREQUENCY CO[...]
-
Page 90
3-12 AMPLITUDE MODULA TION TEST This procedure verifies the operation of the 682XXB/683XXB ampli - tude modulation input sensitivity circuit. The RF OUTPUT of the 682XXB/683XXB is monitored on a Spectrum Analyzer display . The (modulated) IF Output of the Spectrum Ana - lyzer is monitored with a Modulation Analyzer . A 50% AM (default value) signal[...]
-
Page 91
AM Input Sensitivity Procedure The following procedure lets you measure the abso - lute peak AM values for a 50% AM signal and calcu - late the actual modulation value. 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is dis - played. b. Press Edit F1 to open the current frequ[...]
-
Page 92
8. Compute the actual AM input sensitivity with the following formula: % |( ) | |( – ) | |( ) | |( – ) | AM AM PK AM PK AM PK AM PK =´ ++ ++ - 100 200 é ë ê ù û ú 9. The calculated result should be between 45% and 55% AM. Record this result in the T est Record. 3-32 682XXB/683XXB MM PERFORMANCE AMPLITUDE VERIFICATION MODULATION TEST[...]
-
Page 93
3-13 FREQUENCY MODULA TION TESTS This procedure verifies the operation of the 682XXB/683XXB fre - quency modulation input sensitivity circuitry . The RF OUTPUT of the 682XXB/683XXB is monitored on a Spectrum Analyzer display . In Unlocked Wide FM mode, the Spectrum Analyzer is used as a frequency counter to measure the actual FM deviation and deter[...]
-
Page 94
Unlocked W ide FM Mode 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is dis - played. b. Press Edit F1 to open the current frequency parameter for editing. c. Set F1 to 5.0 GHz. 2. Set up the Spectrum Analyzer as follows: a. CF: 5.0 GHz b. Span/Div: 50 MHz (500 MHz across t[...]
-
Page 95
5. The difference between these two frequencies is the actual peak-to-peak frequency deviation. It should be between 190 MHz and 210 MHz. Record the difference on the T est Record. Unlocked Narrow FM Mode 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is dis - played. b. Pre[...]
-
Page 96
7. Compute the FM accuracy with the following for - mula: Accuracy in FM Deviation in kHz (% ) () = æ è ç ö ø ÷ ´ 240 100 8. The calculated result should be between 93.7% and 106.3%. Record this result on the T est Re - cord. Locked FM Mode 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon[...]
-
Page 97
6. Compute the FM accuracy with the following for - mula: Accuracy in FM Deviation in kHz (% ) () = æ è ç ö ø ÷ ´ 240 100 7. The calculated result should be between 93.7% and 106.3%. Record this result on the T est Re - cord. Locked Low-Noise FM Mode 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Re[...]
-
Page 98
6. Compute the FM accuracy with the following for - mula: Accuracy in FM Deviation in kHz (% ) () = æ è ç ö ø ÷ ´ 240 100 7. The calculated result should be between 93.7% and 106.3%. Record this result on the T est Re - cord. 3-38 682XXB/683XXB MM PERFORMANCE FREQUENCY VERIFICATION MODULATION TESTS[...]
-
Page 99
3-14 PULSE MODULA TION TESTS: RISE TIME, F ALL TIME, OVER- SHOOT , AND LEVEL Pulse modulation tests verify correct operation as well as rise time, fall time, overshoot, and level. The pulse leveling accuracy test compares the pulsed RF output level to verify the performance of the level detector(s), detector amplifiers, and ALC sample/ hold circuit[...]
-
Page 100
Rise/Fall T ime and Overshoot The following procedure lets you measure the rise time, fall time, and overshoot parameters of the pulse modulation waveform. 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is dis - played. b. Press Edit F1 to open the current frequency paramete[...]
-
Page 101
Pulse Leveling Accuracy The following procedure lets you measure the pulsed RF output level and CW output level and compare them to verify pulse leveling accuracy . 1. On the 682XXB/683XXB: a. Press On/Off (Internal Pulse Status menu) to turn off pulse modulation. b. Press CW/SWEEP SELECT to return to the CW Menu display . c. At the CW menu, press [...]
-
Page 102
3. On the 682XXB/683XXB: a. Press MODULA TION , then Pulse to go to the Internal Pulse Status Menu display . b. Press Edit Width and set W1 to the pulse width noted in the T est Record. c. Press On/Off to turn on pulse modulation. 4. On the Oscilloscope, observe that the nominal level of the displayed pulse peak has shifted ver - tically , slightly[...]
-
Page 103
3-15 PULSE MODULA TION TEST : VIDEO FEEDTHROUGH This pulse modulation test verifies that video feedthrough is within specifications. T est Setup Connect the equipment, shown in Figure 3-12, as follows: 1. Connect the 682XXB/683XXB rear panel PULSE SYNC OUT to the Oscilloscope T rigger Input. 2. On the Oscilloscope, select 50 W input impedance. 3. C[...]
-
Page 104
T est Procedure The following procedure lets you measure the video feedthrough that occurs during pulse modulation. 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is dis - played. b. Press Edit F1 to open the current frequency parameter for editing. c. Set F1 to 5.0 GHz. d. [...]
-
Page 105
3-16 PULSE MODULA TION TEST : RF ON/OFF RA TIO This pulse modulation test verifies that the ratio of RF on power to RF off power is within specifications. T est Setup Connect the equipment, shown in Figure 3-13, as follows: 1. Connect the 682XXB/683XXB rear panel 10 MHZ REF OUT to the Spectrum Analyzer External Ref- erence Input. 2. Connect the RF [...]
-
Page 106
e. Press More to go to the additional Internal Pulse Status Menu display . g. Press Internal/External to select the external source for the modulation signal. The External Pulse Status Menu is displayed. h. Press Front/Rear to select the rear panel PULSE TRIGGER IN connector . i. Press On/Off to turn pulse modulation on. 2. Set up the Spectrum Anal[...]
-
Page 107
7. Repeat steps 1 through 6 for any other frequen - cies noted on the T est Record. Record the results on the T est Record. 682XXB/683XXB MM 3-47 PERFORMANCE PULSE MODULATION TEST: VERIFICATION RF ON/OFF RATIO[...]
-
Page 108
3-17 PHASE MODULA TION TESTS This procedure verifies the operation of the phase modulation ( F M) in - put sensitivity circuits in 682XXB/683XXBs with Option 6. The carrier level of the 682XXB/683XXB RF output is monitored on a Spectrum Analyzer display . F M accuracy , in both Wide and Narrow F M modes, is determined by measuring the actual F M de[...]
-
Page 109
WIDE F M Mode 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is dis - played. b. Press Edit F1 to open the current frequency parameter for editing. c. Set F1 to 5.0 GHz. 2. Set up the Spectrum Analyzer as follows: a. CF: 5.0 GHz b. Span/Div: 100 kHz (1 MHz across the display[...]
-
Page 110
Narrow F M Mode 1. Set up the 682XXB/683XXB as follows: a. Reset the instrument by pressing SYSTEM , then Reset . Upon reset, the CW Menu is dis - played. b. Press Edit F1 to open the current frequency parameter for editing. c. Set F1 to 5.0 GHz. 2. Set up the Spectrum Analyzer as follows: a. CF: 5.0 GHz b. Span/Div: 100 kHz (1 MHz across the displ[...]
-
Page 111
T able of Contents 4-1 INTRODUCTION ................... 4-3 4-2 RECOMMENDED TEST EQUIPMENT ....... 4-3 4-3 TEST RECORDS ...................4 - 3 4-4 CALIBRA TION FOLLOWING SUBASSEMBL Y REPLACEMENT ...................4 - 4 4-5 CONNECTOR AND KEY LABEL NOT A TION . . . 4-4 4-6 INITIAL SETUP ....................4 - 7 Interconnection .................4 [...]
-
Page 112
ALC Slope DAC Adjustment .......... 4-28 4-1 1 ALC BANDWIDTH CALIBRA TION ........ 4-31 Equipment Setup ................ 4-31 Bandwidth Calibration ............. 4-31 4-12 AM CALIBRA TION ................. 4-33 Equipment Setup ................ 4-33 AM Calibration Procedure ........... 4-34 4-13 FM CALIBRA TION – FIRMW ARE VERSIONS 1.01 TO 2.10 (V[...]
-
Page 113
Chapter 4 Calibration 4-1 INTRODUCTION This chapter contains procedures for calibrating the Series 682XXB/ 683XXB Synthesized Signal Generators. These procedures are typi - cally performed because out-of-tolerance conditions have been noted during performance verification testing (see Chapter 3) or as a result of replacement of subassemblies or RF [...]
-
Page 114
4-4 CALIBRA TION FOLLOWING SUBASSEMBL Y REPLACEMENT T able 4-2 (page 4-6) lists the calibration that should be performed fol - lowing the replacement of 682XXB/683XXB subassemblies or RF com - ponents. 4-5 CONNECTOR AND KEY LABEL NOT A TION The calibration procedures include many references to equipment in - terconnections and control settings. For[...]
-
Page 115
682XXB/683XXB MM 4-5 RECOMMENDED CALIBRATION TEST EQUIPMENT INSTRUMENT CRITICAL SPECIFICA TION RECOMMENDED MANUF ACTURER/MODEL PROCEDURE NUMBER Scalar Network Analyzer , with RF Detector Frequency Range: 0.01 to 50 GHz ANRITSU Model 562, with RF Detector: 560-7K50 (0.01 to 40 GHz) 560-7V A50 (0.01 to 50 GHz) SC5198 (40 to 60 GHz) 4-8, 4-10 Adapter [...]
-
Page 116
4-6 682XXB/683XXB MM Subassembly/RF Component Replaced Perform the Following Calibration(s) in Paragraph(s): A1, A2 Front Panel Assy None A3 Reference Loop PCB 4-7 A4 Coarse Loop PCB 4-7 A5 Fine Loop PCB 4-7 A6 Pulse Generator PCB None A7 YIG Loop PCB None A8 Function Generator PCB 4-12 A9 PIN Control PCB 4-8, 4-9, 4-10, 4-1 1 A10 ALC PCB 4-8, 4-9,[...]
-
Page 117
4-6 INITIAL SETUP The 682XXB/683XXB is calibrated using an IBM compatible PC and external test equipment. The PC must have the W indows 3.1 or W in - dows 95 operating system installed and be equipped with a mouse. Initial setup consists of interfacing the PC to the signal generator . Interconnec - tion Using the ANRITSU P/N T1678 serial interface [...]
-
Page 118
PC Setup — W indows 3.1 Configure the PC with Windows 3.1 operating sys - tem to interface with the 682XXB/683XXB as fol - lows: 1. Power up the 682XXB/683XXB. 2. Power up the PC and place it in W indows. 3. Double click on the T erminal Icon to bring up the T erminal (Untitled) window . The initial installa - tion of W indows places the T ermina[...]
-
Page 119
5. Click on Communications. 6. At the Communications Dialog box, select the fol- lowing options: B aud Rate 9600 (See Note) D ata Bits 8 S top Bits 1 P arity None F low Control Xon/Xoff C onnector Select connection made during interconnection 682XXB/683XXB MM 4-9 CALIBRATION INITIAL SETUP NOTE When calibrating instruments with operating firmware V [...]
-
Page 120
7. After making the selections, click on the OK but - ton. 8. Press <ENTER> on the keyboard. 9. V erify that a $ prompt appears on the PC display . 10. This completes the initial setup for calibration. PC Setup — W indows 95 Configure the PC with W indows 95 operating sys - tem to interface with the 682XXB/683XXB as fol - lows: 1. Power up [...]
-
Page 121
7. In the New Connection Name box, type a name for the connection, then click on the OK button. The window below is now displayed. 8. In the Connect using box, type Direct to Com “_” . Enter the number of the communica - tions port being used, for example: Com1. 9. Click on OK . The Communications Port Proper - ties window is displayed (next pa[...]
-
Page 122
10. In the Properties window , make the following se- lections: B its per second 19200 (See Note) D ata bits 8 P arity None S top bits 1 F low control Xon / Xoff 1 1. After making the selections, click on the OK but - ton. 12. Press <ENTER> on the keyboard. 13. V erify that the $ prompt appears on the PC dis - play . 14. This completes the in[...]
-
Page 123
4-7 PRELIMINARY CALIBRA TION This procedure provides the steps necessary to initially calibrate the coarse loop, fine loop, frequency instruction, and internal DVM cir - cuitry and the 100 MHz reference oscillator of the 682XXB/683XXB. Equipment Setup Connect the equipment, shown in Figure 4-2, as fol- lows: 1. Interface the PC to the 682XXB/683XXB[...]
-
Page 124
Calibration Steps Each of the steps in this procedure provides initial calibration of a specific 682XXB/683XXB circuit or component. T o ensure accurate instrument calibra - tion, each step of this procedure must be performed in sequence. 1. Calibrate the internal DVM circuitry as follows: a. At the $ prompt, type: calterm 119 and press <ENTER&g[...]
-
Page 125
6. Calibrate the YIG Frequency Linearizer DACs as follows: a. At the $ prompt, type: calterm 127 and press <ENTER>. b. Follow the instructions on the screen. Enter the value of the frequency counter reading as XXXX MHz. c Record step completion on the T est Record. 7. Calibrate the 100 MHz Reference Oscillator as follows: a. If Option 16 (Hig[...]
-
Page 126
10. Calibrate the Center Frequency DAC as follows: a. At the $ prompt, type: calterm 114 and press <ENTER>. (The $ prompt will appear on the screen when the calibration is complete.) b. Record step completion on the T est Record. 1 1. Store the calibration data as follows: a. At the $ prompt, type: calterm 787 and press <ENTER>. (The $ [...]
-
Page 127
4-8 SWITCHED FIL TER SHAPER CALIBRA TION This procedure provides the steps necessary to adjust the Switched Filter Shaper Amplifier gain to produce a more constant level ampli - fier gain with power level changes. Equipment Setup Connect the equipment, shown in Figure 4-3, as fol- lows: 1. Interface the PC to the 682XXB/683XXB by per- forming the i[...]
