Go to page of
Similar user manuals
-
Power Supply
APC 650
66 pages 0.96 mb -
Power Supply
APC G5BLK
42 pages 0.6 mb -
Power Supply
APC 250/450 VA
1 pages 4.36 mb -
Power Supply
APC 1500 VA
19 pages 1.78 mb -
Power Supply
APC SMX2001RMLV2UNC
8 pages 0.21 mb -
Power Supply
APC 1400XLT
40 pages 1 mb -
Power Supply
APC 15000 RAID
152 pages 2.98 mb -
Power Supply
APC SMX 1500 VA
21 pages 0.32 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of APC 600, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC 600 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of APC 600. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of APC 600 should contain:
- informations concerning technical data of APC 600
- name of the manufacturer and a year of construction of the APC 600 item
- rules of operation, control and maintenance of the APC 600 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC 600 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC 600, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC 600.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the APC 600 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Smart-UPS ® Model 600 User’ s Manual Te st[...]
-
Page 2
Important safety instructions! Please r ead this manual! V euillez lir e ce manuel! Bitte lesen Sie dieses Anleitungshandbuch! ¡Se ruega leer este manual de instrucciones! This manual pr ovides safety , installation, and operating instructions that will help you get the fullest performance and service life that the UPS has to of fer . Please save [...]
-
Page 3
1 T able of Contents 1.0 Intr oduction .................................................................... 3 1.1 Overview .......................................................................................................... 3 1.2 SmartBoost .......................................................................................................[...]
-
Page 4
2 8.0 Storing the UPS ............................................................. 35 8.1 Storage conditions ........................................................................................ 35 8.2 Extended storage .......................................................................................... 35 9.0 Specifications ..............[...]
-
Page 5
3 1.0 Intr oduction 1.1 Overview This equipment is a high-performance, line-interactive, uninterr uptible power source (UPS) designed to provide clean, r eliable, AC power to computer loads. The UPS’s line-interactive cir cuit topology (see figure below) of fers excellent efficiency , on-line voltage regulation, and fast utility fault response. T[...]
-
Page 6
4 1.2 SmartBoost SmartBoost allows continuous, on-line operation during extended br own- outs or low line voltage conditions. The UPS compensates for r educed line voltage by boosting the load voltage to 12% above the input. This enhances UPS r eliability because the battery is saved for complete utility failure . 1.3 Batter y replacement indicator[...]
-
Page 7
5 2.0 Safety! ENGLISH Caution! CAUTION! ■ T o r educe the risk of electric shock, disconnect the Uninterruptible Power Source fr om the mains before installing computer interface signal cable (when used). Reconnect the power cor d only after all signalling interconnections have been made. ■ Connect the Uninterruptible Power Source to a two-pole[...]
-
Page 8
6 2.0 Sécurité! FRANÇAIS Attention! A TTENTION! ■ Pour réduire le risque d’électrocution, débranchez la prise principale de la sour ce d’alimentation permanente (Uninterr uptible Power Sour ce), avant d’installer le câble d’interface allant à l’or dinateur (si utilisé). Ne r ebranchez le bloc d’alimentation qu’après avoir [...]
-
Page 9
7 2.0 Sicherheit! DEUTSCH V orsicht! VORSICHT! ■ Um die Gefahr eines elektrischen Schlages auf ein Minimum zu r eduzieren, die unterbr echungsfr eie Stromversorgung vom Stromnetz tr ennen, bevor ggf. ein Computer -Schnittstellensignalkabel angeschlossen wir d. Das Netzkabel erst nach Herstellung aller Signalverbindungen wieder einstecken. ■ Die[...]
-
Page 10
8 2.0 ¡Seguridad! ESP AÑOL ¡Atencion! ¡A TENCION! ■ Para reducir el riesgo de descarga eléctrica, desconecte de la r ed la Fuente de ener gía ininterrumpible antes de instalar el cable de señalización de interfaz de la computadora (si se usa). V uelva a conectar el conductor flexible de alimentación solamente una vez efectuadas todas las[...]
