Go to page of
Similar user manuals
-
Portable Generator
Anritsu MG3681A
4 pages 0.32 mb -
Marine Lighting
Anritsu 37xxxE
553 pages 6.79 mb -
Network Router
Anritsu S331D
132 pages 0.7 mb -
Radio Antenna
Anritsu S820A
16 pages 0.56 mb -
Stereo System
Anritsu S331C
95 pages 0.71 mb -
Portable Generator
Anritsu 682XXB
514 pages 4.08 mb -
Electronic Keyboard
Anritsu MG3700A
36 pages 3.78 mb -
Portable Generator
Anritsu 681XXC
241 pages 2.76 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Anritsu MW9076, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Anritsu MW9076 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Anritsu MW9076. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Anritsu MW9076 should contain:
- informations concerning technical data of Anritsu MW9076
- name of the manufacturer and a year of construction of the Anritsu MW9076 item
- rules of operation, control and maintenance of the Anritsu MW9076 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Anritsu MW9076 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Anritsu MW9076, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Anritsu service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Anritsu MW9076.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Anritsu MW9076 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
MW9076 Series Optical Time Domain Reflectometer 1.31/1.45/1.55/1.625 µm (SM), 0.85/1.3 µm (GI) T omorr o ws T echnolog y , T oda y[...]
-
Page 2
2 Highest P er formance, Functions, and Measuring Speed ■ 45 dB high dynamic range ■ 8 m short dead zone ■ Simple measurement of chr omatic dispersion fr om one end of optical fiber ■ Measurement in 10 s (Full-A uto mode), 0.15 s real-time s weep ■ A utomatic execution of functions suc h as wavelength/c hannel switc hing, file sa ving, pr[...]
-
Page 3
3[...]
-
Page 4
4 ● High-Speed Measurement It takes only 10 seconds to measure and displa y the wav e- f or m and connection loss on one screen. Just one press of the Star t key is all that is needed to mak e measurement. ● Short Dead Zone Clearly measure up to near end by 8 m dead zone (back-scatter , SM unit) ● High Dynamic Range When using a wa velength o[...]
-
Page 5
5 ● Fresnel Reflection The f ar-end F resnel reflection can be measured for f our wa velengths (1310/1450/1550/1625 nm). ● Group Delay Characteristics The fitting f or mula suppor ts cubic or quintic Sellmeier , and polynomials can be applied to various types of fibers. ● Chromatic Dispersion Characteristics The zero and total dispersion can [...]
-
Page 6
6 Compact, Lightweight, and Easy to Operate O TDR (main frame) Lithium ion batter y mounted, with remaining power displa y Connector f or e xter nal CRT Displa y unit Measurement conditions can be changed at mea- surement screen Large easy-to-read 8.4 inch TFT -LCD Simultaneous displa y of measured results and e vent tab le Rotar y encoder f or eas[...]
-
Page 7
7 q Status-indicating LED w Function keys e Menu key r Star t key t Arrow ke y y Select key u Batter y pack i Optical power meter connector o Visible LD output connector !0 OTDR connector and light source connector f or optical loss measure- ment !1 Exter nal monitor (V GA) connector !2 PC card slot (two PC cards con- nectable) !33333 Exter nal key[...]
-
Page 8
8 High-Speed Measurement ● Full Automatic Mode Measurement results are displa yed by simply pressing the Star t key . All complicated settings of distance range, pulse width, attenuator , and mar ker can be automatically e xecuted. Measurement speed in this mode was significantly increased. When the wa velengths are set to ALL, w av elengths are [...]
-
Page 9
9 V arious Useful Functions ● Waveform Comparison Function Measured and sav ed data can be compared on the same screen. In addition, differences can be displa yed as a wa vef orm for simple observation of distance and le vel dif- f erences. This is useful f or checking aging changes or comparing sev eral fibers. ● Communication Light Check Func[...]
-
Page 10
10 ● Light Source, Power Meter Optical fiber loss can be measured using the optical powe r meter function and light source function. T w o types of optical power meters are supported: One is measurement range of –70 to +3 dBm (MW9076B/B1/C-02 option), the other is measurement range of –50 to +23 dBm (MW9076B/B1/C-03 option). ● VGA Output T [...]
-
Page 11
11 ● Both-End Measurement Function A new w av eform can be composed by a veraging data mea- sured at both ends of an optical fiber . ● Data T ransmission Function Data files recorded by the MW9076 series can be transf erred to a PC via the RS-232C por t. ● Emulation Function Measured wa vef orm data can be analyzed using a PC. MX907600A O TDR[...]