-
Page 128
Log Amplifier Zero Calibra - tion Before the Switched Filter Shaper Amplifier can be adjusted, zero calibration of the ALC Log amplifier must be performed to eliminate any DC offsets. 1. Perform ALC Log amplifier zero calibration as follows: a. At the $ prompt on the PC display , type: calterm 115 and press <ENTER>. The $ prompt will appear o[...]
-
Page 129
2. Adjust the Switched Filter Limiter DAC for each of the frequency bands as follows: a. At the $ prompt on the PC display , type: calterm 145 and press <ENTER>. b. On the 562 Network Analyzer , set the Resolu - tion to 0.2 dB and adjust the offset to center the top of the triangle waveform on the display . c. Observe the displayed waveform t[...]
-
Page 130
c. Press CHANNEL 2 DISPLA Y : OFF . d. Press CHANNEL 1 DISPLA Y : ON. e. Press CHANNEL 1 MENU key . f. From the Channel 1 Menu display , select POWER. g. Press OFFSET/RESOLUTION. b. Set Resolution to 5 dB/Div . c. Adjust Offset to center the display . 2. Adjust the Switched Filter Shaper DAC for each of the frequency bands as follows: a. At the $ p[...]
-
Page 131
Shaper DAC Adjustment For Models 682XXB with Firmware V ersion 2.39 and above; Models 683XXB with Firmware V ersion 2.46 and above; Models 682X5B with Firmware V ersion 1.28 and above; and Models 683X5B with Firmware V ersion 1.32 and above. The following step in the procedure adjusts the Switch Filter Shaper DAC which controls the gain of the Swit[...]
-
Page 132
4-9 RF LEVEL CALIBRA TION RF level calibration requires the use of an automated test system. A computer-controlled power meter measures the 682XXB/683XXB power output at many frequencies throughout the frequency range of the instrument. Correction factors are then calculated and stored in non-volatile memory (EEPROM) located on the A17 CPU PCB. Thi[...]
-
Page 133
4-10 ALC SLOPE CALIBRA TION Models 683XXB with Firmware V ersion 1.01 to 2.00 This procedure provides the steps necessary to perform ALC Slope calibration. The ALC Slope DAC is calibrated to adjust for an increas - ing or decreasing output power-vs-output frequency in the analog sweep mode. The ALC Slope DAC has two calibrations—one for fre - que[...]
-
Page 134
NOTE Before beginning this calibration proce - dure, always let the 683XXB warm up for a minimum of one hour . ALC Slope DAC Adjustment The following procedure lets you adjust the ALC Slope DAC to compensate for decreasing output power-vs-frequency for frequencies £ 2 GHz and for frequencies >2 GHz. 1. Set up the 562 Network Analyzer as follows[...]
-
Page 135
3. Make the following selections on the 562 Network Analyzer to normalize the step sweep. a. Press CALIBRA TION and follow the menu on the display . b. Press AUTOSCALE. c. Press OFFSET/RESOLUTION and set the Resolution to 0.2 dB. 4. On the 683XXB, press Analog to select the ana - log sweep mode. 5. Adjust the ALC Slope DAC for frequencies £ 2 GHz [...]
-
Page 136
f. Press Sweep Ramp . At the resulting Step Sweep Ramp Menu, press Num of Steps and set the number of steps to 200. g. Press Step to return to the Step Sweep Menu display . 7. Make the following selections on the 562 Network Analyzer to normalize the step sweep. a. Press CALIBRA TION and follow the menu on the display . b. Press AUTOSCALE. c. Press[...]
-
Page 137
Models 683XXB with Firmware V ersion 2.00 and above (Models 683X5B with Firmware V ersion 1.00 and above) This procedure provides the steps necessary to perform ALC Slope calibration. The ALC Slope is calibrated to adjust for decreasing out - put power-vs-output frequency in full band analog sweep. Equipment Setup Connect the equipment, shown in Fi[...]
-
Page 138
NOTE Before beginning this calibration proce - dure, always let the 682XXB/683XXB warm up for a minimum of one hour . ALC Slope DAC Adjustment The following procedure lets you adjust the ALC Slope over individual frequency ranges to compen - sate for decreasing output power-vs-frequency in analog sweep. The procedure begins by letting you adjust th[...]
-
Page 139
d. Press CW/SWEEP SELECT to return to the Step Sweep Menu display . e. Press Sweep Ramp . At the resulting Step Sweep Ramp Menu, press Num of Steps and set the number of steps to 400. 3. Make the following selections on the 562 Network Analyzer to normalize the step sweep. a. Press CALIBRA TION and follow the menu on the display . b. Press AUTOSCAL[...]
-
Page 140
b. Adjust the ALC Slope so that the power at the start and stop frequencies (of the analog sweep for band 0) match as closely as possible the normalized straight line in step sweep mode. When completed, press n for the next band. c. Using the Slope and Offset adjustment keys, continue until the ALC Slope for all bands has been adjusted. d. T ype: X[...]
-
Page 141
4-1 1 ALC BANDWIDTH CALIBRA TION This procedure provides the steps necessary to perform ALC Band - width calibration. The ALC Bandwidth is adjusted to compensate for gain variations of the modulator . The adjustment is performed for each frequency band. This provides a more consistent bandwith throughout the frequency range of the instrument. Equip[...]
-
Page 142
The $ prompt will appear on the screen when the ALC Bandwidth calibration is complete. (This can take up to 15 minutes depending on the frequency range of the 682XXB/683XXB.) b. Record step completion on the T est Record. 2. Store the calibration data as follows: a. At the $ prompt, type: calterm 787 and press <ENTER>. (The $ prompt will appe[...]
-
Page 143
4-12 AM CALIBRA TION This procedure provides the steps necessary to perform AM calibra - tion. This consists of calibrating the AM Calibration DAC, the AM Me - ter circuit, and the AM Function Generator . The AM Calibration DAC is calibrated for input sensitivities of 100%/V (linear mode) and 25 dB/V (logarithmic mode) for frequencies £ 2 GHz and [...]
-
Page 144
4. Using the K (male) to 2.4 mm (female) adapter , connect the Power Sensor to the RF OUTPUT of the 682XXB/683XXB. NOTE Before beginning this calibration proce - dure, always let the 682XXB/683XXB warm up for a minimum of one hour . AM Calibration Procedure The following procedure let you (1) adjust the AM Calibration DAC to provide the correct amo[...]
-
Page 145
e. When the DAC has been adjusted, press Q on the keyboard to exit the program. (If the in - strument has a Down Converter installed, you will be returned to the start of the program to perform this calibration for frequencies of >2 GHz.) When the DAC has been completely adjusted, the program will exit to the $ prompt. e. Record step completion [...]
-
Page 146
5. Perform AM Function Generator calibration as follows: a. At the $ prompt, type: calterm 146 and press <ENTER>. (The $ prompt will appear on the screen when the calibration is complete.) b. Record step completion on the T est Record. 6. Store the calibration data as follows: a. At the $ prompt, type: calterm 787 and press <ENTER>. (Th[...]
-
Page 147
4-13 FM CALIBRA TION Models 682XXB/683XXB with Firmware V ersions 1.01 to 2.10 Models 682X5B/683X5B with Firmwave V ersion 1.00 This procedure provides the steps necessary to perform FM calibra - tion. This consists of calibrating the FM Meter circuit, the Offset Bal - ance DAC, and the FM Gain Control DAC. The FM Gain Control DAC is calibrated for[...]
-
Page 148
4. Connect the 682XXB/683XXB RF OUTPUT to the Spectrum Analyzer RF Input. NOTE Before beginning this calibration proce - dure, always let the 682XXB/683XXB warm up for a minimum of one hour . FM Calibration Procedure The following steps in the procedure lets you (1) calibrate the FM Meter circuit, (2) calibrate the FM Offset Balance DAC, (3) adjust[...]
-
Page 149
Perform the calibration as follows: a. At the $ prompt, type: calterm 124 and press <ENTER>. b. Set up the Function Generator for a 0.4 Hz square wave with an output level of 2 volts peak to peak. c. On the Spectrum Analyzer , set the Span/Div to 50 MHz per division. d. On the computer keyboard, use the ‘, 1, 2, and 3 keys to increment and [...]
-
Page 150
m. Now , adjust the center frequency control to po - sition the high carrier at the center of the dis - play . Note the frequency reading. n. The difference between these two frequencies is the actual peak-to-peak frequency deviation. It should be 20 MHz ± 0.8 MHz. If not, fine ad - just the value of the DAC’ s setting to obtain this deviation. [...]
-
Page 151
f. When finished setting the DAC, press Q on the keyboard to go to the next calibration step. When the DAC has been completely adjusted, the program will exit to the $ prompt. g. Record step completion on the T est Record. 5. Internal FM W ide mode sensitivity calibration is accomplished by adjusting the FM Gain Control DAC to obtain 200 MHz and 20[...]
-
Page 152
quency control to position the high (or low) car - rier at the center of the display . Note the frequency reading. j. On the keyboard, enter 1 to toggle the polarity . k. Now , adjust the center frequency control to po - sition the low (or high) carrier at the center of the display . Note the frequency reading. l. The difference between these two f[...]
-
Page 153
w. When finished setting the DAC, press Q on the keyboard to return to the menu. Then, enter 3 to go to the next calibration step (adjusting the DAC to obtain 200 MHz deviation at 15 GHz). When the DAC has been completely adjusted, the program will exit to the $ prompt. x. Record step completion on the T est Record. 6. Internal FM Narrow mode sensi[...]
-
Page 154
Models 682XXB with Firmware V ersion 2.18 and above Models 683XXB with Firmwave V ersion 2.20 and above Models 682X5B/683X5B with Firmware V ersion 1.07 and above This procedure provides the steps necessary to perform FM calibra - tion. This consists of calibrating the FM Meter circuit and the FM V ariable Gain Control DAC. The FM V ariable Gain Co[...]
-
Page 155
4. Connect the 682XXB/683XXB RF OUTPUT to the Spectrum Analyzer RF Input. NOTE Before beginning this calibration proce - dure, always let the 682XXB/683XXB warm up for a minimum of one hour . FM Calibration Procedure The following steps in the procedure lets you cali - brate the (1) FM Meter circuit; (2) FM V ariable Gain Linearity; (3) Locked, Loc[...]
-
Page 156
3. External Unlocked W ide FM Mode Sensitivity calibration is accomplished by adjusting the FM V ariable Gain Control DAC to obtain a 200 MHz FM deviation at frequencies of 5 GHz and 15 GHz. The modulating signal input is from the external Function Generator . Perform the calibration as follows: a. At the $ prompt, type: calterm 124 and press <E[...]
-
Page 157
4. Internal Unlocked W ide FM Mode Sensitivity calibration is accomplished by adjusting the FM V ariable Gain Control DAC to obtain a 200 MHz FM deviation at frequencies of 5 GHz and 15 GHz. The modulating signal input is from the internal Function Generator . Perform the calibration as follows: a. At the $ prompt, type: calterm 143 and press <E[...]
-
Page 158
k. Now adjust the center frequency control to po - sition the low (or high) carrier at the center of the display . Note the frequency reading. l. The difference between these two frequencies should be 200 MHz ± 0.5 MHz. If not, enter 2 and fine adjust the DAC to obtain this devia - tion. m. When finished setting the DAC, press Q on the keyboard to[...]
-
Page 159
When the DAC has been completely adjusted, the program will exit to the $ prompt. g. Record step completion on the T est Record. 6. Internal Locked, Locked Low-Noise, and Un - locked Narrow FM Mode Sensitivity calibration is accomplished by adjusting the FM V ariable Gain Control DAC to reduce the carrier level as low as possible at frequencies of [...]
-
Page 160
c. Set up the Function Generator for a 99.8 kHz sine wave with an output level of 0.707 volts RMS (2 volts peak to peak). Use a frequency counter to verify the output frequency of your function generator is set to ± 1%. d. On the Spectrum Analyzer , set the Span/Div to 50 kHz per division. e. On the computer keyboard, use the ‘, 1, 2. and 3 keys[...]
-
Page 161
4-14 PHASE MODULA TION ( F M) CALIBRA TION This procedure provides the steps necessary to perform phase modula - tion ( F M) calibration for 682XXB/683XXBs with Option 6. This con - sists of calibrating the FM V ariable Gain Control DAC and the F M Flatness DAC for input sensitivities in Narrow and W ide F M modes. Equipment Setup Connect the equip[...]
-
Page 162
4. Connect the 682XXB/683XXB RF OUTPUT to the Spectrum Analyzer RF Input. NOTE Before beginning this calibration proce - dure, always let the 682XXB/683XXB warm up for a minimum of one hour . F M Calibration Procedure The following steps in the procedure lets you cali - brate the FM V ariable Gain Control DAC and the F M Flatness DAC in both W ide [...]
-
Page 163
When the DAC has been completely adjusted, the program will exit to the $ prompt. g. Record step completion on the T est Record. 2. Internal W ide F M Mode Sensitivity calibration is accomplished by adjusting the FM V ariable Gain Control DAC to reduce the carrier level as low as possible at frequencies of 5 GHz and 20 GHz. The modulating signal in[...]
-
Page 164
c. On the Spectrum Analyzer , set the Span/Div to 50 kHz per division. d. On the computer keyboard, use the ‘, 1, 2, and 3 keys to increment and the 7, 8, 9, and 0 keys to decrement the value of the DAC’ s setting. Start calibration by pressing an increment key . e. While observing the first Bessel null (Figure 4-16) on the Spectrum Analyzer di[...]
-
Page 165
When the DAC has been completely adjusted, the program will exit to the $ prompt. g. Record step completion on the T est Record. 5. Internal Narrow F M Mode Sensitivity calibration is accomplished by adjusting the FM V ariable Gain Control DAC to reduce the carrier level as low as possible at frequencies of 5 GHz and 20 GHz. The modulating signal i[...]
-
Page 166
c. On the Spectrum Analyzer , set the Span/Div ot 50 kHz per division. d. On the computer keyboard, use the ‘, 1, 2, and 3 keys to increment and the 7, 8, 9, and 0 keys to decrement the value of the DAC’ s setting. Start the calibration by pressing an increment key . e. While observing the first Bessel null (Figure 4-16) on the Spectrum Analyze[...]
