Go to page of
Similar user manuals
-
Air Conditioner
APC ACPSC2000
32 pages 1.29 mb -
Air Conditioner
APC ACPSC3500
32 pages 1.29 mb -
Air Conditioner
APC AP7003
28 pages 0.69 mb -
Air Conditioner
APC ACPCW40-150
92 pages 0.9 mb -
Air Conditioner
APC AP7004
28 pages 0.69 mb -
Air Conditioner
APC ACPA4000
52 pages 1.11 mb -
Air Conditioner
APC ACPDX21-86
92 pages 0.9 mb -
Air Conditioner
APC ACPSC3000
32 pages 1.29 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of APC AP7004, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC AP7004 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of APC AP7004. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of APC AP7004 should contain:
- informations concerning technical data of APC AP7004
- name of the manufacturer and a year of construction of the APC AP7004 item
- rules of operation, control and maintenance of the APC AP7004 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC AP7004 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC AP7004, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC AP7004.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the APC AP7004 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
® NetworkAIR™ 1000 Portable Air Conditioner AP7003 AP7004 User’ s Manual[...]
-
Page 2
Important Safety Information Wa r n i n g • Read these instructions carefully befo re using this air conditioner . • This air conditioner is designed f or indoor use only . The temp erature range f or the cooling mode is 6 1° F to 86° F . • T o reduce the risk of fire or electr ic shock, do not expose the unit to rain or m oisture. Do not o[...]
-
Page 3
i Contents General Information . . . . . . . . . . . . . . . . . . . . . . . . 1 About NetworkAIR 1000 1 Inventory 1 Front View 2 Back View 2 Contro l Panel 3 LCD Indicators 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Warnings 5 Set up the unit 5 Check components 6 Power the unit 6 Operation . . . . . . . . . . . [...]
-
Page 4
ii Contents continued Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . 17 Try this first 17 If problems persist 19 Warranty Information . . . . . . . . . . . . . . . . . . . . . 20 Limited warranty 20 Warranty limitations 20 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21[...]
-
Page 5
1 General Information About NetworkAIR 1000 APC ’ s Netwo rkAIR 1000 is a portable, com pact, air- conditioner designed for spot-cooling, em ergency-cooling, and after-hours cooling of server closets, data centers, confer ence rooms, hom e offices, or room s housing heat-sensitive equipment. The NetworkAIR 1000 pro vides 7,200 BTU (7,500 BTU for [...]
-
Page 6
2 General Information continued Fr ont View Back View C ontr o l P ane l Hor izont al Air Fl ow Guides V ertical S w ing Lou ver Handle Wat e r Tan k Caster P ower C or d & Plu g W as h a bl e Ai r Fil te r D ra i n V a l ve Exha ust V ent[...]
-
Page 7
3 General Information continued Contr ol Panel Power T urns the unit on and off. Mode Sets the desire d operating mode: fan, cooling, o r dehumidifying. Fan Speed Sets desired fan speed: high, medium or low . Louver Directs the air distribution. T emperature Sets the desire d temperature (61°– 86°F). Timer Programs the timer for unattended shut[...]
-
Page 8
4 General Information continued LCD Indicators T emperature Fan Mode Cooling Mode Dehumidify Mode Louver On Ti m e r O n / O ff T imer Setting Fan Speed Set T emperature Note: T emp erature i s show n in Celsius on the AP7004.[...]
-
Page 9
5 Installation Wa r n i n g s Use the uni t on a flat surface where the air outlets are unobstructed. Do not place the unit less that 20 inches (50 cm ) away from any wall or obstacle. Do not install this air condition er where there are fum es or flamm able gases, or in an extrem ely humid space such as a green house. Set up the unit 1. Unpack the[...]
-
Page 10
6 Installation continued Check components 1. Check that the condensate tank on the side of the unit is in place and is properly seated. If the tank is not installed properly , the unit wil l not operate. 2. Open the air filter cover on the left sid e of the unit and check that the air filter is clean. Power the unit 1. Plug the unit in to a wall ou[...]
-
Page 11
7 Operation Power T urn the unit on or off by pressing the Power button. Cooling • T o select the Cooling m ode, press the Mode button until the cooling m ode indicator appears in the LCD window . • Set the fan speed by p ressing the Fan Speed button. The fan speed indicator in the LCD window wil l display what speed has been selected - high, m[...]
-
Page 12
8 Operation continued Ti me r Y our portable air con ditioner has a tim er feature that allow s the unit to shut off or turn on automat ically in a preset number of hours. 1. Set Timer On mode a. Make sure mode (cool, dehum idify or fan), tempera- ture, and fan opt ions are on t he desired setting. b. T urn the unit off. c. Press the Timer button a[...]
-
Page 13
9 Installing the Exhaust Kit Installing into ceiling plenum For this installation you wil l need the following: • The ceiling adapter • The holder flange • The exhaust duct • The base flange Note: There should be about 12 to 15 inches of open space above the ceiling adapter opening so that exh aust air is not blocked 1. The exhaust duct is [...]