-
Page 11
9 3.0 Pr esentation 3.1 600V A UPS—100 and 120 V ac versions Rear view NEMA 5-15R r eceptacles Computer Interface port See Sec. 6.4 UPS enable switch see Sec. 4.3 Site wir e fault light see Sec. 4.5 Option switches see Sec. 5.5 IEC 320 inlet Cir cuit breaker Display featur es see Section 5.1 T est button see Sec. 5.1.8 Alarm disable button See Se[...]
-
Page 12
10 3.0 Pr esentation 3.2 600V A UPS—220/230/240 V ac version Rear view IEC 320 output couplers Compute Interface port See Sec. 6.4 IEC 320 inlet Cir cuit breaker Front view Display features see Section 5.1 T est button see Sec. 5.1.8 Alarm disable button See Sec. 5.1.9 Power on button see Sec. 5.1.6 Power standby button see Sec. 5.1.7 UPS Enable [...]
-
Page 13
11 4.0 Installation 4.1 Receiving inspection Once you r emove the UPS fr om its shipping container , inspect it for dam- age that may have occurred while in transit. Immediately notify the carrier and place of pur chase if any damage is found. The packing materials are made fr om recyclable materials and should be saved for reuse or disposed of pro[...]
-
Page 14
12 4.3 Connect UPS to service and enable 4.3.1 Connect UPS to service ■ 100, 120 V ac versions Plug the UPS into a two-pole, thr ee-wire gr ounding receptacle only . A void the use of extension cor ds and adapter plugs. ■ 220/230/240 V ac version The 220/230/240 V ac version UPS is not furnished with an input line cor d. Instead, two output cor[...]
-
Page 15
13 4.3.2 Enable UPS Move the UPS Enable switch to the on ( I ) position. When shipped, this switch is in the of f position to pr event accidental activation of the UPS. The batteries will not appr eciably discharge if this switch is left on. Allow the UPS to char ge its battery for at least 8 hours before use. The UPS r echarges its battery wheneve[...]
-
Page 16
14 4.0 Installation 4.6 Switch on load equipment If you leave the load equipment switched on, you can use the UPS’s power on button as a master system on/of f switch. 4.7 Switch on the UPS The UPS and your loads become ener gized when you pr ess and hold the power on button for a second. At power-up, the UPS initiates a battery self-test. During [...]
-
Page 17
15 5.0 Operation 5.1 Display featur es 5.1.1 On Line indicator The On Line indicator lights when the load is being supplied conditioned power fr om the utility service. This indicator blinks during the self-test. 5.1.2 On Battery indicator The On Battery indicator lights when the load has been transferr ed to UPS battery power , and the utility vol[...]
-
Page 18
16 5.1.6 Power on button The power on button turns on the UPS and ener gizes the load. Note that the UPS must be enabled (see Sec. 4.3.2). The UPS’s battery char ger is always active as long as the UPS is plugged in. 5.1.7 Power standby button The power standby button turns of f the UPS and deenergizes the load. The UPS’s battery char ger remai[...]
-
Page 19
17 5.2 Output Power bar graph When you pr ess and hold the T est button, the LED indicators display a bar graph of the power being drawn by the load connected to the UPS. 5.0 Operation This example shows that the equipment plugged into the UPS is drawing between 264 and 330 W atts (400–500 V A for typical computer equipment). If all five indicato[...]
-
Page 20
18 5.4 Audible alarms The UPS featur es an audible alarm that beeps to indicate certain conditions (see Secs. 5.4.1–5.4.4). 5.4.1 On-battery alarm The UPS emits four short beeps every 30 seconds when the UPS is operat- ing on battery power . Y ou may silence this alarm by pr essing the alarm disable button (see Sec. 5.1.9). The on-battery alarm i[...]
-
Page 21
19 5.0 Operation 5.5 Option switches The UPS has a set of four DIP switches on the rear panel which allow you to configur e several options (see Secs. 5.5.1–5.5.4). 0 ( o f f ) I ( o n ) 1 2 3 4 Note: Y ou can set option switches at any time, and the effect is immediate. Note: If all of the option switches are set to the on position, the option s[...]