-
Page 167
T able of Contents 5-1 INTRODUCTION ................... 5-3 5-2 RECOMMENDED TEST EQUIPMENT ....... 5-3 5-3 ERROR AND W ARNING/ST A TUS MESSAGES. . . 5-3 Self-T est Error Messages .............5 - 3 Normal Operation Error and W arning/Status Messages ....................5 - 7 5-4 MALFUNCTIONS NOT DISPLA YING AN ERROR MESSAGE ..................... 5-[...]
-
Page 168
The majority of the troubleshooting procedures presented in this chapter require the removal of the instrument covers to gain access to test points on printed circuit boards and other subassemblies. W ARNING Hazardous voltages are present inside the 682XXB/683XXB whenever ac line power is connected. T urn off the instrument and remove the line cord[...]
-
Page 169
Chapter 5 T r oubleshooting 5-1 INTRODUCTION This chapter provides information for troubleshooting signal generator malfunctions. The troubleshooting procedures presented in this chap - ter support fault isolation to a replaceable subassembly or RF compo - nent. (Remove and replace procedures for the subassemblies and RF components are found in Cha[...]
-
Page 170
5-4 682XXB/683XXB MM Error Message T roubleshooting T able Page Number Error 100 DVM Ground Offset Failed 5-5 5-18 Error 101 DVM Positive 10V Reference 5-5 5-18 Error 102 DVM Negative 10V Reference 5-5 5-18 Error 105 Power Supply V oltage(s) out of Regulation 5-6 5-19 Error 106 Power Supply not Locked 5-6 5-28 Error 107 Sweep T ime Check Failed 5-1[...]
-
Page 171
682XXB/683XXB MM 5-5 Error Message T roubleshooting T able Page Number Error 120 Delta-F Circuits Failed 5-16 5-36 Error 121 Unleveled Indicator Failed 5-17 5-37 Error 122 Level Reference Failed 5-17 5-37 Error 123 Detector Log Amp Failed 5-17 5-37 Error 124 Full Band Unlocked and Unleveled 5-18 5-39 Error 125 8.4 – 20 GHz Unlocked and Unleveled [...]
-
Page 172
5-6 682XXB/683XXB MM SELF-TEST TROUBLESHOOTING ERROR MESSAGES Error Message T roubleshooting T able Page Number Error 144 RF was Off when Selftest started. Some tests were not performed. 5-24 5-51 Error 145 AM meter or associated circuitry failed 5-25 5-51 Error 147 Internal FM circuitry failed 5-26 5-52 Error 148 Pulse 40 MHz reference circuitry f[...]
-
Page 173
Normal Operation Error and W arning/ Status Messages When an abnormal condition is detected during op - eration, the 682XXB/683XXB displays an error mes - sage to indicate that the output is abnormal or that a signal input or data entry is invalid. It also dis - plays warning messages to alert the operator to conditions that could cause an inaccura[...]
-
Page 174
5-8 682XXB/683XXB MM Error Message Description ERR Continued: (2) The external FM modulating signal exceeds the input voltage range. In addition, the message “ Reduce FM Input Level ” appears at the bottom of the FM status display . (3) A pulse parameter setting is invalid for the current pulse modulation state, as follows: Single Pulse Mode: F[...]
-
Page 175
682XXB/683XXB MM 5-9 ERROR AND WARNING/ TROUBLESHOOTING STATUS MESSAGES W arning/Status Message Description OVN COLD This warning message indicates that the 100 MHz Crystal oven (or the 10 MHz Crystal oven if Option 16 is installed) has not reached operating temperature. Normally displayed during a cold start of the signal generator . If the messag[...]
-
Page 176
5-4 MALFUNCTIONS NOT DISPLA YING AN ERROR MESSAGE The 682XXB/683XXB must be operating to run self-test. Therefore, malfunctions that cause the instrument to be non-operational do not produce error messages. These problems generally are a failure of the 682XXB/683XXB to power up properly . T able 5-4, beginning on page 5-12, provides troubleshooting[...]
-
Page 177
682XXB/683XXB MM 5-11 J1 J2 J3 J4 J5 J6 J7 J1 J2 J3 J4 J5 J6 J7 J 1 J2 J3 J4 J5 J6 J7 J1 J2 J3 J4 J5 J6 J7 T est P oints Rear P anel A15 Regulator PCB A3 A4 A5 A6 A7 A9 A8 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A3 Refere nce Loop PCB A4 Coarse Loop PCB A5 Fine Loop PCB A6 Pulse Generator PCB A8 Function Generator PCB A7 YIG Loop PCB A9 PIN Control[...]
-
Page 178
5-12 682XXB/683XXB MM TROUBLESHOOTING TROUBLESHOOTING TABLES Signal Generator W ill Not T urn On ( OPERA TE light is OFF ) Normal Operation: When the 682XXB/683XXB is connected to the power source, the OPERA TE light should illuminate and the instru - ment should power up. Step 1. Disconnect the 682XXB/683XXB from the power source, then check the l[...]
-
Page 179
682XXB/683XXB MM 5-13 TROUBLESHOOTING TROUBLESHOOTING TABLES If the voltage is correct, the Front Panel assembly or the cable between Motherboard connector A20J22 and the Front Panel assembly may be defective. If the voltage is incorrect, the +24V standby power supply may be loaded down by (1) a shorted oven heater for the 100 MHz reference oscilla[...]
-
Page 180
5-14 682XXB/683XXB MM TROUBLESHOOTING TROUBLESHOOTING TABLES No Pulse Modulation of the RF Output Description: The signal generator does not display any error messages during self-test; however , there is no pulse modulation of the RF out - put. Step 1. Set up the 682XXB/683XXB as follows: a. Press SYSTEM , then Reset . b. Press MODULA TION , then [...]
-
Page 181
682XXB/683XXB MM 5-15 TROUBLESHOOTING TROUBLESHOOTING TABLES If the signals are present and correct, go to step 8. If the signals are not present or are incorrect, replace the A6 PCB. Step 8. Disconnect the cable, W123, from J7 of the Pulsed Switched Filter assembly . Step 9. Using the oscilloscope, verify the presence of a pulse train with an outp[...]
-
Page 182
5-16 682XXB/683XXB MM Output Power Related Problems (>40 GHz) 682XXB/683XXB Models with SQM Description: The signal generator does not display any error message during self-test; however , there is no or low RF output above 40 GHz. Step 1. Set up the 682XXB/683XXB as follows: a. 682XXB Setup: CW/SWEEP SELECT : Step F1: 40.0 GHz F2: 50.0, 60.0, o[...]
-
Page 183
682XXB/683XXB MM 5-17 TROUBLESHOOTING TROUBLESHOOTING TABLES Step 4. Connect a 562 Scalar Network Analyzer to the 682XXB/ 683XXB as follows: a. Connect the 682XXB/683XXB AUX I/O to the 562 AUX I/O . b. Connect the 562 DEDICA TED GPIB to the 682XXB/ w683XXB IEEE-488 GPIB . c. Connect the RF Detector to the 562 Channel A Input. Step 5. Set up the 562[...]
-
Page 184
5-18 682XXB/683XXB MM Internal DVM T ests Error 100 DVM Ground Offset Failed, or Error 101 DVM Positive 10V Reference, or Error 102 DVM Negative 10V Reference Description: The DVM circuitry , located on the A16 CPU Interface PCB, is calibrated using the ± 10 volts from the reference supplies on the A12 Analog Instruction PCB. The error messages in[...]
-
Page 185
682XXB/683XXB MM 5-19 TROUBLESHOOTING TROUBLESHOOTING TABLES Power Supply T ests W ARNING V oltages hazardous to life are present throughout the power supply circuits, even when the front panel LINE switch is in the ST ANDBY postion. When performing maintenance, use utmost care to avoid electrical shock. Error 105 Power Supply V oltage(s) out of Re[...]
-
Page 186
5-20 682XXB/683XXB MM TROUBLESHOOTING TROUBLESHOOTING TABLES Step 2. Perform the following procedure to isolate malfunctions when the voltages from several regulated supplies are incorrect. a. Place the LINE switch to ST ANDBY . b. Replace the A15 PCB assembly . c. Place the LINE switch to OPERA TE and measure the regulated voltages per T able 5-7.[...]
-
Page 187
682XXB/683XXB MM 5-21 ± 15VG Supply Problems This supply provides ± 15 volts to the YIG Driver; SDM, SQM Driver; CPU; and CPU I/O circuits andw the Switched Filter and Down Con - verter assemblies. Step 4. Perform the following procedure to isolate malfunctions to the ± 15VG supply and outlying load circuits. a. Place the LINE switch to ST ANDBY[...]
-
Page 188
5-22 682XXB/683XXB MM ± 15V A Supply Problems This supply provides ± 15 volts to the Function Generator , PIN Control, ALC, FM, and Analog Instruction circuits. Step 5. Perform the following procedure to isolate malfunctions to the ± 15V A supply and outlying load circuits. a. Place the LINE switch to ST ANDBY . b. Replace the A15 PCB assembly .[...]
-
Page 189
682XXB/683XXB MM 5-23 ± 15VLP Supply Problems This supply provides ± 15 volts to the Pulse Generator and the Refer - ence, Coarse, Fine, and YIG Loop circuits. Step 6. Perform the following procedure to isolate malfunctions to the ± 15VLP supply and outlying load circuits. a. Place the LINE switch to ST ANDBY . b. Replace the A15 PCB assembly . [...]
-
Page 190
5-24 682XXB/683XXB MM ± 15VFM Supply Problems This supply provides ± 15 volts to the FM circuits. Step 7. Perform the following procedure to isolate malfunctions to the ± 15VFM supply and its outlying load circuit. a. Place the LINE switch to ST ANDBY . b. Replace the A15 PCB assembly . c. Place the LINE switch to OPERA TE and measure the ± 15V[...]
-
Page 191
682XXB/683XXB MM 5-25 –18VT Supply Problems This supply provides –18 volts to the front panel LCD contrast circuit and to drive the YIG-tuned oscillator main tuning coil during CW and slow analog sweeps. Step 8. Perform the following procedure to isolate malfunctions to the –18VT supply and its outlying load circuit. a. Place the LINE switch [...]
-
Page 192
5-26 682XXB/683XXB MM –43VT Supply Problems This supply provides –43 volts to drive the YIG-tuned oscillator main tuning coil during bandswitching, fast analog sweeps, and digital sweeps. Step 9. Perform the following procedure to isolate malfunctions to the –43VT supply and its outlying load circuit. a. Place the LINE switch to ST ANDBY . b.[...]
-
Page 193
682XXB/683XXB MM 5-27 +24VH Supply Problems This supply provides +24 volts for the YIG-tuned oscillator heater , the V/GHz circuit on the A12 PCB, and the coarse, fine, and YIG loop circuits. When the 682XXB/683XXB is switched to OPERA TE , it also takes over the function of the 24VS supply and supplies +24 volts to the 100 MHz reference oscillator[...]
-
Page 194
5-28 682XXB/683XXB MM Power Supply Not Phase-Locked Error 106 Power Supply not Locked Description: The switching power supply is not phase locked to the 400 kHz reference signal from the A6 Pulse Generator PCB. Error 106 may be displayed alone or it may be accompanied by error 148 (Pulse 40 MHz reference circuitry failed). Power Supply not Locked a[...]
-
Page 195
682XXB/683XXB MM 5-29 A3 Reference Loop Error 108 Crystal Oven Cold Description: The oven of the 100 MHz crystal oscillator or the Option 16 high-stability 10 MHz crystal oscillator has not reached operating temperature. Step 1. Allow a 30 minute warm up, then run self-test again. If error 108 is not displayed, the problem is cleared. If error 108 [...]
-
Page 196
5-30 682XXB/683XXB MM Error 1 10 The 100MHz Reference is not Locked to the High Stability 10MHz Crystal Oscillator Description: The reference loop is not phase-locked to the Option 16 high stability 10 MHz crystal oscillator . Step 1. Disconnect the cable from A3J6. Step 2. Using an oscilloscope, verify the presence of a 10 MHz signal at the end of[...]
-
Page 197
682XXB/683XXB MM 5-31 Step 6. Using the spectrum analyzer , verify the presence of the +3 dBm ± 5 dB, 10 MHz signal at the end of the cable. If present, replace the A4 PCB. If not present, go to step 7. Step 7. Disconnect cable W105 at A3J4. Step 8. Using the spectrum analyzer , verify the presence of the +3 dBm ± 5 dB, 10 MHz signal at A3J4. If [...]
-
Page 198
5-32 682XXB/683XXB MM A4 Coarse Loop Error 1 12 Coarse Loop Osc Failed Description: The coarse loop oscillator is not phase-locked. Step 1. Disconnect cable W103 at A4J1 and cable W105 at A4J6. Step 2. Using a spectrum analyzer , verify the presence of a +5 dBm ± 6 dB, 500 MHz signal at the end of cable W103 and a +3 dBm ± 5 dB, 10 MHz signal at [...]
-
Page 199
682XXB/683XXB MM 5-33 A7 YIG Loop Error 1 13 YIG Loop Osc Failed Error 1 15 Not Locked Indicator Failed Description: Error 1 13 indicates that the YIG loop is not phase- locked. Error 1 15 indicates a failure of the not phased-lock indicator circuit. Step 1. V erify the signal output from the A4 Coarse Loop PCB by performing steps 5 thru 7 in T abl[...]
-
Page 200
5-34 682XXB/683XXB MM Step 8. Run self-test. If error 1 13 or 1 15 is not displayed, the problem is cleared. If either error 1 13 or 1 15 is displayed, contact your local ANRITSU service center for assistance. T able 5-13. Error Messages 1 13 and 1 15 (2 of 2) TROUBLESHOOTING TROUBLESHOOTING TABLES Down Converter Error 1 14 Down Converter LO not Lo[...]