-
Page 14
10 Installing the Exhaust Kit continued Installing into ceiling plenum, continued 5. For permanen t installation, cut five inches off the ceiling tile so that the tile will l ay flat in the grid. 6. For temporar y installations, slide the ceiling ti le tight against the ceiling adapter . 7. Screw the other en d of the exhau st duct into the base fl[...]
-
Page 15
11 Drainage Methods of Draining The NetworkAIR 1000 has two m ethods of disposi ng of the condensation. The first is a condensate tank that can be manually em ptied. Th e second method is to attach a drain h ose to the unit so the water will run to a floor drain. Condensate Ta n k The condensation will drain in to the condensate tank when the unit [...]
-
Page 16
12 Drainage continued Emptying the tank T o manuall y drain the tank: 1. T urn off the unit . 2. Using the handle, slowly rem ove the tank from the side of the unit. 3. Pour out any condensation accum ulated in the tank. 4. W i pe up any condensation that m ay have drained off the evaporator coil. 5. Replace the tank in the unit. 6. T urn the power[...]
-
Page 17
13 Drainage continued The drainage tube 1. Slide out the drain valve from the left side of th e unit. 2. Attach the drainage tube to the drain valv e. 3. Route the tubing downward so that con densate flows prop- erly into a floor drain or cond ensate line below the unit. Note: Condensation will drip through the drain valve if it is open. Make sure [...]
-
Page 18
14 Maintaining the Unit Clean the air filter APC recom mends cl eaning your air filter at least af ter every two weeks of use. Keeping your air filter clean wi ll maxim ize the perform ance and life of this product. 1. T urn off the unit and unplug it fro m its electrical ou tlet. 2. Open the air filter on the left side of th e unit. 3. Remove the [...]
-
Page 19
15 Maintaining the Unit continued Clean the condensate tank r egularly 1. T urn off the unit and unplug it fro m its electrical ou tlet 2. Using the handle, slowl y remo ve the condensate tank from the side of the unit. 3. Pour out any condensation accum ulated in the tank. 4. Clean the inside of the tank with a solution of warm water and mild dete[...]
-
Page 20
16 Maintaining the Unit continued Storing the Unit The following precauti ons must be taken when storing the unit for extended periods of tim e: 1. T urn off unit. 2. Clean the air filter and allow to air dr y before replacing in unit. 3. Empty the con densate tank. 4. Remove the stopper fr om the water drain pipe and drain until empty . Reinsert t[...]
-
Page 21
17 T r oubleshooting T ry th is first Problem Cause Suggestion Unit does not work Unit is not plugged in. Securely plug receptacle into the wall. Main power is off. Check fuse or circuit breaker Condensate tank is full. Indicator light is on. Empty tank. Poor cooling perfo rmanc e. Air exhaust or intake blocked. Clear all obje cts away from air gri[...]
-
Page 22
18 T r oubleshooting continued T ry th is first, continued Problem Cause Suggestion W ater is leaking from unit. Drain tube is clogged. Remove blockage. Condensate tank is improperly seated. Reposition t ank. Surface not level. Place unit on a level surface away from obstructions. Damaged condensate tank. Replace tank. Stopper on water drain pipe i[...]
-
Page 23
19 T r oubleshooting continued If pr oblems persist For problem s not covered in the troubleshooting char t, or if the problem persi sts, follow this procedure: 1. Note the serial number and date of purchase of the NetworkAIR 1000. Contact Custom er Supp ort at a phone number or addr ess on the back cover of this manual. 2. Be prepared to provide a[...]
-
Page 24
20 W arranty Information Limited warranty American Power Conversion (APC) war rants the NetworkAir 1000 to be free from d efects in m aterials and workmanship for a period of one year from the date of purchase. Its obligation under thi s warranty is lim ited to repairing or replacing, at its own sole opt ion, any such defec- tive products. Thi s wa[...]
-
Page 25
21 Specifications Item Specification AP7003 AP7004 Electric al Power source 1 15 V ; 60 Hz 230 V ; 50 Hz Rated current 6.2 A 3.6 A Rated input Cooling 692 W Dehumidify 660 W Cooling 860 W Dehumidify 820 W Physica l Condensate T ank capacity 3.5 qt (3 .3 L) 3.5 qt (3.3 L) Physical di mensions 12.85 × 16.250 × 30.75 in (326 × 415 × 788 mm) 12.85 [...]
-
Page 26
[...]
-
Page 27
[...]
-
Page 28
APC W orldwide Customer Support Customer support for this or any other APC product is available at no charge in an y of the following ways: • V isit the APC W eb site to find answers to frequently asked questions (F AQs), to access documents in the APC knowledge base, and to submit cus- tomer support requests. – http://www .apc.com (Corporate H[...]