-
Page 22
20 5.5.2 Option Switch 2 Option Switch 2 functions dif ferently for differ ent versions of the UPS. ■ 100 V ac version No function; not used. ■ 120 V ac version The UPS’s factory-set input voltage limits for on-line and SmartBoost operation ar e centered on the nominal input voltage of 120 V ac (see also Sec. 9.1). When Option Switch 2 is set[...]
-
Page 23
21 5.6 Extended capabilities Sections 5.6.1 thr ough 5.6.4 briefly describe the UPS’s extended capabili- ties—advanced functions accessed using a computer r unning optional PowerDoctor or PowerChute plus UPS monitoring software. Refer to the monitoring softwar e documentation for more information on these func- tions. Note: The extended capabil[...]
-
Page 24
22 ■ Output power The UPS continuously monitors the power consumed by the load. The value given is a per centage of the full load rating of the UPS. This informa- tion may be logged using UPS monitoring softwar e, plotted using a spread- sheet application, and used to track load usage over extended periods. ■ Output voltage, internal temperatur[...]
-
Page 25
23 5.6.4 Operation customizing Y ou may configure many UPS operations for specific applications. T o use the customizing featur es of the UPS, you must set all option switches to the on ( I ) position. The functions or dinarily controlled by the switches ar e duplicated in the UPS monitoring softwar e. Once any of the option switches ar e returned [...]
-
Page 26
24 ■ Audible alarm operation The UPS’s audible alarm beeps four times every 30 seconds during on- battery operation. The alarm beeps continuously when low-battery condi- tions ar e reached. This is the default operation. Y ou may configure the audible alarm operation such that r esponse to utility failure is delayed by 30 seconds, silenced unti[...]
-
Page 27
25 6.0 UPS Monitoring 6.1 Overview A UPS system alone pr ovides excellent protection fr om brief power pro b- lems. During an extended power outage, an unattended computer system will eventually shut down because of battery capacity exhaustion. T o pr event data corruption when the UPS shuts down, the UPS must inform the computer of impending shut [...]
-
Page 28
26 6.4 Computer interface port The computer interface port is diagramed below . Those with technical abilities wishing to use this port in a special application should be awar e of the following limitations and capabilities of the interface. ■ Outputs at Pins 3, 5, and 6 are open-collector outputs which must be pulled up to a common r efer enced [...]
-
Page 29
27 7.0 Difficulty ENGLISH Caution! CAUTION! ■ This Uninterr uptible Power Sour ce contains potentially hazardous voltages. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Repairs are performed only by factory trained service personnel. ■ This Uninterruptible Power Source uses batteries. The batteries will ev[...]
-
Page 30
28 7.0 Difficulté FRANÇAIS Attention! A TTENTION! ■ Cette source d’alimentation permanente (UPS) contient des cir cuits haute tension présentant un danger . Ne jamais essayer de le démonter . Il n’y a aucun composant qui puisse êtr e réparé par l’utilisateur . T outes les réparations doivent êtr e ef fectuées par du personnel qual[...]
-
Page 31
29 7.0 Schwierigkeit DEUTSCH V orsicht! VORSICHT! ■ Im Inneren dieser unterbrechungsfr eien Stromversor gung herrschen potentiell gefährliche Spannungen. Nicht versuchen, das Gerät zu öffnen. Es enthält keine vom Benutzer r eparierbaren T eile. Reparaturen dürfen nur von ausgebildetem Kundendienstpersonal dur chgeführt werden. ■ Diese unt[...]
-
Page 32
30 7.0 Dificultad ESP AÑOL ¡Atencion! ¡A TENCION! ■ Esta Fuente de energía ininterrumpible contiene niveles de voltaje peligr osos en potencia. No intente desarmar la unidad, pues no contiene piezas que puedan ser r eparadas por el usuario. Las reparaciones deben efectuarse únicamente por parte del personal de mantenimiento capacitado en la [...]
-
Page 33
31 7.0 Difficulty 7.1 T r oubleshooting PROBLEM: UPS will not turn on Possible cause: UPS Enable switch is in the off position or the power on switch is not pressed. Solution: T urn on the r ear panel UPS Enable switch. Press fr ont- panel power on switch to energize UPS and loads. Possible cause: UPS’s circuit breaker is tripped (button is exten[...]