-
Page 201
682XXB/683XXB MM 5-35 A1 1 FM PCB Error 1 16 FM Loop Gain Check Failed Description: The FM loop has failed or the loop gain is out of toler - ance. Step 1. Perform a preliminary calibration. (Refer to chapter 4 for the calibration procedure.) Step 2. Run self-test. If error 1 16 is not displayed, the problem is cleared. If error 1 16 is still displ[...]
-
Page 202
5-36 682XXB/683XXB MM TROUBLESHOOTING TROUBLESHOOTING TABLES A12 Analog Instruction Error 107 Sweep T ime Check Failed Error 1 17 Linearizer Check Failed Error 1 18 Switchpoint DAC Failed Error 1 19 Center Frequency Circuits Failed Error 120 Delta-F Circuits Failed Description: Each of these error messages indicates a problem in the circuitry on th[...]
-
Page 203
682XXB/683XXB MM 5-37 A10 ALC Error 121 Unleveled Indicator Failed Error 122 Level Reference Failed Error 123 Detector Log Amp Failed Error 127 Detector Input Circuit Failed Description: Error 121 indicates a failure of the circuit that alerts the CPU whenever the RF output power becomes unleveled. Each of the other error messages indicates a probl[...]
-
Page 204
5-38 682XXB/683XXB MM If present, replace the A10 PCB. If not present, replace the cable W122. Error 143 Slope DAC Failed Description: Error 143 indicates a problem with the level slope DAC circuitry on the A10 PCB. NOTE When troubleshooting this error in a 682XXB model, begin at step 3 of the procedure. Step 1. Recalibrate the ALC slope. (Refer to[...]
-
Page 205
682XXB/683XXB MM 5-39 YIG-tuned Oscillator Error 124 Full Band Unlocked and Unleveled Error 125 8.4-20 GHz Unlocked and Unleveled Error 126 2-8.4 GHz Unlocked and Unleveled Description: These error messages indicate either a failure of one or both of the oscillators in the 2-20 GHz YIG-tuned oscillator assembly . Step 1. Connect a 562 Scalar Networ[...]
-
Page 206
5-40 682XXB/683XXB MM If the RF signal is correct in both frequency and ampli - tude throughout the full sweep, go to step 8. If there is no RF signal for all or part of the sweep or if the amplitude of the RF signal is low , go to step 5. Step 5. Connect the X input of an oscilloscope to the 682XXB/ 683XXB rear panel HORIZ OUT connector . Step 6. [...]
-
Page 207
682XXB/683XXB MM 5-41 Output Power Level Related Problems (0.01 to 20 GHz) Error 128 .01-2 GHz Unleveled Description: Error 128 indicates a failure of of the down converter leveling circuitry . The 682XXB/683XXB may or may not produce an RF output in the 0.01 to 2 GHz frequency range. Thus, there are two trou - bleshooting paths for this problem—[...]
-
Page 208
5-42 682XXB/683XXB MM Unleveled with no/low output power: Step 1. Set up the 682XXB/683XXB as follows: a. 682XXB Setup: CW/SWEEP SELECT : Step F1: 0.010 GHz F2: 2.000 GHz Number of Steps: 400 L1: +1.00 dBm 683XXB Setup: CW/SWEEP SELECT : Analog F1: 0.010 GHz F2: 2.000 GHz Sweep Time: 0.100 Sec L1: +1.00 dBm b. LEVEL/ALC SELECT : ALC Mode Leveling M[...]
-
Page 209
682XXB/683XXB MM 5-43 Step 7. Connect a 562 Scalar Network Analyzer to the 682XXB/ 683XXB as follows: a. Connect the 682XXB/683XXB AUX I/O to the 562 AUX I/O . b. Connect the 562 DEDICA TED GPIB to the 682XXB/ 683XXB IEEE-488 GPIB . c. Connect the RF Detector to the 562 Channel A Input. Step 8. Set up the 562 Scalar Network Analyzer as follows: a. [...]
-
Page 210
5-44 682XXB/683XXB MM Error 129 Switched Filter or Level Detector Failed Description: Error 129 indicates a failure of either the switched filter or level detector circuitry . The 682XXB/683XXB may or may not pro - duce an RF output in the 2 to 20 GHz frequency range. Thus, there are two troubleshooting paths for this problem—unleveled with outpu[...]
-
Page 211
682XXB/683XXB MM 5-45 Unleveled with no/low output power: Step 1. Set up the 682XXB/683XXB as follows: a. 682XXB Setup: CW/SWEEP SELECT : Step F1: 0.010 GHz F2: 20.000 GHz Number of Steps: 400 L1: +1.00 dBm 683XXB Setup: CW/SWEEP SELECT : Analog F1: 0.010 GHz F2: 20.000 GHz Sweep Time: 0.100 Sec L1: +1.00 dBm b. LEVEL/ALC SELECT : ALC Mode Leveling[...]
-
Page 212
5-46 682XXB/683XXB MM Step 5. Set up the 562 Scalar Network Analyzer as follows: a. Press SYSTEM MENU key . b. From System Menu display , select RESET . c. Press CHANNEL 2 DISPLA Y : OFF . d. Press CHANNEL 1 DISPLA Y : ON. e. Press CHANNEL 1 MENU key . f. From the Channel 1 Menu display , select POWER. Step 6. Using the scalar network analyzer , me[...]
-
Page 213
682XXB/683XXB MM 5-47 TROUBLESHOOTING TROUBLESHOOTING TABLES Error 130 2-3.3 GH Switched Filter Error 131 3.3-5.5 GH Switched Filter Error 132 5.5-8.4 GH Switched Filter Error 133 8.4-13.25 GH Switched Filter Error 134 13.25-20 GH Switched Filter Description: Each of these error messages indicates a failure in a switched filter path within the swit[...]
-
Page 214
5-48 682XXB/683XXB MM TROUBLESHOOTING TROUBLESHOOTING TABLES Error 135 Modulator or Driver Failed Description: Error 135 indicates a failure of the modulator in the switched filter assembly or the modulator driver circuitry on the A9 PIN Control PCB. Step 1. Replace the A9 PCB and run self-test. If error 135 is not displayed, the problem is cleared[...]
-
Page 215
682XXB/683XXB MM 5-49 Output Power Level Related Problems (20 to 40 GHz) 682XXB/683XXB Models with SDM Error 138 SDM Unit or Driver Failed Description: Error 138 indicates a failure of the SDM, a failure of the SDM bias regulator circuitry on the A14 SDM Driver PCB, or a failure of the frequency band selection circuitry on the A12 Analog Instructio[...]
-
Page 216
5-50 682XXB/683XXB MM Error 139 32-40 GHz SDM Section Failed Error 140 25-32 GHz SDM Section Failed Error 141 20-25 GHz SDM Section Failed Description: Each of these error messages indicates a failure in a switched doubler filter path within the SDM. The 682XXB/683XXB will not produce an RF output in the frequency range of the failed switched doubl[...]
-
Page 217
682XXB/683XXB MM 5-51 Error 144 RF was Off when Selftest started. Some tests where not performed Description: Indicates that some self-tests where not performed be - cause the RF Output was selected OFF on the front panel. Step 1. Press the OUTPUT key on the front panel to turn the RF Output ON . Step 2. Run self-test again. T able 5-24. Error Mess[...]
-
Page 218
5-52 682XXB/683XXB MM TROUBLESHOOTING TROUBLESHOOTING TABLES Error 147 Internal FM circuitry failed Description: Indicates a failure of the internal frequency modulation function. The 682XXB/683XXB may or may not provide frequency modulation of the RF output signal using modulating signals from an external source. Step 1. Set up the 682XXB/683XXB a[...]
-
Page 219
682XXB/683XXB MM 5-53/5-54 TROUBLESHOOTING TROUBLESHOOTING TABLES Step 5. Reconnect cable W108 to A5J4 and disconnect cable W121 at A5J5. Step 6. Using the oscilloscope, verify the presence of a 10 MHz TTL signal at the end of cable W121. If present, replace the A5 PCB. If not present, go to step 7. Step 7. Reconnect cable W121 to A5J5 and disconne[...]
-
Page 220
[...]
-
Page 221
T able of Contents 6-1 INTRODUCTION ................... 6-3 6-2 REMOVING AND REPLACING THE CHASSIS COVERS .......................6 - 4 Preliminary ...................6 - 4 Procedure ....................6 - 4 6-3 REMOVING AND REPLACING THE FRONT P ANEL ASSEMBL Y .................6 - 6 Preliminary ...................6 - 6 Procedure ..................[...]
-
Page 222
6-8 REMOVING AND REPLACING THE A16 OR A17 PCB ....................... 6-1 1 Preliminary ................... 6-1 1 Procedure ................... 6-1 1 6-9 REMOVING AND REPLACING THE A18 OR A19 PCB ....................... 6-12 Preliminary .................. 6-12 Procedure ................... 6-12 6-10 REMOVING AND REPLACING THE REAR P ANEL ASSEMBL Y [...]
-
Page 223
Chapter 6 Removal and Replacement Pr ocedur es 6-1 INTRODUCTION This chapter provides procedures for gaining access to the major 682XXB/683XXB assemblies, subassemblies, and components for troubleshooting or replacement. W ARNING Hazardous voltages are present inside the 682XXB/683XXB whenever ac line power is connected. T urn off the unit and remo[...]
-
Page 224
6-2 REMOVING AND REPLACING THE CHASSIS COVERS T roubleshooting procedures require removal of the top cover . Replace - ment of some 682XXB/683XXB assemblies and parts require removal of all covers. The following procedure describes this process. Preliminary Disconnect the power cord from the unit. Procedure Remove and replace the chassis covers as [...]
-
Page 225
Step 12 Remove the screw that fastens the other side cover to the chassis. (The screw is lo - cated at the rear of the instrument.) Step 13 Remove the side cover and set it aside. Step 14 T o replace the chassis covers, reverse the procedure used to remove them. 682XXB/683XXB MM 6-5 (2) (2) Rear Feet (4) (2) T op Cover Side Handle Cover Carrying Ha[...]
-
Page 226
6-3 REMOVING AND REPLACING THE FRONT P ANEL ASSEMBL Y This paragraph provides instructions for removing and replacing the front panel assembly of the 682XXB/683XXB. The front panel assem - bly contains the A1 and A2 Front Panel PCBs. Refer to Figure 6-2 dur - ing this procedure. Preliminary Disconnect the power cord from the unit and remove the cha[...]
-
Page 227
682XXB/683XXB MM 6-7 REMOVAL AND FRONT PANEL ASSEMBLY REPLACEMENT PROCEDURES REMOVAL DIAGRAM Figure 6-2. Front Panel Assembly Removal[...]
-
Page 228
6-4 REMOVING AND REPLACING THE A3, A4, A5, OR A6 PCB This paragraph provides instructions for removing and replacing the A3 Reference Loop PCB, the A4 Coarse Loop PCB, the A5 Fine Loop PCB, or the A6 Pulse Generator PCB, all of which are located in the RF housing (see Figure 6-3). Preliminary Disconnect the power cord from the unit and remove the t[...]
-
Page 229
682XXB/683XXB MM 6-9 REMOVAL AND PCB AND COMPONENT REPLACEMENT PROCEDURES LOCATOR DIAGRAM J1 J2 J3 J4 J5 J6 J7 J1 J2 J3 J4 J5 J6 J7 J 1 J2 J3 J4 J5 J6 J7 J1 J2 J3 J4 J5 J6 J7 T est P oints Rear P anel A15 Regulator PCB A3 A4 A5 A6 A7 A9 A8 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A3 Refere nce Loop PCB A4 Coarse Loop PCB A5 Fine Loop PCB A6 Pulse Ge[...]
-
Page 230
6-5 REMOVING AND REPLACING THE A7 PCB This paragraph provides instructions for removing and replacing the A7 YIG Loop PCB, which is located in the main card cage (see Figure 6-3). Preliminary Disconnect the power cord from the unit and remove the top cover as described in paragraph 6-2. Procedure Remove and replace the A7 PCB as follows: Step 1 Rem[...]
-
Page 231
6-7 REMOVING AND REPLACING THE A13, A14, OR A15 PCB This paragraph provides instructions for removing and replacing the A13 YIG Driver PCB, the A14 SDM, SQM Driver PCB, or the A15 Regulator PCB, all of which are located in the main card cage (see Fig - ure 6-3). Each of these PCB assemblies consists of a PCB and a PCB Heat Sink subassembly . Prelim[...]
-
Page 232
6-9 REMOVING AND REPLACING THE A18 OR A19 PCB This paragraph provides instructions for removing and replacing the A18 Power Supply PCB or the A19 AC Line Conditioner PCB, both of which are located in the power supply housing assembly (see Figure 6-3). Preliminary Disconnect the power cord from the unit and remove the top cover as described in parag[...]
-
Page 233
6-10 REMOVING AND REPLACING THE REAR P ANEL ASSEMBL Y This paragraph provides instructions for removing and replacing the rear panel assembly of the 682XXB/683XXB. The rear panel assembly contains the A21 Line Filter/Rectifier PCB, the A21-1 BNC/AUX I/O Connector PCB, the line module assembly , and the fan assembly . Refer to Figure 6-4 during this[...]
-
Page 234
Step 9 Disconnect the cable assembly from the A21 Line Filter/Rectifier PCB at connec - tor P2 on the A19 PCB. Step 10 Carefully pull the rear panel assembly away from the signal generator chassis until the cable connections to the Mother - board are accessable. Step 1 1 Disconnect the fan cable connector from J13 on the Motherboard. Step 12 Discon[...]
-
Page 235
682XXB/683XXB MM 6-15 REMOVAL AND REAR PANEL ASSEMBLY REPLACEMENT PROCEDURES REMOVAL DIAGRAM Figure 6-4. Rear Panel Assembly Removal[...]
-
Page 236
6-1 1 REMOVING AND REPLACING THE A21 PCB This paragraph provides instructions for removing and replacing the A21 Line Filter/Rectifier PCB, which is located on the rear panel as - sembly (see Figure 6-4). Preliminary Disconnect the power cord from the unit. Remove the chassis covers as described in paragraph 6-2. Remove the rear panel assembly as d[...]
