Go to page of
Similar user manuals
-
Water Heater
A.O. Smith AOSRG46600
2 pages 1.01 mb -
Water Heater
A.O. Smith BTR(C) 120 Thru 400A Standard
8 pages 0.59 mb -
Water Heater
A.O. Smith BTP-740A
2 pages 0.08 mb -
Water Heater
A.O. Smith 750 SERIES
24 pages 0.32 mb -
Water Heater
A.O. Smith BT180-100
1 pages 2.25 mb -
Water Heater
A.O. Smith GDV-75
31 pages 1.19 mb -
Water Heater
A.O. Smith ADM - 50
74 pages 3.01 mb -
Water Heater
A.O. Smith HYB-90N
60 pages 1.92 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of A.O. Smith BTP(V)-540A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of A.O. Smith BTP(V)-540A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of A.O. Smith BTP(V)-540A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of A.O. Smith BTP(V)-540A should contain:
- informations concerning technical data of A.O. Smith BTP(V)-540A
- name of the manufacturer and a year of construction of the A.O. Smith BTP(V)-540A item
- rules of operation, control and maintenance of the A.O. Smith BTP(V)-540A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of A.O. Smith BTP(V)-540A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of A.O. Smith BTP(V)-540A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the A.O. Smith service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of A.O. Smith BTP(V)-540A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the A.O. Smith BTP(V)-540A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 MODELS BTP(V)-540A, 650A AND 740A COMMERCIAL GAS, GLASS-LINED, TANK-TYPE LOW NOx WA TER HEA TER CONSER CONSER CONSER CONSER CONSER V V V V V A A A A A TIONIST TIONIST TIONIST TIONIST TIONIST ® ® ® ® ® P ART NO. 195033-000 CAUTION TEXT PRINTED OR OUTLINED IN RED CONT AINS IN- FORMA TION RELA TIVE TO YOUR SAFETY . PLEASE READ THOROUGHL Y BEFOR[...]
-
Page 2
2 FOREWORD The design of the BTP 540A through 740A models complies with ANSI Z21.10.3/CSA 4.3 as an automatic circulating tank and an automatic instantaneous type heater . The BTPV 540A through 740A models are designed for sidewall venting and direct venting applications and are certified under UL 795. Detailed installation diagrams are found in th[...]
-
Page 3
3 are different from natural gas models. A natural gas heater will not function safely on LP gas and no attempt should be made to convert a heater from natural gas to LP gas. BTP(V)-540A, 650A & 740A models are not available for use with Liquefied Petroleum or LP gas. If you have obtained a BTP(V)-540A, 650A or 740A model with the intent to use[...]
-
Page 4
4 and sodium chloride (water softener salt), waxes, and process chemicals are typical compounds which are potentially corrosive. Do not store products of this sort near the heater . Also, air which is brought in contact with the heater should no contain any of these chemicals. If necessary , uncontaminated air should be obtained from remote or outs[...]
-
Page 5
5 Continued manual resetting of high limit control, preceded by higher than usual water temperature is evidence of high limit switch operation. The following are possible reasons for high limit switch operation. • A malfunction in the thermostatic controls would allow the gas valve to remain open causing water temperature to exceed the thermostat[...]
-
Page 6
6 Units, which are to be installed on combustible flooring, must be supported by a full layer of hollow concrete blocks, from 8” (203.2 mm) to 12” (304.8 mm) thick and extending 12” (304.8 mm) minimum beyond the heater in all directions. The concrete blocks must provide an unbroken concrete surface under the heater with the hollows running co[...]
-
Page 7
7 Heater must be protected from freezing downdrafts during shutdown periods. The BTP 540A, 650A and 750A water heater are classified as a category I appliance (non-positive vent pressure, non- condensing) when installed with the supplied barometric draft control assembly in a vertical vent installation. The BTPV 540A through 740A heater is classifi[...]
-
Page 8
8 Refer to T able 2 for limitations of venting system design for horizontal venting. T ABLE 2 BTPV-540A-740A Flue Outlet Dia. (Inches/mm) 9” (228.6) Flue Reducer 9” x 8” Dimensions -Supplied (Inches/mm) 228.6 x 203.2 Minimum Outlet V ent Dia. (Inches/mm) 8” (203.2) Maximum Number 90° 4 Of Elbows 45° 8 Maximum T otal V ent System 75 Length[...]