-
Page 34
32 7.1 T 7.1 T 7.1 T 7.1 T 7.1 T r r r r r oubleshooting oubleshooting oubleshooting oubleshooting oubleshooting (continued) PROBLEM: UPS does not provide expected back up time. Possible cause: UPS’s battery is weak from recent outage or wear . Solution: The battery needs recharging after an extended outage. The battery wears faster when put into[...]
-
Page 35
33 7.0 Difficulty 7.2 Batter y replacement check The UPS automatically performs a battery test at startup and again every 14 days. This test briefly loads the batteries and can detect a weak battery befor e it is put into service during a power failure. If the battery is too weak to support the load during this test, the UPS instantly r eturns to o[...]
-
Page 36
34 7.0 Difficulty 7.3 Obtaining service The tr oubleshooting chart in Section 7.1 covers most of the dif ficulties that you may encounter under conditions other than a failur e of the UPS itself. For pr oblems not cover ed in the chart, follow the procedur e outlined below . If your UPS r equires service: 1. Refer to the troubleshooting chart (Sec [...]
-
Page 37
35 8.0 Storing the UPS 8.1 Storage conditions When you stor e the UPS, cover it and keep it upright in a cool, dry loca- tion. Store the UPS with its battery fully-char ged. Before storage, allow the UPS to char ge for at least 8 hours. Disconnect any accessories and cables connected at the computer interface port, because these may unnecessarily d[...]
-
Page 38
36 9.0 Specifications 9.1 Input UPS version (V ac): 100 120 220/230/240 Nominal input voltage (V ac): single phase 100 120 230 Nominal input frequency: 50 or 60 Hz. Internally selected by micr opr ocessor . Input protection: 8 Amp 7 Amp 5 Amp Push-to-r eset circuit br eaker . Input connections: IEC 320 male inlet coupler . 120 and 100 V ac versions[...]
-
Page 39
37 9.4 Battery and char ger UPS version (V ac): 100 120 220/230/240 Battery type: Spill proof, maintenance fr ee sealed lead-calcium. T ypical battery life: 3 to 6 years. Battery life dependent on number of dischar ges and ambient temperatur e. Low battery signaling: Continuous visual and audible alarm 2 minutes before shutdown. Recharge time: 4 to[...]
-
Page 40
38 9.7 Physical Size (H ´ W ´ D): 6.6 ´ 4.7 ´ 13.8 in. (17 ´ 12 ´ 35 cm) W eight: 28 lbs (12.7 kg) Shipping weight: 30 lbs (13.6 kg) 9.8 Appr ovals Safety approvals: UL per 1778, CSA per C22.2, TUV per IEC 950. EMC verification: FCC/DOC Class B certified; VCCI Class 2 compli- ance; VDE/EN55022 Class B verified. 9.0 Specifications[...]
-
Page 41
39 9.9 T ypical r un times versus load Load Run T im e T ypical computer (VA † ) (minutes ‡ ) equivalents 250 26 Apple Macintosh IIci w/color monitor Compaq Presario 400/600 Series w/monitor 300 20 Gateway 486/33 tower w/VGA monitor Apple Macintosh IIci w/19-in. color monitor 350 17 NEC PowerMate 386 w/VGA monitor Gateway PS-60 Pentium w/monito[...]
-
Page 42
40 Notes[...]
-
Page 43
Limited W a rranty American Power Conversion (APC) warrants its products to be fr ee from defects in materials and workmanship for a period of two years fr om the date of purchase. Its obligation under this warranty is limited to r epairing or r eplacing, at its own sole option, any such defective products. T o obtain service under warranty you mus[...]
-
Page 44
( PHONE (800) 800-4272 in USA & Canada (401) 789-5735 worldwide * MAILING American Power Conversion 132 Fairgr ounds Road P .O. Box 278 West Kingston, Rhode Island 02892 USA ( PHONE (+33) 1.64.62.59.00 in Eur ope (401) 789-5735 worldwide * MAILING American Power Conversion 4, r ue Ste Clair e Deville Zac du Mandinet-Bâtiment Espace Lognes 7744[...]