-
Page 237
6-12 REMOVING AND REPLACING THE A21-1 PCB This paragraph provides instructions for removing and replacing the A21-1 BNC/AUX I/O Connector PCB, which is located on the rear panel assembly (see Figure 6-4). Preliminary Disconnect the power cord from the unit. Remove the chassis covers as described in paragraph 6-2. Remove the rear panel assembly as d[...]
-
Page 238
6-13 REMOVING AND REPLACING THE F AN ASSEMBL Y This paragraph provides instructions for removing and replacing the fan assembly , which is located on the rear panel assembly (see Figure 6-4). Preliminary Disconnect the power cord from the unit. Remove the chassis covers as described in paragraph 6-2. Remove the rear panel assembly as described in p[...]
-
Page 239
Appendix A T est Records A-1 INTRODUCTION This appendix provides test records for recording the results of the Performance V erification tests (Chapter 3) and the Calibration proce - dures (Chapter 4). They jointly provide the means for maintaining an accurate and complete record of instrument performance. T est records are provided for all models [...]
-
Page 240
[...]
-
Page 241
ANRITSU Model 68237B/68337B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-3 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) ...[...]
-
Page 242
A-4 682XXB/683XXB MM 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure Fine Loop Test Procedure (Standard 68X37B) T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue ** 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1.00[...]
-
Page 243
682XXB/683XXB MM A-5 3-8 Spurious Signals Test: RF Output Signals <2 GHz This test is not applicable to the 68237B/68337B model. 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz Test Procedure (2 to 10 GHz) Measured V alue Upper Limit Set F1 to 2.1 GHz Record the level of all harmonics of the 2.1 GHz carrier: 4.2 GHz (2nd harmonic) ........[...]
-
Page 244
A-6 682XXB/683XXB MM TEST MODEL RECORD 68237B/68337B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz (Continued) Test Procedure (11 to 20 GHz) Measured V alue Upper Limit Set F1 to 12.4 GHz Record the level of all harmonics of the 12.4 GHz carrier: 24.8 GHz (2nd harmonic) ..................... 37.2 GHz (3rd harmonic) ...................... __[...]
-
Page 245
682XXB/683XXB MM A-7 TEST MODEL RECORD 68237B/68337B 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 2.0 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ............................[...]
-
Page 246
A-8 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Model 68237B/68337B without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set L1 to: Measured Power * +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + 1 dBm _________dBm _________dBm _________dBm __[...]
-
Page 247
682XXB/683XXB MM A-9 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68237B/68337B with Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + 1 dBm + 0 dBm – 1 dBm _________dBm _________dBm ____[...]
-
Page 248
A-10 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68237B/68337B with Option 15B High Power & without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set L1 to: Measured Power * +17 dBm +16 dBm +15 dBm +14 dBm +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5[...]
-
Page 249
682XXB/683XXB MM A-11 3-11 Power Level Accuracy And Flatness Tests (Continued) (Model 68237B/68337B with Option 15B High Power & Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set L1 to: Measured Power * +15 dBm +14 dBm +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm ___[...]
-
Page 250
A-12 682XXB/683XXB MM TEST MODEL RECORD 68237B/68337B 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculat[...]
-
Page 251
682XXB/683XXB MM A-13 TEST MODEL RECORD 68237B/68337B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period)[...]
-
Page 252
A-14 682XXB/683XXB MM TEST MODEL RECORD 68237B/68337B 3-15 Pulse Modulation Test: Video Feedthrough Test Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Set PRI (period) to 0.01 ms Measure and record the Video Feedthrough voltage spikes .... –10 mV _______ mV +10 mV 3-16 Pulse Modulation Test: RF On[...]
-
Page 253
ANRITSU Model 68237B/68337B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-15 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm [...]
-
Page 254
A-16 682XXB/683XXB MM TEST MODEL RECORD 68237B/68337B 4-10 ALC Slope Calibration (68337B having Firmware Version 1.01 to 2.00) Procedure Step Step Completion 5. ALC Slope DAC adjustment for 2 GHz ( This step is not applicable to the 68337B ) ....................... _____N/A ______ 9. ALC Slope DAC adjustment for >2 GHz ..........................[...]
-
Page 255
682XXB/683XXB MM A-17 TEST MODEL RECORD 68237B/68337B 4-13 FM Calibration (68237B/68337B with Firmware Version 1.01 to 2.10) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensi[...]
-
Page 256
A-18 682XXB/683XXB MM 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Calibration (calterm 155) ..........[...]
-
Page 257
ANRITSU Model 68245B/68345B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-19 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... ______________ Record frequency error value (after 24 hours) ...[...]
-
Page 258
A-20 682XXB/683XXB MM TEST MODEL RECORD 68245B/68345B 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure Fine Loop Test Procedure (Standard 68X45B) T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue ** 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.[...]
-
Page 259
682XXB/683XXB MM A-21 3-8 Spurious Signals Test: RF Output Signals £ 2.2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 500 MHz Record the level of all harmonics of the 500 MHz carrier 1.0 GHz (2nd harmonic) ..................... 1.5 GHz (3rd harmonic) ...................... 2.0 GHz (4th harmonic) ...................... 2.5 GHz (5th harm[...]
-
Page 260
A-22 682XXB/683XXB MM 3-9 Harmonic Test: RF Output Signals From 2.2 to 20 GHz Test Procedure (2.2 to 10 GHz) Measured V alue Upper Limit Set F1 to 2.4 GHz Record the level of all harmonics of the 2.4 GHz carrier: 4.8 GHz (2nd harmonic) ..................... 7.2 GHz (3rd harmonic) ...................... 9.6 GHz (4th harmonic) ...................... [...]
-
Page 261
682XXB/683XXB MM A-23 3-9 Harmonic Test: RF Output Signals From 2.2 to 20 GHz (Continued) Test Procedure (11 to 20 GHz) Measured V alue Upper Limit Set F1 to 12.4 GHz Record the level of all harmonics of the 12.4 GHz carrier: 24.8 GHz (2nd harmonic) ..................... 37.2 GHz (3rd harmonic) ...................... _______________dBc ____________[...]
-
Page 262
A-24 682XXB/683XXB MM 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. _______________dBc _________[...]
-
Page 263
682XXB/683XXB MM A-25 3-11 Power Level Accuracy and Flatness Tests (Model 68245B/68345B without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + [...]
-
Page 264
A-26 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68245B/68345B with Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + 1 dBm +[...]
-
Page 265
682XXB/683XXB MM A-27 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68245B/68345B with Option 15B High Power & without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 d[...]
-
Page 266
A-28 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68245B/68345B with Option 15B High Power & Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 d[...]
-
Page 267
682XXB/683XXB MM A-29 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculate and record the actual AM input[...]
-
Page 268
A-30 682XXB/683XXB MM 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period) ............................. O[...]
-
Page 269
682XXB/683XXB MM A-31 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Record the displayed output level L1 (step 5.b) .................... Record the displayed output level L1 [...]
-
Page 270
A-32 682XXB/683XXB MM 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents an On/Off Ratio of >80 dB.) . 60 dB [...]
-
Page 271
ANRITSU Model 68245B/68345B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-33 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm [...]
-
Page 272
A-34 682XXB/683XXB MM 4-10 ALC Slope Calibration (68345B having Firmware Version 1.00 and above) Procedure Step Step Completion 5. ALC Slope DAC adjustment ................................ ______________ 6. Store the DAC setting value(s) ............................... ______________ TEST MODEL RECORD 68245B/68345B 4-9 RF Level Calibration This cal[...]
-
Page 273
682XXB/683XXB MM A-35 4-13 FM Calibration (68245B/68345B with Firmware Version 1.00) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensitivity Calibration (calterm 124) .......[...]
-
Page 274
A-36 682XXB/683XXB MM TEST MODEL RECORD 68245B/68345B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cali[...]
-
Page 275
ANRITSU Model 68247B/68347B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-37 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... ______________ Record frequency error value (after 24 hours) ...[...]
-
Page 276
A-38 682XXB/683XXB MM TEST MODEL RECORD 68247B/68347B 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure Fine Loop Test Procedure (Standard 68X47B) T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue ** 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.[...]
-
Page 277
682XXB/683XXB MM A-39 3-8 Spurious Signals Test: RF Output Signals <2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 10 MHz Record the presence of the worst case harmonic .......... Record the presence of the worst case non-harmonic ....... _______________dBc _______________dBc –30 dBc –40 dBc Set F1 to 20 MHz Record the presence o[...]
-
Page 278
A-40 682XXB/683XXB MM TEST MODEL RECORD 68247B/68347B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz Test Procedure (2 to 10 GHz) Measured V alue Upper Limit Set F1 to 2.1 GHz Record the level of all harmonics of the 2.1 GHz carrier: 4.2 GHz (2nd harmonic) ..................... 6.3 GHz (3rd harmonic) ...................... 8.4 GHz (4th harmo[...]
-
Page 279
682XXB/683XXB MM A-41 TEST MODEL RECORD 68247B/68347B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz (Continued) Test Procedure (11 to 20 GHz) Measured V alue Upper Limit Set F1 to 12.4 GHz Record the level of all harmonics of the 12.4 GHz carrier: 24.8 GHz (2nd harmonic) ..................... 37.2 GHz (3rd harmonic) ...................... _[...]
-
Page 280
A-42 682XXB/683XXB MM TEST MODEL RECORD 68247B/68347B 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ...........................[...]
-
Page 281
682XXB/683XXB MM A-43 3-11 Power Level Accuracy and Flatness Tests (Model 68247B/68347B without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + [...]
-
Page 282
A-44 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68247B/68347B with Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + 1 dBm +[...]
-
Page 283
682XXB/683XXB MM A-45 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68247B/68347B with Option 15B High Power & without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 d[...]
-
Page 284
A-46 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68247B/68347B with Option 15B High Power & Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 d[...]
-
Page 285
682XXB/683XXB MM A-47 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculate and record the actual AM input[...]
-
Page 286
A-48 682XXB/683XXB MM TEST MODEL RECORD 68247B/68347B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period)[...]
-
Page 287
682XXB/683XXB MM A-49 TEST MODEL RECORD 68247B/68347B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Record the displayed output level L1 (step 5.b) .................... Recor[...]
-
Page 288
A-50 682XXB/683XXB MM TEST MODEL RECORD 68247B/68347B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents an On/O[...]
-
Page 289
ANRITSU Model 68247B/68347B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-51 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm [...]
-
Page 290
A-52 682XXB/683XXB MM TEST MODEL RECORD 68247B/68347B 4-10 ALC Slope Calibration (68347B having Firmware Version 1.01 to 2.00) Procedure Step Step Completion 5. ALC Slope DAC adjustment for 2 GHz ......................... ______________ 9. ALC Slope DAC adjustment for >2 GHz .......................... ______________ 10. Store the DAC setting[...]
-
Page 291
682XXB/683XXB MM A-53 TEST MODEL RECORD 68247B/68347B 4-13 FM Calibration (68247B/68347B with Firmware Version 1.01 to 2.10) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensi[...]
-
Page 292
A-54 682XXB/683XXB MM TEST MODEL RECORD 68247B/68347B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cali[...]
-
Page 293
ANRITSU Model 68253B/68353B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-55 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) ..[...]
-
Page 294
A-56 682XXB/683XXB MM 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1.000 000 000 12.000 000 000 13.000 000 000 14.[...]
-
Page 295
682XXB/683XXB MM A-57 TEST MODEL RECORD 68253B/68353B 3-7 Frequency Synthesis Tests Fine Loop Test Procedure (Standard 68X53B) Fine Loop Test Procedure (68X53B with Option 11) T est Frequency (in GHz) Measured V alue ** T est Frequency (in GHz) Measured Value *** 2.000 001 000 2.000 002 000 2.000 003 000 2.000 004 000 2.000 005 000 2.000 006 000 2.[...]
-
Page 296
A-58 682XXB/683XXB MM TEST MODEL RECORD 68253B/68353B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz Test Procedure (2 to 10 GHz) Measured V alue Upper Limit Set F1 to 2.1 GHz Record the level of all harmonics of the 2.1 GHz carrier: 4.2 GHz (2nd harmonic) ..................... 6.3 GHz (3rd harmonic) ...................... 8.4 GHz (4th harmo[...]
-
Page 297
682XXB/683XXB MM A-59 TEST MODEL RECORD 68253B/68353B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz (Continued) Test Procedure (11 to 20 GHz) Measured V alue Upper Limit Set F1 to 12.4 GHz Record the level of all harmonics of the 12.4 GHz carrier: 24.8 GHz (2nd harmonic) ..................... 37.2 GHz (3rd harmonic) ...................... _[...]
-
Page 298
A-60 682XXB/683XXB MM TEST MODEL RECORD 68253B/68353B 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 2.0 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ...........................[...]
-
Page 299
682XXB/683XXB MM A-61 TEST MODEL RECORD 68253B/68353B 3-11 Power Level Accuracy and Flatness Tests (Model 68253B/68353B without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + [...]
-
Page 300
A-62 682XXB/683XXB MM TEST MODEL RECORD 68253B/68353B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68253B/68353B with Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + 1 dBm +[...]
-
Page 301
682XXB/683XXB MM A-63 TEST MODEL RECORD 68253B/68353B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68253B/68353B with Option 15B High Power & without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 1 [...]
-
Page 302
A-64 682XXB/683XXB MM TEST MODEL RECORD 68253B/68353B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68253B/68353B with Option 15B High Power & Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8 [...]
-
Page 303
682XXB/683XXB MM A-65 TEST MODEL RECORD 68253B/68353B 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculat[...]
-
Page 304
A-66 682XXB/683XXB MM TEST MODEL RECORD 68253B/68353B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period)[...]
-
Page 305
682XXB/683XXB MM A-67/A-68 TEST MODEL RECORD 68253B/68353B 3-15 Pulse Modulation Test: Video Feedthrough Test Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Set PRI (period) to 0.01 ms Measure and record the Video Feedthrough voltage spikes .... –10 mV _______ mV +10 mV 3-16 Pulse Modulation Test: [...]
-
Page 306
[...]
-
Page 307
ANRITSU Model 68253B/68353B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-69 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm [...]