-
Page 12
● Report Output The ev ent table of a specified file is analyzed and the printed automatically . It is also possible to print multiple wav eforms on one page. In par ticular , at both ends measurement, the measurement results f or both ends can be output automati- cally in a repor t. In addition, the repor t can be sav ed as the Excel file. ● C[...]
-
Page 13
13 Model MW9076B MW9076C MW9076B1 MW9076J MW9076K MW9076D1 W avelength 1310/1550 nm 1310/1550/1625 nm 1310/1550 nm 850 nm 850/1300 nm 1310/1450/1550/ ±25 nm ∗ 1 ±25 nm ∗ 1 ±25 nm ∗ 1 ±30 nm ±30 nm 1625 nm ±3 nm ∗ 1 Measurable optical fiber 10/125 µm single-mode optical fiber (ITU-T G.652) 62.5/125 µm GI fiber ∗ 2 Optical connector[...]
-
Page 14
14 Model MW9076B MW9076C MW9076B1 MW9076J MW9076K MW9076D1 Applicable optical fibers: SM optical fiber (ITU-T G.652) Optical connectors: Shared with O TDR (same por t) Light-emitting elements: FP-LD Center wav elength: 1310/1550 ±25 nm (MW9076B, CW , 25°C) 1310/1550/1625 ±25 nm (MW9076C, CW , 25°C) Spectrum width: ≤ 5/10 nm (MW9076B, CW , 25?[...]
-
Page 15
Model MW9076B MW9076C MW9076B1 MW9076J MW9076K MW9076D1 15 ∗ 1 At 25°C, pulse width: 1 µs ∗ 2 For GI fiber (core diameter: 62.5 µm ±3.0 nm, NA: 0.275 ±0.015, transmission loss: ≤ 3.2/0.9 dB/km (wav elength: 0.85/1.3 µm). At measurement of 50/125 µm GI fiber , the dynamic range drops by about 3.0 dB. ∗ 3 At 25°C, pulse width: SM 20 ?[...]
-
Page 16
16 ● MU250000A/A1/A4 Display Unit MU250000A Unit: 8.4 inch color , TFT -LCD (640 × 480 pixels , transparent type, with bac k light) Display MU250000A1 Unit: 7.2 inch color , STN-LCD (640 × 480 pixels , semi-transparent type, with bac k light on/off) MU250000A4 Unit: 7.8 inch color , STN-LCD (640 x 480 pixels , reflective type , with front light[...]
-
Page 17
Ordering Information 17 Model/order No . Name Remarks Optical Time Domain Reflectometer (main frame) MW9076B SMF 1.31/1.55 µm O TDR Requires Display Unit MW9076B1 SMF 1.31/1.55 µm OTDR Requires Display Unit MW9076C SMF 1.31/1.55/1.625 µm O TDR Requires Display Unit MW9076D1 SMF 1.31/1.45/1.55/1.625 µm O TDR Requires Display Unit MW9076J GIF 0.8[...]
-
Page 18
Model/order No . Name Remarks JT512MA3-NT1 PC-A T A card (512 MB) J0057 Optical adapter FC type T o connect optical fiber cable with FC connector J0635 ∗ 3 Optical fiber cord With FC-PC at both ends (SM) B0442 Soft carrying case For MW9076B/B1/C/J/K, 440 (W) × 310 (H) × 110 (D) mm Z0435 Soft carr ying case For MW9076D1(MW9076B/B1/C + MU960001A/[...]
-
Page 19
Selection Guide 19 Visible LD (Option 01) Display Units Main Frames Options MU250000A 8.4" TFT -LCD F or indoor , exceedingly easy to see MU250000A1 7.2" STN-LCD F or indoor , easy to see MU250000A4 7.8" STN-LCD F or outdoor , exceedingly easy to see under direct sunshine MW9076B1: High cost perf or mance F or SM fiber F or GI fiber [...]
-
Page 20
ANRITSU CORPORA TION 5-10-27, Minamiazabu, Minato-ku, T okyo 106-8570, Japan Phone: +81 - 3 - 3446 - 1111 T elex: J34372 F ax: +81 - 3 - 3442 - 0235 • • U.S.A. ANRITSU COMP ANY North American Region Headquar ters 1155 East Collins Blvd., Richardson, Tx 75081, U.S .A. T oll Free: 1 - 800 - ANRITSU (267 - 4878) Phone: +1 - 972 - 644 - 1777 F ax: [...]