-
Page 9
9 DIRECT VENTING - FOR BTPV MODELS All exhaust vent terminal, flue reducer , and intake vent terminal are supplied with any unit intended for direct venting. These parts must be installed without alteration. This heater is category III appliance when used in a direct vent application. All national and local codes pertaining to the installation of s[...]
-
Page 10
10 1. Shall be located not less than 12” (304.8 mm) above grade. 2. Shall be located not less than 3 (.9144 m) feet horizontally from and not less than 3 feet (.9144 m) below an exhaust vent terminal. 3. Shall not be located directly above an exhaust terminal. 4 . Shall be located 12” (304.8 mm) above the snow line in geographical areas where s[...]
-
Page 11
11 5. Attach a properly sized length of Selkirk Metalbestos model PS or model G venting to the exhaust vent adapter using the inner vee bands, see Figures 7 and 7B on page 10. 6. Fill the grooves in both inner vee bands with high-temp silicone sealant, Dow Corning 736 or equivalent. 7. Position the inner vee bands around the inner pipe flanges and [...]
-
Page 12
12 T ABLE 9A MAXIMUM CAP ACITY OF PIPE IN CUBIC FEET OF GAS PER HOUR (Based upon a Pressure Drop of 0.5 inch Water Column and 0.5 Specific Gravity Gas and max. gas press. of .5 psig) LENGTH I N Nominal Iron Pipe Sizes, Millimeters METERS 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3 " 4 " 3.0 51 105 199 410 615[...]
-
Page 13
13 ROBERTSHA W ® 7000 DERHC GAS CONTROL V AL VE FIGURE 10. W A TER LINE CONNECTIONS Following are detailed installation diagrams for typical methods of application for the water heaters. The water heater may be installed by itself, or with a separate storage tank, on both single and two-temperature systems. When used with a separate storage tank, [...]
-
Page 14
14 INST ALLA TION DIAGRAMS ONE TEMPERA TURE - ONE HEA TER VERTICAL STORAGE T ANK FORCED CIRCULA TION WITH OR WITHOUT BUILDING RECIRCULA TION DANGER IF BUILDING COLD W A TER SUPPL Y HAS A BACKFLOW PREVENTER, CHECK V A L VE OR W A TER METER WITH CHECK VAL VE, PROVISIONS FOR THERMAL EXP ANSION OF W A TER IN THE HOT WA TER SYSTEM MUST BE PROVIDED. NOTE[...]
-
Page 15
15 TWO TEMPERA TURE - ONE HEA TER HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION TWO TEMPERA TURE - TWO HEA TERS HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION *PIPE RELIEF V AL VE TO OPEN DRAIN NOTE: IF TEMPERED W A TER IS RECIRCULA TED, RETURN LINE SHOULD BE CONNECTED A T POINT “A”. INSTALL IN ACCORDANCE WITH LOCAL CODES[...]
-
Page 16
16 CAUTION: IF BUILDING COLD W A TER SUPPL Y HAS A BACKFLOW PREVENTER, CHECK V ALVE OR W A TER METER WITH CHECK V AL VE, PROVISIONS FOR THERMAL EXP ANSION OF WA TER IN THE HOT WA TER SYSTEM MUST BE PROVIDED. TWO TEMPERA TURE - THREE HEA TERS (TWO PRE-HEA TERS/ONE BOOSTER) WITH OR WITHOUT BUILDING RECIRCULA TION TWO TEMPERA TURE - TWO HEA TERS (ONE [...]
-
Page 17
17 TWO TEMPERA TURE - ONE HEA TER HIGH TEMPERA TURE WITH RECIRCULA TION OF SANITIZING LOOP CAUTION: IF BUILDING COLD WA TER SUPPL Y HAS A BACKFLOW PREVENTER, CHECK V AL VE OR W A TER METER WITH CHECK V AL VE, PROVISIONS FOR THERMAL EXP ANSION OF W A TER IN THE HOT WA TER SYSTEM MUST BE PROVIDED. DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE TE[...]
-
Page 18
18 MANIFOLD KITS Precision cut type “L” all copper A. O. Smith manifold kits assure water flow balance of all units. Without this balance, the full water heating and storage potential of the system cannot be achieved. Plus, the units with the higher water flow may have a shortened life. Unions shown in piping diagrams are not included in the ma[...]