-
Page 308
A-70 682XXB/683XXB MM TEST MODEL RECORD 68253B/68353B 4-10 ALC Slope Calibration (68353B having Firmware Version 1.01 to 2.00) Procedure Step Step Completion 5. ALC Slope DAC adjustment for 2 GHz ( This step is not applicable to the 68353B) ....................... _____N/A ______ 9. ALC Slope DAC adjustment for >2 GHz .......................... [...]
-
Page 309
682XXB/683XXB MM A-71 TEST MODEL RECORD 68253B/68353B 4-13 FM Calibration (68253B/68353B with Firmware Version 1.01 to 2.10) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensi[...]
-
Page 310
A-72 682XXB/683XXB MM TEST MODEL RECORD 68253B/68353B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cali[...]
-
Page 311
ANRITSU Model 68255B/68355B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-73 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) ..[...]
-
Page 312
A-74 682XXB/683XXB MM 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1.000 000 000 12.000 000 000 13.0[...]
-
Page 313
682XXB/683XXB MM A-75 3-7 Frequency Synthesis Tests Fine Loop Test Procedure (Standard 68X55B) Fine Loop Test Procedure (68X55B with Option 11) T est Frequency (in GHz) Measured V alue ** T est Frequency (in GHz) Measured V alue *** 1.000 001 000 1.000 002 000 1.000 003 000 1.000 004 000 1.000 005 000 1.000 006 000 1.000 007 000 1.000 008 000 1.000[...]
-
Page 314
A-76 682XXB/683XXB MM 3-8 Spurious Signals Test: RF Output Signals £ 2.2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 500 MHz Record the level of all harmonics of the 500 MHz carrier 1.0 GHz (2nd harmonic) ..................... 1.5 GHz (3rd harmonic) ...................... 2.0 GHz (4th harmonic) ...................... 2.5 GHz (5th harm[...]
-
Page 315
682XXB/683XXB MM A-77 3-9 Harmonic Test: RF Output Signals From 2.2 to 20 GHz Test Procedure (2.2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.4 GHz Record the level of all harmonics of the 2.4 GHz carrier: 4.8 GHz (2nd harmonic) ..................... 7.2 GHz (3rd harmonic) ...................... 9.6 GHz (4th harmonic) ...................... 1[...]
-
Page 316
A-78 682XXB/683XXB MM Test Procedure (11 to 20 GHz) Measure V alue Upper Limit Set F1 to 12.4 GHz Record the level of all harmonics of the 12.4 GHz carrier: 24.8 GHz (2nd harmonic) ..................... 37.2 GHz (3rd harmonic) ...................... _______________dBc _______________dBc –60 dBc* –60 dBc* Set F1 to 16.0 GHz Record the level of a[...]
-
Page 317
682XXB/683XXB MM A-79 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 6.0 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. _______________d[...]
-
Page 318
A-80 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Model 68255B/68355B without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7[...]
-
Page 319
682XXB/683XXB MM A-81 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68255B/68355B with Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm + [...]
-
Page 320
A-82 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68255B/68355B with Option 15B High Power & without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm[...]
-
Page 321
682XXB/683XXB MM A-83 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68255B/68355B with Option 15B High Power & Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dB[...]
-
Page 322
A-84 682XXB/683XXB MM 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculate and record the actual AM input[...]
-
Page 323
682XXB/683XXB MM A-85 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period) ............................. O[...]
-
Page 324
A-86 682XXB/683XXB MM 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Record the displayed output level L1 (step 5.b) .................... Record the displayed output level L1 [...]
-
Page 325
682XXB/683XXB MM A-87/A-88 TEST MODEL RECORD 68255B/68355B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents an[...]
-
Page 326
[...]
-
Page 327
ANRITSU Model 68255B/68355B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-89 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm [...]
-
Page 328
A-90 682XXB/683XXB MM 4-10 ALC Slope Calibration (68355B having Firmware Version 1.00 and above) Procedure Step Step Completion 5. ALC Slope DAC adjustment ................................ ______________ 6. Store the DAC setting value(s) ............................... ______________ TEST MODEL RECORD 68255B/68355B 4-9 RF Level Calibration This cal[...]
-
Page 329
682XXB/683XXB MM A-91 4-13 FM Calibration (68255B/68355B with Firmware Version 1.00) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensitivity Calibration (calterm 124) .......[...]
-
Page 330
A-92 682XXB/683XXB MM TEST MODEL RECORD 68255B/68355B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide Μ Μοδε Σενσιτιϖιτψ Χαλιβρατιον (χαλτερµ 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... _________[...]
-
Page 331
ANRITSU Model 68259B/68359B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-93 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) ..[...]
-
Page 332
A-94 682XXB/683XXB MM TEST MODEL RECORD 68259B/68359B 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1[...]
-
Page 333
682XXB/683XXB MM A-95 TEST MODEL RECORD 68259B/68359B 3-7 Frequency Synthesis Tests Fine Loop Test Procedure (Standard 68X59B) Fine Loop Test Procedure (68X59B with Option 11) T est Frequency (in GHz) Measured V alue ** T est Frequency (in GHz) Measured V alue *** 1.000 001 000 1.000 002 000 1.000 003 000 1.000 004 000 1.000 005 000 1.000 006 000 1[...]
-
Page 334
A-96 682XXB/683XXB MM 3-8 Spurious Signals Test: RF Output Signals <2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 10 MHz Record the presence of the worst case harmonic .......... Record the presence of the worst case non-harmonic ....... _______________dBc _______________dBc –30 dBc –40 dBc Set F1 to 20 MHz Record the presence o[...]
-
Page 335
682XXB/683XXB MM A-97 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz Test Procedure (2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.1 GHz Record the level of all harmonics of the 2.1 GHz carrier: 4.2 GHz (2nd harmonic) ..................... 6.3 GHz (3rd harmonic) ...................... 8.4 GHz (4th harmonic) ...................... 10.5 [...]
-
Page 336
A-98 682XXB/683XXB MM 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. _______________dBc _________[...]
-
Page 337
682XXB/683XXB MM A-99 TEST MODEL RECORD 68259B/68359B 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 6.0 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ...............[...]
-
Page 338
A-100 682XXB/683XXB MM TEST MODEL RECORD 68259B/68359B 3-11 Power Level Accuracy and Flatness Tests (Model 68259B/68359B without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 [...]
-
Page 339
682XXB/683XXB MM A-101 TEST MODEL RECORD 68259B/68359B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68259B/68359B with Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +[...]
-
Page 340
A-102 682XXB/683XXB MM TEST MODEL RECORD 68259B/68359B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68259B/68359B with Option 15B High Power & without Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Se[...]
-
Page 341
682XXB/683XXB MM A-103 TEST MODEL RECORD 68259B/68359B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68259B/68359B with Option 15B High Power & Option 2A Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 22.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to:[...]
-
Page 342
A-104 682XXB/683XXB MM TEST MODEL RECORD 68259B/68359B 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calcula[...]
-
Page 343
682XXB/683XXB MM A-105 TEST MODEL RECORD 68259B/68359B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period[...]
-
Page 344
A-106 682XXB/683XXB MM TEST MODEL RECORD 68259B/68359B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Record the displayed output level L1 (step 5.b) .................... Reco[...]
-
Page 345
682XXB/683XXB MM A-107/A-108 TEST MODEL RECORD 68259B/68359B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents [...]
-
Page 346
[...]
-
Page 347
ANRITSU Model 68259B/68359B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-109 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 348
A-110 682XXB/683XXB MM TEST MODEL RECORD 68259B/68359B 4-10 ALC Slope Calibration (68359B having Firmware Version 1.01 to 2.00) Procedure Step Step Completion 5. ALC Slope DAC adjustment for 2 GHz ......................... ______________ 9. ALC Slope DAC adjustment for >2 GHz .......................... ______________ 10. Store the DAC settin[...]
-
Page 349
682XXB/683XXB MM A-111 4-13 FM Calibration (68259B/68359B with Firmware Version 1.01 to 2.10) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensitivity Calibration (calterm 124[...]
-
Page 350
A-112 682XXB/683XXB MM TEST MODEL RECORD 68259B/68359B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 351
ANRITSU Model 68263B/68363B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-113 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) .[...]
-
Page 352
A-114 682XXB/683XXB MM TEST MODEL RECORD 68263B/68363B 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1.000 000 000 [...]
-
Page 353
682XXB/683XXB MM A-115 TEST MODEL RECORD 68263B/68363B 3-7 Frequency Synthesis Tests Fine Loop Test Procedure (Standard 68X63B) Fine Loop Test Procedure (68X63Bwith Option 11) T est Frequency (in GHz) Measured V alue ** T est Frequency (in GHz) Measured V alue *** 2.000 001 000 2.000 002 000 2.000 003 000 2.000 004 000 2.000 005 000 2.000 006 000 2[...]
-
Page 354
A-116 682XXB/683XXB MM TEST MODEL RECORD 68263B/68363B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz Test Procedure (2 to 10 GHz) Measured V alue Upper Limit Set F1 to 2.1 GHz Record the level of all harmonics of the 2.1 GHz carrier: 4.2 GHz (2nd harmonic) ..................... 6.3 GHz (3rd harmonic) ...................... 8.4 GHz (4th harm[...]
-
Page 355
682XXB/683XXB MM A-117 TEST MODEL RECORD 68263B/68363B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz (Continued) Test Procedure (11 to 20 GHz) Measured V alue Upper Limit Set F1 to 12.4 GHz Record the level of all harmonics of the 12.4 GHz carrier: 24.8 GHz (2nd harmonic) ..................... 37.2 GHz (3rd harmonic) ...................... [...]
-
Page 356
A-118 682XXB/683XXB MM TEST MODEL RECORD 68263B/68363B 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 2.0 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ..........................[...]
-
Page 357
682XXB/683XXB MM A-119 TEST MODEL RECORD 68263B/68363B 3-11 Power Level Accuracy and Flatness Tests (Model 68263B/68363B without Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm +[...]
-
Page 358
A-120 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68263B/68363B with Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + 1 dBm + 0 dBm – 1 dBm – 2 dBm – [...]
-
Page 359
682XXB/683XXB MM A-121 TEST MODEL RECORD 68263B/68363B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68263B/68363B with Option 15B High Power & without Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 1[...]
-
Page 360
A-122 682XXB/683XXB MM TEST MODEL RECORD 68263B/68363B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68263B/68363B with Option 15B High Power & Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8[...]
-
Page 361
682XXB/683XXB MM A-123 TEST MODEL RECORD 68263B/68363B 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calcula[...]
-
Page 362
A-124 682XXB/683XXB MM TEST MODEL RECORD 68263B/68363B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period[...]
-
Page 363
682XXB/683XXB MM A-125/A-126 TEST MODEL RECORD 68263B/68363B 3-15 Pulse Modulation Test: Video Feedthrough Test Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Set PRI (period) to 0.01 ms Measure and record the Video Feedthrough voltage spikes .... –10 mV _______ mV +10 mV 3-16 Pulse Modulation Test[...]
-
Page 364
[...]
-
Page 365
ANRITSU Model 68263B/68363B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-127 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 366
A-128 682XXB/683XXB MM TEST MODEL RECORD 68263B/68363B 4-10 ALC Slope Calibration (68363B having Firmware Version 1.01 to 2.00) Procedure Step Step Completion 5. ALC Slope DAC adjustment for 2 GHz ( This step is not applicable to the 68363B ) ....................... _____N/A ______ 9. ALC Slope DAC adjustment for >2 GHz .........................[...]
-
Page 367
682XXB/683XXB MM A-129 TEST MODEL RECORD 68263B/68363B 4-13 FM Calibration (68263B/68363B with Firmware Version 1.01 to 2.10) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sens[...]
-
Page 368
A-130 682XXB/683XXB MM TEST MODEL RECORD 68263B/68363B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 369
ANRITSU Model 68265B/68365B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-131 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) .[...]
-
Page 370
A-132 682XXB/683XXB MM 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1.000 000 000 12.000 000 000 13.[...]
-
Page 371
682XXB/683XXB MM A-133 3-7 Frequency Synthesis Tests Fine Loop Test Procedure (Standard 68X65B) Fine Loop Test Procedure (68X65B with Option 11) T est Frequency (in Ghz) Measured Value ** T est Frequency (in Ghz) Measured V alue *** 1.000 001 000 1.000 002 000 1.000 003 000 1.000 004 000 1.000 005 000 1.000 006 000 1.000 007 000 1.000 008 000 1.000[...]
-
Page 372
A-134 682XXB/683XXB MM 3-8 Spurious Signals Test: RF Output Signals £ 2.2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 500 MHz Record the level of all harmonics of the 500 MHz carrier 1.0 GHz (2nd harmonic) ..................... 1.5 GHz (3rd harmonic) ...................... 2.0 GHz (4th harmonic) ...................... 2.5 GHz (5th har[...]
-
Page 373
682XXB/683XXB MM A-135 3-9 Harmonic Test: RF Output Signals From 2.2 to 20 GHz Test Procedure (2.2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.4 GHz Record the level of all harmonics of the 2.4 GHz carrier: 4.8 GHz (2nd harmonic) ..................... 7.2 GHz (3rd harmonic) ...................... 9.6 GHz (4th harmonic) ...................... [...]
-
Page 374
A-136 682XXB/683XXB MM 3-9 Harmonic Test: RF Output Signals From 2.2 to 20 GHz (Continued) Test Procedure (11 to 20 GHz) Measure V alue Upper Limit Set F1 to 12.4 GHz Record the level of all harmonics of the 12.4 GHz carrier: 24.8 GHz (2nd harmonic) ..................... 37.2 GHz (3rd harmonic) ...................... _______________dBc ____________[...]
-
Page 375
682XXB/683XXB MM A-137 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 6.0 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. _______________[...]
-
Page 376
A-138 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Model 68265B/68365B without Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + [...]
-
Page 377
682XXB/683XXB MM A-139 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68265B/68365B with Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm +[...]
-
Page 378
A-140 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68265B/68365B with Option 15B High Power & without Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dB[...]
