A.O. Smith BFC - 100 manual

1
2
3
4
5
6

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of A.O. Smith BFC - 100, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of A.O. Smith BFC - 100 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of A.O. Smith BFC - 100. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of A.O. Smith BFC - 100 should contain:
- informations concerning technical data of A.O. Smith BFC - 100
- name of the manufacturer and a year of construction of the A.O. Smith BFC - 100 item
- rules of operation, control and maintenance of the A.O. Smith BFC - 100 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of A.O. Smith BFC - 100 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of A.O. Smith BFC - 100, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the A.O. Smith service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of A.O. Smith BFC - 100.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the A.O. Smith BFC - 100 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Innovation has a name. Cyclone BFC Condensing Glass-Lined W ater Heater BFC - 28/30/50/60/80/100 Fu ll y r oo m- se al ed c on de ns in g hi gh -e ffi ci en cy w at er h ea te r (9 5% gr os s) • Flexible fl ue options (maximum length 115 m) allows installation almost anywhere • ThermoControl for easy fl exible control/fault diagnosis • Mee[...]

  • Page 2

    Cyclone BFC T echnical specifications Gas data natural gas 2H (G20) Input* kW 32.1 34.5 52.6 63.2 86.6 105.5 Output kW 30.5 32.7 48.8 59.6 81.9 99.8 Inlet pressure mbar 20 20 20 20 20 20 Burner pressure mbar 8.5 8.5 8.5 11.5 7.0 6.0 Gas consumption** m 3 /h 3.1 3.3 5.0 6.0 8.3 10.1 Diameter main orifice mm 4.90 5.10 7.00 7.10 6.30 6.80 Max. flue[...]

  • Page 3

    BFC 80-100 BFC 28-60 Cyclone BFC Dimensions A 1390 1910 1910 1910 2060 2060 C - - - - 530 530 D 705 705 705 705 850 850 E - - - - 1000 1000 F - - - - 900 900 G 80/125 100/150 100/150 100/150 130/200 130/200 H 1365 1905 1905 1905 2015 2015 Hx 265 265 265 265 310 310 Hy 375 375 375 375 440 440 K 1270 1800 1800 1800 1855 1855 M 170 160 160 160 225 225[...]

  • Page 4

    V ented Unvented 1 Pressure reducing valve 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump 9 Drain valve 10 Gas cock 11 Isolating valve 12 T emperature gauge 13 Condense drain 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel 17 Three way valve 18 Water tank 19 Float valve A Cold water B Hot water C Return circul[...]

  • Page 5

    Cyclone BFC Electrical diagram BFC 28-60 Cyclone BFC Electrical diagram BFC 80-100 TERMINAL STRIP CONNECTIONS Earth N Neutral L Phase input of controller L1 Phase output of isolating transformer ( secundary side) L2 Phase input of isolating transformer ( primary side) L3 Phase input of program- controlled pump L4 Phase input of frequency controller[...]

  • Page 6

    www .aosmithinternational.com Data subject to change INT/1108/BFC/04 T erms and conditions apply , please refer to our website Flue systems Cyclone BFC Installation options B23 C13 C33 C53 C43 A C yclon e BFC wate r hea ter s hould be i nstal led a ccord ing category B23, C13, C33, C43 or C53*. Concentric Diameter (mm) 80/125 100/150 100/150 100/15[...]