-
Page 19
19 HEA TER WIRING IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH 105°C WIRE OR ITS EQUIV ALENT , EXCEPT IN THE BURNER HOUSING USE 200°C WIRE. The power burner is wired to the heater as shown in Figure 1 1 for BTP models and Figure 12 for BTPV models. The model and rating plate provided the el[...]
-
Page 20
20 FIGURE 1 1.[...]
-
Page 21
21 FIGURE 12.[...]
-
Page 22
22 FOR YOUR SAFETY READ BEFORE LIGHTING 1. Remove thermostat control cover . 2 . Set thermostat to lowest setting. 3 . Turn burner switch to “OFF”. W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition de[...]
-
Page 23
23 SEQUENCE OF OPERA TION – Power on. – Heater in standby mode. – Thermostat calls for heat. – Blower motor starts. – Blower operation closes the normally open blower prover/ blocked outlet safety pressure switch. – On proof of airflow , Honeywell S8680J flame control module energized. – 45 seconds prepurge cycle begins. – Following[...]
-
Page 24
24 1. Check gas line pressure with a manometer . Set initial gas line pressure at 9-10” w .c. before turning the heater “ON”. Read gas line pressure and gas manifold pressure when the heater main gas is “ON”. Adjust gas line regulator setting if the gas line pressure drops below 8” w .c. when heater main gas is “ON”. Check heater ga[...]
-
Page 25
25 PREMIX LOW NOx BURNER - EXPLODED VIEW FOR BTP MODELS FIGURE 13.[...]
-
Page 26
26 PREMIX LOW NOx BURNER - EXPLODED VIEW FOR BTPV MODELS FIGURE 14.[...]
-
Page 27
27 GENERAL INFORMA TION POWER BURNER The initial start-up procedure of the gas power burner is provided on page 18 thru 21. Refer to Figure 12, burner exploded view for burner components location. The sequence of operation of the power burner is provided on page 15. For detailed Power Burner Operation, Maintenance and Troubleshooting refer to the s[...]
-
Page 28
28 DRAINING The heater must be drained if it is to be shut down and exposed to freezing temperatures. Maintenance and service procedures may also require draining the heater . 1. Turn off the heater electrical disconnect switch. 2. Close the cold water inlet valve to heater . 3. Open a nearby hot water faucet to vent the system. 4. Open the heater [...]
-
Page 29
29 ABOVE ALL, DO NOT PLUG THE TEMPERA TURE AND PRESSURE RELIEF V AL VE. THIS IS NOT A SOLUTION AND CAN CREA TE A HAZARDOUS SITUA TION. CIRCULA TING PUMP The water heating system may include a circulating pump. Where used, it should be lubricated as directed by the circulator manufacturer . LOW EMISSION POWER BURNER KEEP THE AREA AROUND THE BURNER C[...]
-
Page 30
30 2. Check the fuses. • The electrical disconnect switch usually contains fuses. 3. The capacity of the heater may have been exceeded by a large demand for hot water . 4. Colder incoming water temperature will lengthen the time required to heat water to the desired temperature. • If the heater was installed when incoming water temperature was [...]
-
Page 31
31 Refer to the SEQUENCE OF OPERA TION and burner exploded view , see Figure 12 and the wiring diagram located on page 20, and the troubleshooting section of burner manual before continuing. Make sure the appliance is connected to a 120 V ac power supply , burner switch is “ON” and manual gas valve is in the “ON” position, and all electrica[...]
-
Page 32
32 • Do not proceed to Step 5 unless 24V is detected at “24V” terminal of the Honeywell Module. 5. As soon as the pilot gas valve is energized, check for the burner pilot flame through the burner peek-hole. If the pilot flame is established inside the burner , then proceed to Step 6. • Turn the burner switch to “OFF” position for at lea[...]
-
Page 33
33 Model BTP(V) Limited Warranty A.O. Smith Corporation, the warrantor , extends the following LIMITED W ARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to the natural corrosion from potable water therein, during the first THREE ye[...]
-
Page 34
34 NOTES[...]
-
Page 35
35 NOTES[...]
-
Page 36
36 REPLACEMENT P ARTS 5621 W . 1 15TH STREET , ALSIP , IL 60803 Phone: 800-433-2545 Fax: 800-433-2515 w w w .aosmithwaterheaters.com E-Mail: parts@hotwater .com[...]