-
Page 379
682XXB/683XXB MM A-141 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68265B/68365B with Option 15B High Power & Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 d[...]
-
Page 380
A-142 682XXB/683XXB MM 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculate and record the actual AM inpu[...]
-
Page 381
682XXB/683XXB MM A-143 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period) ............................. [...]
-
Page 382
A-144 682XXB/683XXB MM 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Record the displayed output level L1 (step 5.b) .................... Record the displayed output level L1[...]
-
Page 383
682XXB/683XXB MM A-145/A-146 TEST MODEL RECORD 68265B/68365B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents [...]
-
Page 384
[...]
-
Page 385
ANRITSU Model 68265B/68365B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-147 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 386
A-148 682XXB/683XXB MM 4-10 ALC Slope Calibration (68365B having Firmware Version 1.00 and above) Procedure Step Step Completion 5. ALC Slope DAC adjustment ................................ ______________ 6. Store the DAC setting value(s) ............................... ______________ TEST MODEL RECORD 68265B/68365B 4-9 RF Level Calibration This ca[...]
-
Page 387
682XXB/683XXB MM A-149 4-13 FM Calibration (68265B/68365B with Firmware Version 1.00) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensitivity Calibration (calterm 124) ......[...]
-
Page 388
A-150 682XXB/683XXB MM TEST MODEL RECORD 68265B/68365B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 389
ANRITSU Model 68269B/68369B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-151 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) .[...]
-
Page 390
A-152 682XXB/683XXB MM TEST MODEL RECORD 68269B/68369B 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 [...]
-
Page 391
682XXB/683XXB MM A-153 TEST MODEL RECORD 68269B/68369B 3-7 Frequency Synthesis Tests Fine Loop Test Procedure (Standard 68X69B) Fine Loop Test Procedure (68X69B with Option 11) T est Frequency (in Ghz) Measured V alue ** T est Frequency (in Ghz) Measured V alue *** 1.000 001 000 1.000 002 000 1.000 003 000 1.000 004 000 1.000 005 000 1.000 006 000 [...]
-
Page 392
A-154 682XXB/683XXB MM TEST MODEL RECORD 68269B/68369B 3-8 Spurious Signals Test: RF Output Signals <2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 10 MHz Record the presence of the worst case harmonic .......... Record the presence of the worst case non-harmonic ....... _______________dBc _______________dBc –30 dBc –40 dBc Set F[...]
-
Page 393
682XXB/683XXB MM A-155 TEST MODEL RECORD 68269B/68369B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz Test Procedure (2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.1 GHz Record the level of all harmonics of the 2.1 GHz carrier: 4.2 GHz (2nd harmonic) ..................... 6.3 GHz (3rd harmonic) ...................... 8.4 GHz (4th harmo[...]
-
Page 394
A-156 682XXB/683XXB MM TEST MODEL RECORD 68269B/68369B 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ..........................[...]
-
Page 395
682XXB/683XXB MM A-157 TEST MODEL RECORD 68269B/68369B 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 6.0 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ..............[...]
-
Page 396
A-158 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Model 68269B/68369B without Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +13 dBm +12 dBm +1 1 dBm +10 dBm + 9 dBm + 8 dBm + [...]
-
Page 397
682XXB/683XXB MM A-159 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68269B/68369B with Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +1 1 dBm +10 dBm + 9 dBm + 8 dBm + 7 dBm +[...]
-
Page 398
A-160 682XXB/683XXB MM TEST MODEL RECORD 68269B/68369B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68269B/68369B with Option 15B High Power & without Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Se[...]
-
Page 399
682XXB/683XXB MM A-161 TEST MODEL RECORD 68269B/68369B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68269B/68369B with Option 15B High Power & Option 2B Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 1.0 GHz Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to:[...]
-
Page 400
A-162 682XXB/683XXB MM TEST MODEL RECORD 68269B/68369B 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calcula[...]
-
Page 401
682XXB/683XXB MM A-163 TEST MODEL RECORD 68269B/68369B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period[...]
-
Page 402
A-164 682XXB/683XXB MM TEST MODEL RECORD 68269B/68369B 3-15 Pulse Modulation Test: Video Feedthrough Test Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Set PRI (period) to 0.01 ms Measure and record the Video Feedthrough voltage spikes .... –10 mV _______ mV +10 mV 3-14 Pulse Modulation Tests: Ris[...]
-
Page 403
682XXB/683XXB MM A-165/A-166 TEST MODEL RECORD 68269B/68369B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents [...]
-
Page 404
[...]
-
Page 405
ANRITSU Model 68269B/68369B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-167 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 406
A-168 682XXB/683XXB MM TEST MODEL RECORD 68269B/68369B 4-10 ALC Slope Calibration (68369B having Firmware Version 1.01 to 2.00) Procedure Step Step Completion 5. ALC Slope DAC adjustment for 2 GHz .......................... ______________ 9. ALC Slope DAC adjustment for >2 GHz .......................... ______________ 10. Store the DAC setting v[...]
-
Page 407
682XXB/683XXB MM A-169 TEST MODEL RECORD 68269B/68369B 4-13 FM Calibration (68269B/68369B with Firmware Version 1.01 to 2.10) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sens[...]
-
Page 408
A-170 682XXB/683XXB MM TEST MODEL RECORD 68269B/68369B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 409
ANRITSU Model 68275B/68375B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-171 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) .[...]
-
Page 410
A-172 682XXB/683XXB MM TEST MODEL RECORD 68275B/68375B 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 [...]
-
Page 411
682XXB/683XXB MM A-173 3-7 Frequency Synthesis Tests Fine Loop Test Procedure (Standard 68X75B) Fine Loop Test Procedure (68X75B with Option 11) T est Frequency (in Ghz) Measured V alue ** T est Frequency (in Ghz) Measured V alue *** 1.000 001 000 1.000 002 000 1.000 003 000 1.000 004 000 1.000 005 000 1.000 006 000 1.000 007 000 1.000 008 000 1.00[...]
-
Page 412
A-174 682XXB/683XXB MM 3-8 Spurious Signals Test: RF Output Signals £ 2.2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 500 MHz Record the level of all harmonics of the 500 MHz carrier 1.0 GHz (2nd harmonic) ..................... 1.5 GHz (3rd harmonic) ...................... 2.0 GHz (4th harmonic) ...................... 2.5 GHz (5th har[...]
-
Page 413
682XXB/683XXB MM A-175 3-9 Harmonic Test: RF Output Signals From 2.2 to 20 GHz Test Procedure (2.2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.4 GHz Record the level of all harmonics of the 2.4 GHz carrier: 4.8 GHz (2nd harmonic) ..................... 7.2 GHz (3rd harmonic) ...................... 9.6 GHz (4th harmonic) ...................... [...]
-
Page 414
A-176 682XXB/683XXB MM 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. _______________dBc ________[...]
-
Page 415
682XXB/683XXB MM A-177 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 26.5 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. ______________[...]
-
Page 416
A-178 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Model 68275B/68375B without Option 2C Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 45.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + [...]
-
Page 417
682XXB/683XXB MM A-179 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68275B/68375B with Option 2C Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 45.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * + 8.5 dBm + 7.5 dBm + 6.5 dBm + 5.5 dBm +[...]
-
Page 418
A-180 682XXB/683XXB MM 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculate and record the actual AM inpu[...]
-
Page 419
682XXB/683XXB MM A-181 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period) ............................. [...]
-
Page 420
A-182 682XXB/683XXB MM 3-15 Pulse Modulation Test: Video Feedthrough Test Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Set PRI (period) to 0.01 ms Measure and record the Video Feedthrough voltage spikes .... –10 mV _______ mV +10 mV 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, an[...]
-
Page 421
682XXB/683XXB MM A-183/A-184 TEST MODEL RECORD 68275B/68375B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents [...]
-
Page 422
[...]
-
Page 423
ANRITSU Model 68275B/68375B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-185 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 424
A-186 682XXB/683XXB MM 4-10 ALC Slope Calibration (68375B having Firware Version 1.00 and above) Procedure Step Step Completion 5. ALC Slope DAC adjustment ................................ ______________ 6. Store the DAC setting value(s) ............................... ______________ 4-9 RF Level Calibration This calibration is performed using an a[...]
-
Page 425
682XXB/683XXB MM A-187 4-13 FM Calibration (68275B/68375B with Firmware Version 1.00) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensitivity Calibration (calterm 124) ......[...]
-
Page 426
A-188 682XXB/683XXB MM TEST MODEL RECORD 68275B/68375B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 427
ANRITSU Model 68277B/68377B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-189 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) .[...]
-
Page 428
A-190 682XXB/683XXB MM 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1.000 000 000 12.000 000 000 13.[...]
-
Page 429
682XXB/683XXB MM A-191 TEST MODEL RECORD 68277B/68377B 3-7 Frequency Synthesis Tests Fine Loop Test Procedure (Standard 68X77B) Fine Loop Test Procedure (68X77B with Option 11) T est Frequency (in Ghz) Measured V alue ** T est Frequency (in Ghz) Measured V alue *** 1.000 001 000 1.000 002 000 1.000 003 000 1.000 004 000 1.000 005 000 1.000 006 000 [...]
-
Page 430
A-192 682XXB/683XXB MM TEST MODEL RECORD 68277B/68377B 3-8 Spurious Signals Test: RF Output Signals <2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 10 MHz Record the presence of the worst case harmonic .......... Record the presence of the worst case non-harmonic ....... _______________dBc _______________dBc –30 dBc –40 dBc Set F[...]
-
Page 431
682XXB/683XXB MM A-193 TEST MODEL RECORD 68277B/68377B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz Test Procedure (2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.1 GHz Record the level of all harmonics of the 2.1 GHz carrier: 4.2 GHz (2nd harmonic) ..................... 6.3 GHz (3rd harmonic) ...................... 8.4 GHz (4th harmo[...]
-
Page 432
A-194 682XXB/683XXB MM TEST MODEL RECORD 68277B/68377B 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ..........................[...]
-
Page 433
682XXB/683XXB MM A-195 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 26.5 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. ______________[...]
-
Page 434
A-196 682XXB/683XXB MM TEST MODEL RECORD 68277B/68377B 3-11 Power Level Accuracy and Flatness Tests (Model 68277B/68377B without Option 2C Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 45.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +10 dBm + 9 dBm + [...]
-
Page 435
682XXB/683XXB MM A-197 TEST MODEL RECORD 68277B/68377B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68277B/68377B with Option 2C Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 45.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * + 8.5 dBm[...]
-
Page 436
A-198 682XXB/683XXB MM 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculate and record the actual AM inpu[...]
-
Page 437
682XXB/683XXB MM A-199 TEST MODEL RECORD 68277B/68377B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period[...]
-
Page 438
A-200 682XXB/683XXB MM TEST MODEL RECORD 68277B/68377B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured Value Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 µ s Record the displayed output level L1 (step 5.b) .................... Re[...]
-
Page 439
682XXB/683XXB MM A-201/A-202 TEST MODEL RECORD 68277B/68377B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents [...]
-
Page 440
[...]
-
Page 441
ANRITSU Model 68277B/68377B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-203 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 442
A-204 682XXB/683XXB MM TEST MODEL RECORD 68277B/68377B 4-10 ALC Slope Calibration (68377B having Firmware Version 1.01 to 2.00) Procedure Step Step Completion 5. ALC Slope DAC adjustment for 2 GHz .......................... ______________ 9. ALC Slope DAC adjustment for >2 GHz .......................... ______________ 10. Store the DAC setting v[...]
-
Page 443
682XXB/683XXB MM A-205 TEST MODEL RECORD 68277B/68377B 4-13 FM Calibration (68277B/68377B with Firmware Version 1.01 to 2.10) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sens[...]
-
Page 444
A-206 682XXB/683XXB MM TEST MODEL RECORD 68277B/68377B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 445
ANRITSU Model 68285B/68385B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-207 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) .[...]
-
Page 446
A-208 682XXB/683XXB MM TEST MODEL RECORD 68285B/68385B 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured Value * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1[...]
-
Page 447
682XXB/683XXB MM A-209 3-7 Frequency Synthesis Tests (Continued) Coarse Loop/YIG Loop Test Procedure (Continued) T est Frequency (in GHz) Measured Value * T est Frequency (in GHz) Measured V alue * 51.000 000 000 52.000 000 000 53.000 000 000 54.000 000 000 55.000 000 000 _____________________ _____________________ _____________________ ___________[...]
-
Page 448
A-210 682XXB/683XXB MM 3-8 Spurious Signals Test: RF Output Signals £ 2.2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 500 MHz Record the level of all harmonics of the 500 MHz carrier 1.0 GHz (2nd harmonic) ..................... 1.5 GHz (3rd harmonic) ...................... 2.0 GHz (4th harmonic) ...................... 2.5 GHz (5th har[...]
-
Page 449
682XXB/683XXB MM A-211 3-9 Harmonic Test: RF Output Signals From 2.2 to 20 GHz Test Procedure (2.2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.4 GHz Record the level of all harmonics of the 2.4 GHz carrier: 4.8 GHz (2nd harmonic) ..................... 7.2 GHz (3rd harmonic) ...................... 9.6 GHz (4th harmonic) ...................... [...]
-
Page 450
A-212 682XXB/683XXB MM 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. _______________dBc ________[...]
-
Page 451
682XXB/683XXB MM A-213 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 26.5 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. ______________[...]
-
Page 452
A-214 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Model 68285B/68385B without Option 2D Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 55.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + [...]
-
Page 453
682XXB/683XXB MM A-215 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68285B/68385B with Option 2D Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 55.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * + 8.5 dBm + 7.5 dBm + 6.5 dBm + 5.5 dBm +[...]
-
Page 454
A-216 682XXB/683XXB MM 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculate and record the actual AM inpu[...]
-
Page 455
682XXB/683XXB MM A-217 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period) ............................. [...]
-
Page 456
A-218 682XXB/683XXB MM 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Record the displayed output level L1 (step 5.b) .................... Record the displayed output level L1[...]
-
Page 457
682XXB/683XXB MM A-219/A-220 TEST MODEL RECORD 68285B/68385B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents [...]
-
Page 458
[...]
-
Page 459
ANRITSU Model 68285B/68385B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-221 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 460
A-222 682XXB/683XXB MM 4-9 RF Level Calibration This calibration is performed using an automatic test system. Contact ANRITSU Customer Service for further information. 4-10 ALC Slope Calibration (68385B having Firmware Version 1.00 and above) Procedure Step Step Completion 5. ALC Slope DAC adjustment ................................ ______________ [...]
-
Page 461
682XXB/683XXB MM A-223 4-13 FM Calibration (68285B/68385B with Firmware Version 1.00) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensitivity Calibration (calterm 124) ......[...]
-
Page 462
A-224 682XXB/683XXB MM TEST MODEL RECORD 68285B/68385B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 463
ANRITSU Model 68287B/68387B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-225 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) .[...]
-
Page 464
A-226 682XXB/683XXB MM TEST MODEL RECORD 68287B/68387B 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 [...]
-
Page 465
682XXB/683XXB MM A-227 3-7 Frequency Synthesis Tests (Continued) Coarse Loop/YIG Loop Test Procedure (Continued) T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 51.000 000 000 52.000 000 000 53.000 000 000 54.000 000 000 55.000 000 000 _____________________ _____________________ _____________________ __________[...]
-
Page 466
A-228 682XXB/683XXB MM TEST MODEL RECORD 68287B/68387B 3-8 Spurious Signals Test: RF Output Signals <2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 10 MHz Record the presence of the worst case harmonic .......... Record the presence of the worst case non-harmonic ....... _______________dBc _______________dBc –30 dBc –40 dBc Set F[...]
-
Page 467
682XXB/683XXB MM A-229 TEST MODEL RECORD 68287B/68387B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz Test Procedure (2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.1 GHz Record the level of all harmonics of the 2.1 GHz carrier: 4.2 GHz (2nd harmonic) ..................... 6.3 GHz (3rd harmonic) ...................... 8.4 GHz (4th harmo[...]
-
Page 468
A-230 682XXB/683XXB MM TEST MODEL RECORD 68287B/68387B 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ..........................[...]
-
Page 469
682XXB/683XXB MM A-231 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 26.5 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. ______________[...]
-
Page 470
A-232 682XXB/683XXB MM TEST MODEL RECORD 68287B/68387B 3-11 Power Level Accuracy and Flatness Tests (Model 68287B/68387B without Option 2D Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 55.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +10 dBm + 9 dBm + [...]
-
Page 471
682XXB/683XXB MM A-233 TEST MODEL RECORD 68287B/68387B 3-11 Power Level Accuracy and Flatness Tests (Continued) (Model 68287B/68387B with Option 2D Step Attenuator) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 55.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * + 8.5 dBm[...]
-
Page 472
A-234 682XXB/683XXB MM TEST MODEL RECORD 68287B/68387B 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calcula[...]
-
Page 473
682XXB/683XXB MM A-235 TEST MODEL RECORD 68287B/68387B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period[...]
-
Page 474
A-236 682XXB/683XXB MM TEST MODEL RECORD 68287B/68387B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Record the displayed output level L1 (step 5.b) .................... Reco[...]
-
Page 475
682XXB/683XXB MM A-237/A-238 TEST MODEL RECORD 68287B/68387B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents [...]
-
Page 476
[...]
-
Page 477
ANRITSU Model 68287B/68387B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-239 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 478
A-240 682XXB/683XXB MM TEST MODEL RECORD 68287B/68387B 4-10 ALC Slope Calibration (68387B having Firmware Version 2.00 and above) Procedure Step Step Completion 5. ALC Slope DAC adjustment ................................ ______________ 6. Store the DAC setting value(s) ............................... ______________ 4-9 RF Level Calibration This ca[...]
-
Page 479
682XXB/683XXB MM A-241 TEST MODEL RECORD 68287B/68387B 4-13 FM Calibration (68287B/68387B with Firmware Version 1.01 to 2.10) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sens[...]
-
Page 480
A-242 682XXB/683XXB MM TEST MODEL RECORD 68287B/68387B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 481
ANRITSU Model 68295B/68395B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-243 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) .[...]
-
Page 482
A-244 682XXB/683XXB MM 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1.000 000 000 12.000 000 000 13.[...]
-
Page 483
682XXB/683XXB MM A-245 3-7 Frequency Synthesis Tests (Continued) Coarse Loop/YIG Loop Test Procedure (Continued) T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 51.000 000 000 52.000 000 000 53.000 000 000 54.000 000 000 55.000 000 000 56.000 000 000 57.000 000 000 58.000 000 000 _____________________ _________[...]
-
Page 484
A-246 682XXB/683XXB MM 3-8 Spurious Signals Test: RF Output Signals 2.2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 500 MHz Record the level of all harmonics of the 500 MHz carrier 1.0 GHz (2nd harmonic) ..................... 1.5 GHz (3rd harmonic) ...................... 2.0 GHz (4th harmonic) ...................... 2.5 GHz (5th ha[...]
-
Page 485
682XXB/683XXB MM A-247 3-9 Harmonic Test: RF Output Signals From 2.2 to 20 GHz Test Procedure (2.2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.4 GHz Record the level of all harmonics of the 2.4 GHz carrier: 4.8 GHz (2nd harmonic) ..................... 7.2 GHz (3rd harmonic) ...................... 9.6 GHz (4th harmonic) ...................... [...]
-
Page 486
A-248 682XXB/683XXB MM TEST MODEL RECORD 68295B/68395B 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ..........................[...]
-
Page 487
682XXB/683XXB MM A-249 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 26.5 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............................. ______________[...]
-
Page 488
A-250 682XXB/683XXB MM 3-11 Power Level Accuracy and Flatness Tests (Model 68295B/68395B) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 60.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 dBm + 3 dBm + 2 dBm + 1 dBm 0 dB[...]
-
Page 489
682XXB/683XXB MM A-251 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calculate and record the actual AM inpu[...]
-
Page 490
A-252 682XXB/683XXB MM 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period) ............................. [...]
-
Page 491
682XXB/683XXB MM A-253 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Record the displayed output level L1 (step 5.b) .................... Record the displayed output level L1[...]
-
Page 492
A-254 682XXB/683XXB MM TEST MODEL RECORD 68295B/68395B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.10 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents an On/[...]
-
Page 493
ANRITSU Model 68295B/68395B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-255 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 494
A-256 682XXB/683XXB MM 4-9 RF Level Calibration This calibration is performed using an automatic test system. Contact ANRITSU Customer Service for further information. 4-10 ALC Slope Calibration (68395B having Firmware Version 1.00 or above) Procedure Step Step Completion 5. ALC Slope DAC adjustment ................................ ______________ 6[...]
-
Page 495
682XXB/683XXB MM A-257 4-13 FM Calibration (68295B/68395B with Firmware Version 1.00) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sensitivity Calibration (calterm 124) ......[...]
-
Page 496
A-258 682XXB/683XXB MM TEST MODEL RECORD 68295B/68395B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 497
ANRITSU Model 68297B/68397B Date: __________________________ Serial Number __________________ Tested By: __________________________ 682XXB/683XXB MM A-259 3-6 Internal Time Base Aging Rate Test Test Procedure Measured V alue Upper Limit Record frequency error value .................... _______________ Record frequency error value (after 24 hours) .[...]
-
Page 498
A-260 682XXB/683XXB MM TEST MODEL RECORD 68297B/68397B 3-7 Frequency Synthesis Tests Coarse Loop/YIG Loop Test Procedure T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured Value * 1.000 000 000 2.000 000 000 3.000 000 000 4.000 000 000 5.000 000 000 6.000 000 000 7.000 000 000 8.000 000 000 9.000 000 000 10.000 000 000 1 1[...]
-
Page 499
682XXB/683XXB MM A-261 3-7 Frequency Synthesis Tests (Continued) Coarse Loop/YIG Loop Test Procedure (Continued) T est Frequency (in GHz) Measured V alue * T est Frequency (in GHz) Measured V alue * 51.000 000 000 52.000 000 000 53.000 000 000 54.000 000 000 55.000 000 000 56.000 000 000 57.000 000 000 58.000 000 000 _____________________ _________[...]
-
Page 500
A-262 682XXB/683XXB MM TEST MODEL RECORD 68297B/68397B 3-8 Spurious Signals Test: RF Output Signals <2 GHz Test Procedure Measured V alue Upper Limit Set F1 to 10 MHz Record the presence of the worst case harmonic .......... Record the presence of the worst case non-harmonic ....... _______________dBc _______________dBc –30 dBc –40 dBc Set F[...]
-
Page 501
682XXB/683XXB MM A-263 TEST MODEL RECORD 68297B/68397B 3-9 Harmonic Test: RF Output Signals From 2 to 20 GHz Test Procedure (2 to 10 GHz) Measure V alue Upper Limit Set F1 to 2.1 GHz Record the level of all harmonics of the 2.1 GHz carrier: 4.2 GHz (2nd harmonic) ..................... 6.3 GHz (3rd harmonic) ...................... 8.4 GHz (4th harmo[...]
-
Page 502
A-264 682XXB/683XXB MM TEST MODEL RECORD 68297B/68397B 3-10 Single Sideband Phase Noise Test Test Procedure Measured V alue Upper Limit Set F1 to 0.6 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz ..........................[...]
-
Page 503
682XXB/683XXB MM A-265 TEST MODEL RECORD 68297B/68397B 3-10 Single Sideband Phase Noise Test (Continued) Test Procedure Measured V alue Upper Limit Set F1 to 26.5 GHz Record the phase noise levels at these offsets: 100 Hz ............................... 1 kHz .............................. 10 kHz .............................. 100 kHz .............[...]
-
Page 504
A-266 682XXB/683XXB MM TEST MODEL RECORD 68297B/68397B 3-11 Power Level Accuracy and Flatness Tests (Model 68297B/68397B) Power Level Accuracy Test Procedure Set F1 to 5.0 GHz Set F1 to 25.0 GHz Set F1 to 60.0 GHz Set L1 to: Measured Power * Set L1 to: Measured Power * Set L1 to: Measured Power * +10 dBm + 9 dBm + 8 dBm + 7 dBm + 6 dBm + 5 dBm + 4 [...]
-
Page 505
682XXB/683XXB MM A-267 TEST MODEL RECORD 68297B/68397B 3-12 Amplitude Modulation Test AM Imput Sensitivity Procedure Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the Modulation Analyzer AM PK(+) reading ........... Measure and record the Modulation Analyzer AM PK(–) reading ........... __________ __________ Calcula[...]
-
Page 506
A-268 682XXB/683XXB MM TEST MODEL RECORD 68297B/68397B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level Rise Time, Fall Time, and Overshoot Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Measure and record the following: Rise T ime .............................. Pulse Width ............................. PRI (period[...]
-
Page 507
682XXB/683XXB MM A-269 TEST MODEL RECORD 68297B/68397B 3-14 Pulse Modulation Tests: Rise Time, Fall Time, Overshoot, and Level (Continued) Pulse Level Accuracy (5 GHz, Pulse Width = 0.5 m s) Lower Limit Measured V alue Upper Limit Set F1 to 5.0 GHz Set pulse width W1 to 5.0 s Record the displayed output level L1 (step 5.b) .................... Reco[...]
-
Page 508
A-270 682XXB/683XXB MM TEST MODEL RECORD 68297B/68397B 3-16 Pulse Modulation Test: RF On/Off Ratio Test Procedure (1 GHz) Lower Limit Measured V alue Upper Limit Set F1 to 1.0 GHz Measure and record the peak of the signal on the Spectrum Analyzer . (Measured signal must be >60 dB below top graticule to meet specification; this represents an On/O[...]
-
Page 509
ANRITSU Model 68297B/68397B Date: __________________________ Serial Number __________________ Calibrated By: __________________________ 682XXB/683XXB MM A-271 4-7 Preliminary Calibration Procedure Step Step Completion 1. Internal DVM Calibration (calterm1 19) ........................... ______________ 2. Coarse Loop Pretune DAC Calibration (calterm[...]
-
Page 510
A-272 682XXB/683XXB MM TEST MODEL RECORD 68297B/68397B 4-10 ALC Slope Calibration (68397B having Firmware Version 2.00 or above) Procedure Step Step Completion 5. ALC Slope DAC adjustment ................................ ______________ 6. Store the DAC setting value(s) ............................... ______________ 4-9 RF Level Calibration This cal[...]
-
Page 511
682XXB/683XXB MM A-273 TEST MODEL RECORD 68297B/68397B 4-13 FM Calibration (68297B/68397B with Firmware Version 1.01 to 2.10) Procedure Step Step Completion 1. FM Meter Calibration (calterm 123) ............................ ______________ 2. FM Of fset Balance Calibration (calterm 126) ....................... ______________ 3. External FM Wide Sens[...]
-
Page 512
A-274 682XXB/683XXB MM TEST MODEL RECORD 68297B/68397B 4-14 Phase Modulation ( F M) Calibration (Option 6) Procedure Step Step Completion 1. External Wide M Mode Sensitivity Calibration (calterm 149) .............. ______________ 2. Internal Wide M Mode Sensitivity Calibration (calterm 151) ............... ______________ 3. Wide M Mode Flatness Cal[...]
-
Page 513
Subject Index 0 - 9 682XXB/683XXB Assembly and Component Locator Diagram, 6-9 General Description, 1-3 Major Subsystems Functional Description, 2-3 Manuals, Related, 1-6 Models, List of, 1-4 - 1-5 Options, List of, 1-7 Startup Configurations, 1-1 1 System Block Diagram, 2-6 - 2-7 A ALC/AM/Pulse Modulation Subsystem Block Diagram, 2-17 Functional De[...]
-
Page 514
N Normal Operation Error/W arning Messages, 5-7 O Options, List of, 1-7 P Parts and Subassemblies, Replaceable, 1-14 Parts Ordering Information, 1-14 ANRITSU Service Centers, 1-14 Performance V erification T ests, 3-3 Preventive Maintenance Fan Filter Cleaning, 1-9 R Rear Panel Assembly Remove/Replace Procedures, 6-13 Recommended T est Equipment, 1[...]